Product catalog summary
Overview
The document discusses the use of the Gasmet DX4040 portable multi-gas analyser for the remediation and cleaning of contaminated sites, particularly when converting old industrial areas to residential or commercial use. It focuses on measuring volatile organic compounds (VOCs) and chlorinated compounds that may have leaked into the ground.

Specifications
The Gasmet DX4040 can simultaneously analyze up to 25 gases with sub-ppm detection limits and high accuracy. It uses Fourier Transform Infrared (FTIR) gas analysis, which is non-destructive, allowing the sample to be returned to the borehole to maintain equilibrium. The device provides continuous, real-time results with time-weighted averaging, typically between 5 to 60 seconds, and reaches 90% of the target concentration in approximately two minutes.

Procedures
The analyser samples the headspace of boreholes drilled into the ground. For survey measurements, the sample gas does not need to be returned to the borehole, allowing for rapid coverage of multiple test points. Results are displayed on a PDA via Bluetooth, and the device requires no span calibrations, only a simple zero in clean ambient air.

Typical Gases Measured
The document lists several compounds with their detection ranges and limits, including Benzene, Toluene, p-Xylene, Trichloroethylene (TCE), and others. The limit of detection is calculated as three times the standard deviation of baseline noise over a 60-second averaging time.

Data Interpretation
Figure 3 illustrates a sample spectrum from a borehole and reference spectra for expected gases. The FTIR method can distinguish between similar molecules, including isomers, with high accuracy.

Recommendations
This application note serves as an informative example of typical applications for Gasmet analyzers. It is not a technical specification sheet, and optimal product configuration is application-dependent. For specific needs, contacting a local Gasmet sales representative is recommended.
See more

Catalog excerpts

contaminated_site_measurements-1

GasmetTM FTIR application note Contaminated site measurements KEY WORDS • Remediation of contaminated sites • Volatile organic compounds (VOCs) • Chlorinated compounds OVERVIEW Remediation and cleaning of contaminated sites is necessary when old industrial areas are converted to residential or commercial use. Aromatic and Chlorinated volatile organic compounds (VOCs) and other toxic substances may have leaked into the ground, necessitating measurements in order to determine the identity of pollutant, extent of spill and the pollutant concentration in the ground. The Gasmet DX4040 portable multi-gas analyser can achieve this by sampling the headspace of boreholes drilled into the ground. As FTIR (Fourier Transform Infrared) gas analysis is non-destructive, the sample can be extracted from the borehole, circulated through the analyser, and returned to the hole so that equilibrium is formed between the ground and the air in the borehole. Simultaneous analysis of up to 25 gases with subppm detection limits and high accuracy make the DX4040 an ideal tool for this purpose. Additionally, when a gas that is not included in the 25 Figure 1 Contaminated ground site being measured Copyright Gasmet Technologies Oy 2012 PRODUCTS • DX4040 Portable FTIR Gas Analyzer component list is present, its infrared spectrum can be compared against a larger library with a laptop computer and the unknown gas can be identified. Alternatively, if only a survey measurement for the presence of certain pollutants is required, the analyser can be operated without returning the sample gas to the borehole. In this way the operator can cover a large number of test points in a short period of time. The measurements are continuous, real time results with time weighted averaging. Typical averaging periods are from 5 to 60 seconds and the instrument takes approximately two minutes to reach 90% of the target concentration (T90 < 120 seconds). The DX4040 gas analyzer results are displayed on a PDA via bluetooth wireless communication. No span calibrations are required and the DX4040 is fully operational after a simple zero in clean ambient air. Figure 2 Gasmet DX4040 portable gas anal

 Open the catalog to page 1
contaminated_site_measurements-2

TYPICAL GASES MEASURED AT CONTAMINATED REMEDIATION SITES Compound name Benzene Toluene p-Xylene Trichloroethylene (TCE) 1,1-Dichloroethylene cis-Dichloroethylene Perchloroethylene (PCE) Dichloromethane (DCM) Chloroform Methane Ethyl Chloride * Limit of detection is calculated as 3 x standard deviation of baseline noise, 60 second averaging time. Other ranges and compounds available; please contact Gasmet Technologies for further details Figure 3 Sample spectrum from borehole and reference spectra for expected gases. Methane and cis*Dichloroethylene are present, whereas trans*-dichloroethylene...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.