In-Situ FTIR Gas Analyzer
2Pages

{{requestButtons}}

Catalog excerpts

In-Situ FTIR Gas Analyzer - 1

In-Situ Multicomponent FTIR Gas Analyser Max. air consumption: 250 l/min for vortex cooling (cont.) 100 l/min for zero calibration/purge (15 minutes at 24 hour intervals) Gasmet FTIR In-Situ is industrial multicomponent gas analysers for continuous monitoring applications. The Gasmet In-Situ incorporates a Fourier transform infrared spectrometer, a sample cell which is directly inserted into the sample gas flow, and signal processing electronics. The analyser is fully equipped for fixed installations and it offers versatility and high performance for a wide range of applications. In-Situ analyser is equipped with a control box providing gas and electrical connections, and an external computer unit. The computer employs the same Calcmet user interface as an extractive Gasmet CEMS. The sample must be non-condensing and the upper limit for sample temperature is 250 oC. Sample cell absorption path length is 6.0 meters. Insertion depth of the sample probe is 736 mm and the flange diameter is 240 mm. Scan frequency: Detector: Source: Beamsplitter: Window material: Wave number range: 10 scans / s Peltier cooled MCT Ceramic SiC, at 1550 K ZnSe ZnSe 900 - 4 200 cm'1 Sample cell General parameters Measuring principle: Performance: Response time, T90: Fourier transform infrared, FTIR Simultaneous analysis of up to 50 gas compounds Typically < 360 s, depending on the gas flow and measurement time Operating temperature: Storage temperature: Power supply: Power consumption: Instrument air: -30 - +40 °C, non-condensing -30 - +60 °C, non-condensing 100-115 or 230 V / 50-60 Hz 2200 W max., 500 W continuous (with cell heating) 4-7 bar pressure, dew point -20 oC, oil and dust free Structure: Probe body material: Mirror material: Mirror coating: Gaskets: Window material: Insertion depth Mounting flange Temperature Gas filtration Multi-pass, fixed path length 6.0 m AISI 316 steel Rhodium coated aluminium Reflective gold coating Viton® O-rings BaF2 736 mm 240 mm diameter 250 °C Filter panels (2-7 gm) Measuring parameters Zero point calibration: 24 hours, calibration with Zero point drift: < 2 % of measuring range per zero STREET ADDRESS: Pulttitie 8 A 1 00880 Helsinki, Finland

Open the catalog to page 1
In-Situ FTIR Gas Analyzer - 2

Sensitivity drift: Linearity deviation: Temperature drifts: Pressure influence: point calibration interval None < 2 % of measuring range < 2 % of measuring range per 10 K temperature change 1 % change of measuring value for 1 % sample pressure change. Sample pressure changes are measured and compensated Options Adapters for flanges larger than 240 mm RS-422/485 interface instead of RS-232 for longer distance, maximum distance one (1) kilometer. Enclosure Sample gas conditions Gas temperature: Up to 250 oC, non-condensing Material: Dimensions (mm): Weight: CE label: Aluminium / steel /...

Open the catalog to page 2

All Gasmet Technologies catalogs and technical brochures

  1. gasmet_cems

    2 Pages

  2. DX4015

    2 Pages