Catalog excerpts
Peristaltic Pumps BASE MODEL >>Compact design >>Quick change of cassette (SR10)/tubing (SR25, SR18) >>Endless tubing possible (SR10) >>Self priming >>Maintenance free >>Different tubing materials TYPICAL APPLICATIONS >>Chemical industry >>Medical industry >>Laboratory and analysis technology >>Food sector >>Hygiene, desinfection >>Industrial dishwasher >>Glass washing
Open the catalog to page 1Peristaltic Pumps CHARACTERISTICS OVERVIEW SR10/30 DC Stepper motor SR25 DC AC, synchronous motor AC, shaded polemotor Stepper motor 0 Flow (ml/min) Stand-by pump Short time operation Continuous operation Stepper motor Operation mode pumps with sequencer
Open the catalog to page 2Peristaltic Pumps SERIES SR10 • Speed reduction through frictional connection from the motor shaft to the rollers. • Very simple construction with the use of few parts only. • Easy change of the cassette. • Generally 3 rollers. • For short time operation only. • the pump is stored longer than three months, If we recommend to take the cassette off the motor shaft and store it separately. • Different motors available (DC, low cost DC, AC and stepper motor). Tubing Rollers Pump body • Peristaltic pump with QuiXchange system • Tube exchange without tooling within seconds • Spring loaded roller...
Open the catalog to page 3Peristaltic Pumps DUTY CYCLES SR10/100 Drive: Capacitormotor Permanent magnet motor (DC) SR10/30 and SR10/50 Drive: Permanent magnet motor (DC) 5 10 15 min. idle time in minutes 5 10 15 20 min. idle time in minutes SR18 Drive: Synchronous motor with sequencer 6s Drive: ynchronous motor w/o S sequencer 5 10 15 20 min. idle time in minutes Operation time SR25 Drive: Synchronous motor Drive: Shaded pole motor (AC) Drive: Permanent magnet motor (DC) suitable for continuous operation 60 1 20 min. idle time in minutes 60 1 20 min. idle time in minutes 5 10 15 20 min. idle time in minutes DUTY...
Open the catalog to page 4Peristaltic Pumps SR10/30 12/24 V low cost DC For short time operation only (straight without drawing) Tubing PharMed BPT ® 12 V DC Current consumption depending on the tubing diameter, at free flow and nominal voltage 12 V DC: 180 – 300 mA 24 V DC: 90 – 150 mA Stock programme 2) Note: The indicated values are average measured with water. The actual values depend on different parameters like quality and age of tubing, pressure of tubing beds, pressure ratios, viscosity. Please see page 4 for recommended running times and general data.
Open the catalog to page 5Peristaltic Pumps SR10/30 12/24 V Direct current motor For short time operation only 1) other tubing materials on request Current consumption depending on the tubing diameter, at free flow and nominal voltage 12 V DC: 180 – 300 mA 24 V DC: 90 – 150 mA 2) Note: The indicated values are average measured with water. The actual values depend on different parameters like quality and age of tubing, pressure of tubing beds, pressure ratios, viscosity. Please see page 4 for recommended running times and general data.
Open the catalog to page 6Peristaltic Pumps SR10/30 24 V DC with stepper motor For short time operation only Circuit board recommended for test purposes 0.5 – 20 ml/min SR25 / F120 yellow red blue orange Item Nr. Motor pulse/rev rot.speed n1 n2 n3 n4 SR10/30 black brown yellow orange Features • speed pre-selection • clockwise-, counter clockwise operation • instant priming • selective operating method cw / ccw connector open = cw setpoint indication Max. flow 2) ml/min (adjustable range 4 – 100%) 0.5 Part number – pump with circuit board Part number – pump without circuit board Part number – pump with circuit board...
Open the catalog to page 712/24 V Direct current motor For short time operation only Tubing PharMed BPT ® Tubing dimensions Tubing Silicon Tubing PharMed BPT ® 12 V DC Tubing dimensions Stock programme 1) on request in white Option: traight flange for flush mounting part number 20501 ... S 12/24 V DC – with additional circuit board (on request) Current consumption depending on the tubing diameter, at free flow and nominal voltage 12 V DC: 0.4 – 0.54 A 24 V DC: 0.2 – 0.27 A 2) Note: The indicated values are average measured with water. The actual values depend on different parameters like quality and age of tubing,...
