Catalog excerpts
COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions
Open the catalog to page 1INTRODUCTION / TABLE OF CONTENTS Pump and Compressor Solutions for OEMs Worldwide As the leader in providing fluidic solutions to Original Equipment Manufacturers, Thomas continues to develop new products to meet the requirements of evolving markets and applications. Breadth of product, proprietary technologies and global manufacturing benefit our customers. These distinctions coupled with innovative research and development programs, qualify Thomas as the premier resource utilized by OEMs throughout the world.
Open the catalog to page 2Performance Range The extensive product line presented in this catalog offers custom solutions configured to meet specific requirements. Flow Pressure Vacuum Liquid The flow range extends to 22.1 cfm (625 l/min). The pressure range extends to 175 psi (12 bar). The vacuum range extends to 99% of local barometer (10 mbar abs). Thomas pumps cover a flow range to 3 l/min and pressures to 60 m H2O. These pumps are self-priming and can also be used for dosing applications. Series Selection Model Selection
Open the catalog to page 3Technology Selection > D Series Selection > \^ Model Selection WOB-L® PISTON Oil-less WOB-L® piston pumps and compressors. Best choice for pressure and/or vacuum applications that require compact, lightweight designs and high performance piston seals. Free flow: to 7.1 cfm (200 l/min) Pressure: to 160 psi (11 bar) Vacuum: to 99% local barometer ROTARY VANE Oil-less and self-lubricating rotary vane pumps and compressors. Low vibration, nearly pulsation free, compact and in some cases reversible flow operation. Free flow: to 10 cfm (283 lpm) Pressure: to 14.5 psi (1 bar) Vacuum: to 93% local...
Open the catalog to page 4Technology Selection > D Series Selection > w Model Selection Series Selection THOMAS by Gardner Denver WOB-L Piston Page 10 MODEL SERIES DC or BLDC AC or DC BLDC DC AC or DC BLDC DC AC or DC DC DC AC DC or BLDC DC BLDC AC or DC BLDC BLDC AC AC DC AC BLDC AC AC or BLDC AC AC AC AC AC AC BLDC AC AC AC AC AC WOB-L Refrigerant Recovery Page 16 MODEL SERIES
Open the catalog to page 5Technology Selection > D Series Selection > \^ Model Selection Series Selection Articulating Piston Page i6 1 FREEFLOW MODEL SERIES MAXIMUM VACUUM MAXIMUM PRESSURE AC or DC DC AC, DC or BLDC DC or BLDC DC AC or DC DC DC AC, DC or BLDC AC AC DC AC or DC BLDC AC DC AC AC AC AC
Open the catalog to page 6Technology Selection > D Series Selection > w Model Selection Series Selection THOMAS by Gardner Denver Rotary Vane Page 22 MODEL SERIES DC or BLDC DC DC or BLDC DC DC BLDC DC DC DC DC DC AC or DC AC AC or DC AC or DC AC or DC AC
Open the catalog to page 7Technology Selection > D Series Selection > \^ Model Selection
Open the catalog to page 8Technology Selection > D Series Selection > \^ Model Selection Series Selection THOMASby Gardner Denver n
Open the catalog to page 9Technology Selection > D Series Selection > Model Selection *PM = Permament Magnet, SP = Shaded Pole, PSC = Permanent Splt Capacitor , BLDC=Brushless DC Note: Minimum release quantities or regional availability may apply. Consult factory. Note: 50/60 Hz voltage - flow values listed at 60 Hz.
Open the catalog to page 10Technology Selection > D Series Selection > \^ Model Selection THOMAS by Gardner Denver MODEL MOTOR CAPACITY FLOW MAX. VACUUM DIMENSIONS WEIGHT VOLTAGE | TYPE* 0 -100 -200 -400 -600 -800 | mbar | mm | kg *PM = Permanent Magnet, SP = Shaded Pole, PSC = Permanent Split Capacitor Note: Minimum release quantities or regional availability may apply. Consult factory. WOB-L® Piston PM = Permament Magnet, SP = Shaded Pole, PSC = Permanent Splt Capacitor , BLDC=Brushless DC Note: Minimum release quantities or regional availability may apply. Consult factory. Note:...
Open the catalog to page 11Technology Selection > D Series Selection > Model Selection *SP = Shaded Pole, PSC = Permanent Splt Capacitor , BLDC=Brushless DC, CS = Capacitor Start Note: Minimum release quantities or regional availability may apply. Consult factory. Note: 50/60 Hz voltage - flow values listed at 60 Hz.
