FTIR Process Gas Analyzer The Gasmet FCX-Series features a comprehensive range of high performance FTIR process gas analyzers. The wall mounted Gasmet FCX process gas analyzers offer reliable results even when analyzing complex gas mixtures. The Gasmet FCX process gas analyzers incorporates a Fourier Transform Infrared spectrometer, gas cell, and signal processing electronics, a built-in Industrial Computer and a TFT display into a compact enclosure. The analysis results of Gasmet FCX process gas analyzer are transmitted via 4-20 mA analog output signals or digital outputs (ModBus) The enclosure has IP 65 protection and the analyser is equipped with Vortex cooling system. The sample cell can be equipped with an optional heating and temperature control up to 180 °C. Sample cell absorption path length is selected according to the application. Spectrometer Resolution: Scan frequency: IR source: Detector: Beamsplitter: Window material: Wave number range: Sample cell General parameters Measuring principle: Number of components: Response time, T90: Operating temperature: Climate control: Storage temperature: Power supply: Power consumption: Fourier transform infrared, FTIR 1 - 50 components < 120 s, depending on the gas flow and measurement time 5 - 30 °C, non-condensing Vortex -20 - 60°C, non-condensing 100-115 or 230 V / 50-60 Hz 500 W Structure: Standard materials: Connectors: Sample cell gaskets: Temperature: Multi-pass or single pass cells. Available from 1 cm up to 9.8 m Stainless Steel or 100 % gold or rhodium coated aluminium Inlet Swagelok 6 mm Outlet Swagelok 8 mm Optional %” Viton®. Kalrez® available upon special request 180 °C, maximum Window material: BaF2 or ZnSe or AR coated ZnSe Measuring parameters Zero point calibration: Zero point drift: 24 hours, calibration with nitrogen (5.0 or higher N2 recommended) < 2 % of measuring range per zero STREET ADDRESS: Pulttitie 8 A1 00880 Helsinki, Finland
Open the catalog to page 1point calibration interval Sensitivity drift: None Linearity deviation: < 2 % of measuring range Temperature drifts: < 2 % of measuring range per 10 K temperature change Pressure influence: 1 % change of measuring value for 1 % sample pressure change. Ambient pressure changes measured and compensated Air conditioning Gas inlet and outlet conditions Gas temperature: Flow rate: Gas filtration: Sample gas pressure: Non-condensing, the sample gas temperature should be the same as the sample cell temperature 120 - 600 liters per hour Filtration of particulates (2 pm) required Ambient...
Open the catalog to page 2All Gasmet Technologies catalogs and technical brochures
-
gasmet_dx4040
2 Pages
-
gasmet industrial computer
2 Pages
-
gasmet cems ii
2 Pages
-
gasmet mercury monitoring
3 Pages
-
gasmet_cems
2 Pages
-
gasmet_oxygen_analyzer
2 Pages
-
In-Situ FTIR Gas Analyzer
2 Pages
-
Portable Calibrator
2 Pages
-
gasmet_cems_ii
2 Pages
-
gasmet_cx4000
2 Pages
-
stack_testing
2 Pages
-
gasmet_portable_sampling
2 Pages
-
DX4015
2 Pages
-
gasmet_heated_sampling_lines
1 Pages
-
Portable Sampling Unit
2 Pages
-
gasmet_dx4000_web
2 Pages