Open the catalog to page 8Peristaltic Pumps SR10/100 230 V/50 Hz, 12/24 V Direct current motor For short time operation only 1300 – 3000 ml/min blau (blue) braun (brown) 150•C150±5K 27.5 (1.08) Montagewinkel entfällt bei Ausführung -Schottmontage- balkhead insertion is without bracket flush mount Tubing Norprene® Motor speed Tubing dimensions 1) other tubing material on request Option: ecommended inference suppression according to EN 55011 B (CE-conform) R 12/24 V DC – with additional circuit board (on request) Current consumption at free flow and nominal voltage 2) Note: The indicated values are average measured...
Open the catalog to page 9Peristaltic Pumps SR10 Spare parts SR10 series Tubing Inner Ø x Wall thickness PharMed BPT® PharMed BPT® PharMed BPT® PharMed BPT® PharMed BPT® Wall thickness
Open the catalog to page 10Peristaltic Pumps SR18 with QuiXchange System 230 V/50 Hz, synchronous gear motor Suitable for continuous running 5 – 50 ml/min Sequencer to adjust on/off-time (0% – 100%) Tubing QuiXchange Nominal speed Tubing only Part number – pump without sequencer Part number – pump with sequencer Part number – pump without sequencer Part number – pump with sequencer Part number – pump without sequencer Part number – pump with sequencer Part number – pump without sequencer Part number – pump with sequencer Tubing only Part number – pump without sequencer Part number – pump with sequencer Part number –...
Open the catalog to page 11Peristaltic Pumps SR25 12/24 V, Direct current motor 2 – 287 ml/min Dimensions in mm (inch) SR25, 10 to 80 rpm Direct current motor SR25 –170 rpm1) Direct current motor Bore pattern to fit in a housing see page 14. Nominal speed 10 rpm Part number 12 V Part number 24 V Part number 12 V Part number 24 V Part number 12 V Part number 24 V S 3.0 x 1.5 mm Part number 12 V Part number 24 V S 4.0 x 1.5 mm Part number 12 V Part number 24 V S 5.0 x 1.5 mm Part number 12 V Part number 24 V Electrical Data Motor Power consumption Direct current motor 2W General Data Weight 1) Pump with counter bearing...
Open the catalog to page 12All Gardner Denver Thomas catalogs and technical brochures
-
Linear Diaphragm Pump LMG 4
1 Pages
-
660 Series
3 Pages
-
7011 Series
4 Pages
-
7006 Series
12 Pages
-
SR Series Performance Data
2 Pages
-
VTE | DTE series
12 Pages
-
QR SERIES
3 Pages
-
MINIATURE series
24 Pages
-
SR Series
20 Pages
-
Continuous Inkjet Systems
8 Pages
-
Accessories Catalog
12 Pages
-
380 Series
3 Pages
-
2110Z Series
3 Pages
-
LINEAR SERIES
3 Pages
-
F120 Series
4 Pages
-
5002F
6 Pages
-
Miniature Diaphragm Pumps
11 Pages
-
1610 Series
4 Pages
-
Diaphragm Pumps
20 Pages
-
118 SERIES
2 Pages
-
Diaphragm Pumps
6 Pages
-
Linear Diaphragm Pumps
12 Pages
Archived catalogs
-
BLDC Product Overview
3 Pages
-
RotaryVanePumps
24 Pages
-
Rotary Vane Pumps
12 Pages
-
Linear DiaphragmPumps
12 Pages
-
LMF SERIES
6 Pages
-
DiaphragmLiquidPumps
8 Pages
-
910 & 2907 SERIES
2 Pages
-
319 Series
2 Pages
-
260 Series
2 Pages
-
617 Series
2 Pages
-
2520 Series
3 Pages
-
2250 Series
2 Pages
-
2220 Series
2 Pages
-
215 Series
2 Pages
-
415 Series
2 Pages
-
309 Series
3 Pages
-
405 Series
3 Pages
-
415Z
2 Pages
-
135 Series
2 Pages
-
520 Series
3 Pages
-
115 Series
2 Pages
-
014 Series
3 Pages
-
500 Series
2 Pages
-
010 Series
3 Pages
-
230 Series
2 Pages
-
800X Series
23 Pages
-
Peristaltic Pumps Catalog
20 Pages