WOB-L™ Piston Air Compressors and Vacuum Pumps - 1

WOB-L™ Piston Air Compressors and Vacuum PumpsMODELS 8003 8005 8006 8009 FEATURES • Service free and oil-less • Compact design • Balanced for smooth, low vibration operation • Suitable for continuous running • Wetted parts - Series 8003/8005/8006 heat resistant high performance plastic, Elastomer valves - Series 8009 corrosion resistant aluminium parts, stainless steel valves - Long-life, high performance piston seal (PTFE compound) TYPICAL APPLICATIONS • Medical industry • Laboratory and Analysis technology • Automotive • Equipment manufacturing Consult factory for customized solutions

Open the catalog to page 1
WOB-L™ Piston Air Compressors and Vacuum Pumps - 2

Flow 3,0 l/minMax. pressure 2,0 bar OIL-lfSS Pneumatic Data All listed values measured at standard atmospheric conditions. Flow Curves D = Pressure E = EPDM Motor type 8003... Stock programme Option: Low cost DC-motor The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability...

Open the catalog to page 2
WOB-L™ Piston Air Compressors and Vacuum Pumps - 3

Flow 4,3 l/minMax. pressure 2,0 bar OIL-lfSS Electrical Data Motor type_Brushless DC_ Drive electronics_integrated with reverse supply voltage protection Motor insulation class_B_ Port direction D Flow Curves vs. Speed Control Input Wetted Parts Pump head PAA (IXEF) Cylinder sleeve PPS Piston sealing PTFE Valves EPDM Eccentric Motor type Type Valves The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It...

Open the catalog to page 3
WOB-L™ Piston Air Compressors and Vacuum Pumps - 4

WOB-L Piston Compressor 8003ZDP DC 5,4 l/min 2,0 bar Pneumatic Data Description Part number 12 V DC Max. flow Max. pressure Max. continuous pressure Max. restart pressure Electrical Data otor type M ominal voltage N ominal speed N ower consumption P otor insulation class M General Data mbient temperature A Media temperature Weight Port direction Configuration All listed values measured at standard atmospheric conditions. Flow Curves Model key: Z = Double head E = EPDM D = Pressure P = Parallel Motor type The information presented in this material is based on technical data and test results...

Open the catalog to page 4
WOB-L™ Piston Air Compressors and Vacuum Pumps - 5

Flow 3,0 l/minMax. vacuum 59 % OIL-lfSS Pneumatic Data All listed values measured at standard atmospheric conditions. Flow Curves Stock programme V = Vacuum E = EPDM Motor type Option: Low cost DC-motor The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability whatsoever in connection...

Open the catalog to page 5
WOB-L™ Piston Air Compressors and Vacuum Pumps - 6

Electrical Data Motor type_Brushless DC_ Drive electronics_integrated with reverse supply voltage protection Motor insulation class_B_ Port direction D Flow Curves vs. Speed Control Input Wetted Parts Pump head PAA (IXEF) Cylinder sleeve PPS Piston sealing PTFE Valves EPDM Eccentric Motor type Type Valves The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the...

Open the catalog to page 6
WOB-L™ Piston Air Compressors and Vacuum Pumps - 7

Electrical Data Motor type_Direct current_Direct current Motor insulation class E E General Data Ambient temperature Media temperature Weight Port direction Configuration_ All listed values measured at standard atmospheric conditions. Z = Double head V = Vacuum R = Series The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended...

Open the catalog to page 7
WOB-L™ Piston Air Compressors and Vacuum Pumps - 8

Electrical Data Motor type Nominal voltage Nominal speed Power consumption Motor insulation class Direct current Direct current General Data Ambient temperature_10 to 40 °C_10 to 40 °C_ Motor type Option: Noise reduced head Brushless DC-motor The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and...

Open the catalog to page 8
WOB-L™ Piston Air Compressors and Vacuum Pumps - 9

Pneumatic Data Max. continuous pressure Max. restart pressure Electrical Data Motor type Nominal voltage Nominal speed Power consumption Motor insulation class Thermal switch General Data Ambient temperature_10 to 40 °C_10 to 40 °C Port direction_A_A_ All listed values measured at standard atmospheric conditions. Flow Curves Motor type The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the...

Open the catalog to page 9
WOB-L™ Piston Air Compressors and Vacuum Pumps - 10

Electrical Data Motor type_Direct current_Direct current Motor insulation class E E General Data Ambient temperature_10 to 40 °C_10 to 40 °C_ Port direction_D_D_ * Due to a difference in nominal speeds the 24 V DC units have a 10% reduced flow rate when compared to the 12 V DC units. All listed values measured at standard atmospheric conditions. Flow Curves V = Vacuum Motor type Option: Noise reduced head Brushless DC-motor The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered...

Open the catalog to page 10

All Gardner Denver Thomas catalogs and technical brochures

  1. 660 Series

    3 Pages

  2. 7011 Series

    4 Pages

  3. 7006 Series

    12 Pages

  4. QR SERIES

    3 Pages

  5. SR Series

    20 Pages

  6. 380 Series

    3 Pages

  7. 2110Z Series

    3 Pages

  8. F120 Series

    4 Pages

  9. 5002F

    6 Pages

  10. 1610 Series

    4 Pages

  11. 118 SERIES

    2 Pages

Archived catalogs

  1. LMF SERIES

    6 Pages

  2. 319 Series

    2 Pages

  3. 260 Series

    2 Pages

  4. 617 Series

    2 Pages

  5. 2520 Series

    3 Pages

  6. 2250 Series

    2 Pages

  7. 2220 Series

    2 Pages

  8. 215 Series

    2 Pages

  9. 415 Series

    2 Pages

  10. 309 Series

    3 Pages

  11. 405 Series

    3 Pages

  12. 415Z

    2 Pages

  13. 135 Series

    2 Pages

  14. 520 Series

    3 Pages

  15. 115 Series

    2 Pages

  16. 014 Series

    3 Pages

  17. 500 Series

    2 Pages

  18. 010 Series

    3 Pages

  19. 230 Series

    2 Pages

  20. 800X Series

    23 Pages