WOB-L™ Piston Air Compressors and Vacuum Pumps MODELS 8003 8005 8006 8009 TYPICAL APPLICATIONS • Service free and oil-less • Compact design B • alanced for smooth, low vibration operation • Suitable for continuous running W • etted parts S – eries 8003/8005/8006 heat resistant high performance plastic, Elastomer valves S • – eries 8009 corrosion resistant aluminium parts, stainless steel valves • – ong-life, high performance piston L seal (PTFE compound) • Medical industry • aboratory and Analysis L technology • Automotive • Equipment manufacturing Consult factory for customized solutions
Open the catalog to page 1WOB-L Piston Compressor 8003D DC 3,0 l/min 2,0 bar Pneumatic Data Description 12 V DC 24 V DC Max. flow Max. pressure Max. continuous pressure Max. restart pressure Electrical Data otor type M ominal voltage N ominal speed N Power consumption Motor insulation class General Data mbient temperature A Media temperature eight W Port direction All listed values measured at standard atmospheric conditions. Flow Curves Flow [l/min] Motor type 2 1,5 1 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and...
Open the catalog to page 2WOB-L Piston Compressor 8003D BLDC 4,3 l/min 2,0 bar Pneumatic Data Description Part number 12 V DC 24 V DC Max. flow Max. pressure Max. continuous pressure Max. restart pressure Electrical Data Brushless DC Motor type Nominal speed 0..4.600 rpm Nominal voltage 12/24 V DC integrated with reverse supply voltage protection Drive electronics 8,5 W Max. power consumption Motor insulation class B Protection class IP20 Connector Housing: Molex KK 22-01-2045 Terminal: Molex KK 08-50-0031 Function Colour Wiring diagram Pin 1 V Supply Red Optional: dapter for 2-wire duty A incl. potentiometer for Pin...
Open the catalog to page 3WOB-L Piston Compressor 8003ZDP DC 5,4 l/min 2,0 bar Pneumatic Data Description Part number 12 V DC Max. flow Max. pressure Max. continuous pressure Max. restart pressure Electrical Data otor type M ominal voltage N ominal speed N ower consumption P otor insulation class M General Data mbient temperature A Media temperature eight W Port direction Configuration All listed values measured at standard atmospheric conditions. Flow Curves Model key: Z = Double head E = EPDM D = Pressure P = Parallel Motor type The information presented in this material is based on technical data and test results of...
Open the catalog to page 4WOB-L Piston Vacuum Pump 8003V DC 3,0 l/min 59 % Pneumatic Data Description 12 V DC 24 V DC Max. flow Max. vacuum Max. restart vacuum Electrical Data otor type M ominal voltage N ominal speed N ower consumption P otor insulation class M General Data mbient temperature A Media temperature eight W ort direction P All listed values measured at standard atmospheric conditions. Flow Curves V = Vacuum E = EPDM Motor type 2 1,5 1 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid...
Open the catalog to page 5WOB-L Piston Vacuum Pump 8003V BLDC 4,3 l/min 65 % Flow Final Vacuum Pneumatic Data Description Part number 12 V DC 24 V DC Max. flow Max. intermittent vacuum Max. continuous vacuum Max. restart vacuum Electrical Data Brushless DC Motor type Nominal speed 0..4.600 rpm Nominal voltage 12/24 V DC integrated with reverse supply voltage protection Drive electronics 7W Max. power consumption Motor insulation class B Protection class IP20 Connector Housing: Molex KK 22-01-2045 Terminal: Molex KK 08-50-0031 Function Colour Wiring diagram Pin 1 V Supply Red Optional: dapter for 2-wire duty A incl. potentiometer...
Open the catalog to page 6WOB-L Piston Vacuum Pump 8003ZVR/ZVP DC 5,4 l/min 80 % Pneumatic Data Description Part number 12 V DC Max. flow Max. vacuum Max. restart vacuum Electrical Data otor type M ominal voltage N ominal speed N ower consumption P otor insulation class M General Data mbient temperature A Media temperature eight W ort direction P Configuration All listed values measured at standard atmospheric conditions. Model key: Z = Double head E = EPDM V = Vacuum R = Series Motor type The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate...
Open the catalog to page 7WOB-L Piston Compressor 8005D DC 7,2 l/min 2,5 bar Pneumatic Data Description Part number 12 V DC 24 V DC* Max. flow Max. pressure Max. continuous pressure Max. restart pressure Electrical Data otor type M ominal voltage N ominal speed N ower consumption P otor insulation class M General Data mbient temperature A edia temperature M Weight Port direction Due to a difference in nominal speeds the 24 V DC units have a 10% reduced flow rate when compared to the 12 V DC units. * All listed values measured at standard atmospheric conditions. The information presented in this material is based on technical...
Open the catalog to page 8WOB-L Piston Compressor 8005D AC 6,0 l/min 2,5 bar Pneumatic Data Description Part number 230 V/50 Hz Max. flow Max. pressure Max. continuous pressure Max. restart pressure Electrical Data otor type M ominal voltage N ominal speed N ower consumption P otor insulation class M hermal switch T General Data mbient temperature A Media temperature Weight Port direction All listed values measured at standard atmospheric conditions. Flow Curves 4 3 2 The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and...
Open the catalog to page 9WOB-L Piston Vacuum Pump 8005V DC 7,2 l/min 78 % Pneumatic Data Description Part number 12 V DC 24 V DC* Max. flow Max. vacuum Max. restart vacuum Electrical Data Motor type ominal voltage N ominal speed N ower consumption P otor insulation class M General Data mbient temperature A edia temperature M Weight Port direction Due to a difference in nominal speeds the 24 V DC units have a 10% reduced flow rate when compared to the 12 V DC units. * All listed values measured at standard atmospheric conditions. Flow Curves The information presented in this material is based on technical data and test...
Open the catalog to page 103 Pages
4 Pages
12 Pages
2 Pages
12 Pages
3 Pages
24 Pages
20 Pages
8 Pages
12 Pages
3 Pages
3 Pages
3 Pages
4 Pages
6 Pages
11 Pages
4 Pages
20 Pages
2 Pages
6 Pages
20 Pages
12 Pages
24 Pages
12 Pages
2 Pages
3 Pages
2 Pages
3 Pages
2 Pages
2 Pages
3 Pages
3 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
20 Pages
8 Pages
6 Pages
12 Pages
3 Pages