Open the catalog to page 12Technology Selection > D Series Selection > \^ Model Selection THOMAS by Gardner Denver WOB-L® Piston Vacuum SP = Shaded Pole, PSC = Permanent Splt Capacitor , BLDC=Brushless DC, CS = Capacitor Start Note: Minimum release quantities or regional availability may apply. Consult factory. Note: 50/60 Hz voltage - flow values listed at 60 Hz.
Open the catalog to page 13Technology Selection > D Series Selection > Model Selection *PSC = Permanent Splt Capacitor Note: Minimum release quantities or regional availability may apply. Consult factory. Note: 50/60 Hz voltage - flow values listed at 60 Hz.
Open the catalog to page 14THOMAS by Gardner Denver WOB-L® Piston Vacuum PSC = Permanent Spit Capacitor Note: Minimum release quantities or regional availability may apply. Consult factory. Note: 50/60 Hz voltage - flow values listed at 60 Hz.
Open the catalog to page 15Technology Selection > D Series Selection > Model Selection Refrigerant Recovery Pressure *RDC = Rectified DC Permanent Magnet, CS = Capacitor Start Note: Minimum release quantities or regional availability may apply. Consult factory. Note: 50/60 Hz voltage - flow values listed at 60 Hz. Articulated Piston Pressure *PM = Permanent Magnet, CS = Capacitor Start, CS/CR = Capacitor start/run, POLY = 3 Phase Note: Minimum release quantities or regional availability may apply. Consult factory.
Open the catalog to page 16THOMAS by Gardner Denver WOB-L® Refrigerant Recovery PM = Permanent Magnet, CS = Capacitor Start, CS/CR = Capacitor start/run, POLY = 3 Phase Note: Minimum release quantities or regional availability may apply. Consult factory.
Open the catalog to page 17Technology Selection > D Series Selection > Model Selection *PM = Permanent Magnet, SP = Shaded Pole, *PSC=Permanent Split Capacitor, Consult factory for 60 Hz models - minimum quantities apply. Note: Minimum release quantities or regional availability may apply. Consult factory.
Open the catalog to page 18THOMAS by Gardner Denver Diaphragm Vacuum *PM = Permanent Magnet, SP = Shaded Pole, *PSC=Permanent Split Capacitor, Consult factory for 60 Hz models - minimum quantities apply. Note: Minimum release quantities or regional availability may apply. Consult factory.
Open the catalog to page 19All Gardner Denver Thomas catalogs and technical brochures
-
Linear Diaphragm Pump LMG 4
1 Pages
-
660 Series
3 Pages
-
7011 Series
4 Pages
-
7006 Series
12 Pages
-
SR Series Performance Data
2 Pages
-
VTE | DTE series
12 Pages
-
QR SERIES
3 Pages
-
MINIATURE series
24 Pages
-
SR Series
20 Pages
-
Continuous Inkjet Systems
8 Pages
-
Accessories Catalog
12 Pages
-
380 Series
3 Pages
-
2110Z Series
3 Pages
-
LINEAR SERIES
3 Pages
-
F120 Series
4 Pages
-
5002F
6 Pages
-
Miniature Diaphragm Pumps
11 Pages
-
1610 Series
4 Pages
-
Diaphragm Pumps
20 Pages
-
118 SERIES
2 Pages
-
Diaphragm Pumps
6 Pages
-
Peristaltic Pumps Catalog
20 Pages
-
Linear Diaphragm Pumps
12 Pages
Archived catalogs
-
BLDC Product Overview
3 Pages
-
RotaryVanePumps
24 Pages
-
Rotary Vane Pumps
12 Pages
-
Linear DiaphragmPumps
12 Pages
-
LMF SERIES
6 Pages
-
DiaphragmLiquidPumps
8 Pages
-
910 & 2907 SERIES
2 Pages
-
319 Series
2 Pages
-
260 Series
2 Pages
-
617 Series
2 Pages
-
2520 Series
3 Pages
-
2250 Series
2 Pages
-
2220 Series
2 Pages
-
215 Series
2 Pages
-
415 Series
2 Pages
-
309 Series
3 Pages
-
405 Series
3 Pages
-
415Z
2 Pages
-
135 Series
2 Pages
-
520 Series
3 Pages
-
115 Series
2 Pages
-
014 Series
3 Pages
-
500 Series
2 Pages
-
010 Series
3 Pages
-
230 Series
2 Pages
-
800X Series
23 Pages
-
Peristaltic Pumps Catalog
20 Pages