Peristaltic Pumps MODELS SR10/30 SR10/50 SR10/100 SR18 SR25 SR18 SR10/30 SR25 FEATURES TYPICAL APPLICATIONS • Compact design • Quick change of cassette (SR10)/ tubing (SR25, SR18) • Endless tubing possible (SR10) • Self priming • Safe to run dry • Maintenance free • Different tubing materials • Chemical industry • Medical industry • Laboratory and analysis technology • Food sector • Hygiene, desinfection • Industrial dishwasher • Glass washing

Open the catalog to page 1
Peristaltic Pumps Catalog - 2

Peristaltic Pumps Characteristics overview Flow (ml/min) " pumps with sequencer A Gardner Denver Product

Open the catalog to page 2
Peristaltic Pumps Catalog - 3

Peristaltic Pumps Series SR10 • Speed reduction through frictional connection from the motor shaft to the rollers. • Very simple construction with the use of few parts only. Motor • Easy change of the cassette. • Generally 3 rollers. Bracket • For short time operation only. • If the pump is stored longer than three months, we recommend to take the cassette off the motor shaft and store it separately. Lid Tubing Drawing 13440 • Different motors available (DC, low cost DC, AC and stepper motor). Rollers Pump body Series SR18 • Peristaltic pump with QuiXchange system • Tube exchange without...

Open the catalog to page 3
Peristaltic Pumps Catalog - 4

Peristaltic Pumps Duty cycles SR10 15 10 Laufzeit in min. 5 1 2 3 Laufzeit in min. 15 10 20 SR10/100 Drive: Capacitor Permanent magnet motor (DC) 4 SR10/30 and SR10/50 Drive: Shaded pole motor (AC) 5 Laufzeit in min. SR10/30 and SR10/50 Drive: Permanent magnet motor (DC) 5 10 15 Mindestpausenzeit in min. 5 10 15 20 Mindestpausenzeit in min. 20 40 60 Mindestpausenzeit in min. SR18 Drive: Synchronous motor w/o sequencer Drive: Synchronous motor with sequencer 6s 15 Flow 20 6s t 10 Operation time 6s 6s Flow 6s 5 Laufzeit in min. 6s t 5 10 15 20 Mindestpausenzeit in min. Operation time 6s 6s...

Open the catalog to page 4
Peristaltic Pumps Catalog - 5

Peristaltic Pumps SR10/30 230 V/50 Hz, 12/24 V low cost DC For short time operation only 16 – 55 ml/min Drawing 2030KA01-04-00 Inches are shown in ( ) (straight without drawing) Interference suppression according to EN 55011 B (CE-conform) Tubing Novoprene 24 V DC 230/50 Hz 20300314 20300315 20300316 20300317 20300318 20300319 20300344 20300345 20300346 20300347 20300348 20300349 12 V DC 20300412 20300413 20300414 20300415 20300416 20300417 20300418 20300419 Tubing Silicon 24 V DC 20300442 20300443 20300444 20300445 20300446 20300447 20300448 20300449 20300362 Tubing PharMed BPT® 12 V DC 24...

Open the catalog to page 5
Peristaltic Pumps Catalog - 6

12/24 V Direct current motor For short time operation only Straight flange Hern eotetcn Angled flange Current consumption depending on the tubing diameter, at free flow and nominal voltage 12 V DC: 160 - 260 mA 2) Note: The indicated values are average measured with water. The actual values depend on different parameters like quality and age of tubing, pressure of tubing beds, pressure ratios, Please see page 4 for recommended running times and general data. A Gardner Denver Product

Open the catalog to page 6
Peristaltic Pumps Catalog - 7

Peristaltic Pumps SR10/30 24 V DC with stepper motor For short time operation only Circuit board recommended for test purposes 0,5 – 20 ml/min Drawing 2030KA02-04-00 Inches are shown in ( ) Flow Weight 0,08 kg X3/4 X 3,6 (0,14) SR25 / F120 yellow red blue orange 29004320 Item Nr. Motor pulse/rev rot.speed n1 n2 n3 n4 pin assignment X3 X3/1 X3/2 X3/3 SR10/30 black brown yellow orange 29004319 SR10/30 SR25 384 F120 1600 rpm rpm 2 ...100 4 ...210 8 ...430 20 ...900 0,2 ...10 0,8 ...40 3 ...150 6 ...300 24 V = or on / off 20 V ~ 50 42 (1,6 (2) 5) 0.5A ) 15 8) (3, 2 (2, 80 7 UB +/-/+ X1 14 13...

Open the catalog to page 7
Peristaltic Pumps Catalog - 9

Peristaltic Pumps SR10/100 230 V/50 Hz, 12/24 V Direct current motor For short time operation only 99 (3.90) 72 (2.83) 112 (4.41) 105 (4.12) 110 (4.33) 107 (4.22) E CLOS 50 (1.97) ¯ 15 (.59) 63 (2.48) 109 (4.31) 30 Z U 57 (2.28) 63 (2.48) schwarz (black) M ~ blau (blue) braun (brown) Weight 1,7 kg 150•C150±5K 26.5 (1.04) 72 (2.83) 77.5 (3.05) CLOSE ) ~30 (1.18) 107.5 (4.16) 112.5 (4.43) ZU pat. US 4,113,409 Litzen (wires) ( 118.5 (4.66) SR10/100 AC OPE N (1.18) Drawing 13591 Inches are shown in ( ) 54 (2.13) AUF 164 (6.46) ¯ 70 (2.76) 1300 – 3000 ml/min ~30 (1.18) Flow 300mm 1 106 (4.17) 2...

Open the catalog to page 9
Peristaltic Pumps Catalog - 10

Peristaltic Pumps Series SR10 Spare parts SR10 series Tubing Inner X x Wall thickness Model Drive DC low cost DC + AC Page 5 Pages 5, 6, 7 SR10/30 1,5 x 1,0 mm 2,0 x 1,0 mm 2,5 x 1,0 mm 92030703 92030702 92030701 92030514 92030513 92030704 PharMed BPT® PharMed BPT® PharMed BPT® 1,0 x 1,1 mm 1,5 x 1,1 mm 2,5 x 1,0 mm 92030548 92030534 92030611 92030604 92030549 92030603 Silicon Silicon Silicon Silicon 1,0 x 1,0 mm 1,5 x 1,0 mm 2,0 x 1,0 mm 2,5 x 1,0 mm 92030800 92030802 92030804 92030806 92030505 92030554 92030555 92030553 Novoprene Novoprene Novoprene 2,4 x 1,6 mm 3,2 x 1,6 mm 4,1 x 1,6 mm...

Open the catalog to page 10
Peristaltic Pumps Catalog - 11

Peristaltic Pumps SR18 with QuiXchange System 230 V/50 Hz2), synchronous gear motor Suitable for continuous running 5 – 50 ml/min Drawing 2018KA02-05-00 Inches are shown in ( ) Flow Tubing QuiXchange Features Sequencer to adjust on/off-time (0% – 100%) Tubing Novoprene (ID x WT) N 6,0 x 1,6 mm Part number – pump without sequencer Part number – pump with sequencer N 4,1 x 1,6 mm Part number – pump without sequencer Part number – pump with sequencer N 2,4 x 1,6 mm Part number – pump without sequencer Part number – pump with sequencer N 1,6 x 1,6 mm Part number – pump without sequencer Part...

Open the catalog to page 11
Peristaltic Pumps Catalog - 12

12/24 V, Direct current motor Direct current motor Direct current motor Bore pattern to fit in a housing see page 14. 1) Pump with counter bearing Material of tubing connectors: Option: Recommended inference suppression according to EN 55011 B (CE-conform) 12/24 V DC-with additional circuit board (on request) Stock programme 2) Note: The indicated values are average measured with water. The actual values depend on different parameters like quality and age of tubing, pressure of tubing beds, pressure ratios. Please see page 4 for recommended running times and general data. A Gardner Denver...

Open the catalog to page 12

All Gardner Denver Thomas catalogs and technical brochures

  1. 660 Series

    3 Pages

  2. 7011 Series

    4 Pages

  3. 7006 Series

    12 Pages

  4. QR SERIES

    3 Pages

  5. SR Series

    20 Pages

  6. 380 Series

    3 Pages

  7. 2110Z Series

    3 Pages

  8. F120 Series

    4 Pages

  9. 5002F

    6 Pages

  10. 1610 Series

    4 Pages

  11. 118 SERIES

    2 Pages

Archived catalogs

  1. LMF SERIES

    6 Pages

  2. 319 Series

    2 Pages

  3. 260 Series

    2 Pages

  4. 617 Series

    2 Pages

  5. 2520 Series

    3 Pages

  6. 2250 Series

    2 Pages

  7. 2220 Series

    2 Pages

  8. 215 Series

    2 Pages

  9. 415 Series

    2 Pages

  10. 309 Series

    3 Pages

  11. 405 Series

    3 Pages

  12. 415Z

    2 Pages

  13. 135 Series

    2 Pages

  14. 520 Series

    3 Pages

  15. 115 Series

    2 Pages

  16. 014 Series

    3 Pages

  17. 500 Series

    2 Pages

  18. 010 Series

    3 Pages

  19. 230 Series

    2 Pages

  20. 800X Series

    23 Pages