video corpo

Q.bloxx XE A127

Q.bloxx XE A127

Q.bloxx XE A127

Product catalog summary
Overview
The Q.bloxx XE A127 is a high-performance module for measuring electrical power, part of the Q.series product family. It is designed for distributed installations requiring high performance and custom sensor terminations. The module features integrated signal conditioning and arithmetic functions, housed in modular, DIN Rail mountable enclosures.
Key Features
  • EtherCAT DAQ solution with RS-485, 2-wire, EtherCAT (LVDS) communication.
  • Supports FoE and CoE protocols for optimized data throughput.
  • Electromagnetic compatibility according to EN61000-4 and EN55011.
  • Power supply range of 10 to 30 VDC with DIN rail mounting.
  • Four voltage input channels and two current measurement inputs via shunt resistors.
  • Signal conditioning includes linearization, digital filtering, averaging, and more.
  • High accuracy digitalization with 24-bit ADC and 100 kHz sample rate per channel.
  • Galvanic isolation with 1200 VDC isolation voltage.
Technical Specifications
  • Analog Inputs: 4 channels with typical accuracy of 0.01%.
  • Measurement Modes: Voltage and current with specified ranges and errors.
  • Analog/Digital Conversion: 24-bit resolution, 100 kHz update rate, Sigma-Delta modulation.
  • Digital Filters: Configurable IIR filters with various options.
  • Communication Interface: EtherCAT with RS-485 standard.
  • Environmental Conditions: Operating temperature from -20°C to +60°C, storage from -40°C to +85°C.
Safety and Mechanical Information
  • High voltage warnings emphasize the need for trained personnel and proper safety measures.
  • Mechanical specifications include aluminum and ABS materials, dimensions of 30x145x160mm, and a weight of approximately 500g.
Ordering Information
Article number: 567632
See more

Catalog excerpts

Q.bloxx XE A127-1

■ Electromagnetic Compatibility according to EN61000-4 and EN55011 ■ Power supply 10 ... 30 VDC and DIN rail mounting (EN60715) Q.bloxx XE is a new addition to the Q.series product family - the ideal EtherCAT DAQ solution for widely distributed installations that require higher performance and custom sensor terminations. Q.bloxx XE measurement modules possess integrated signal conditioning and arithmetic functions, packaged in modular, DIN Rail mountable enclosures that easily snap together for system expansion and are capable of measuring up to 100 kHz per channel with short cycle times and low jitter for accurate synchronization. ■ RS-485, 2-wire, EtherCAT (LVDS) ■ FoE (file access over EtherCAT, ETG.1000.5) and CoE (CAN over EtherCAT, ETG.50001.1) ■ Configurable PDO mapping to optimize the data throughput Key Features ■ 4 voltage input channels 2 inputs for voltage measurement measuring ranges ±40 V, ±120 V, ±400 V, ±1200 V 2 inputs for current measurement via shunt resistors measuring ranges ±80 mV, ±240 mV, ±800 mV, ±2400 mV ■ Signal conditioning linearization, digital filter, average, scaling, min/max storage, RMS, alarm ■ Fast high accuracy digitalization 24 bit ADC, 100 kHz sample rate per channel Galvanic isolation channel to channel to power supply and to interface isolation voltage 1200 VDC / 848 VACrms test voltage 5 kVDC over 1 minute Categories 1000 V CAT II and 600 V CAT III

 Open the catalog to page 1
Q.bloxx XE A127-2

Gantner instruments Q.bloxx XE A127 Module for Measuring Electrical Power Technical Data Analog Inputs Channels 1 according to EN 61326 2006: appendix B 2 according to EN 61326 2006: appendix A 3 High voltage lifetime (TDDB E Model). Time to fail approx.. 4 years at 1200 VDC and 60 °C continuous Measurement Mode Voltage

 Open the catalog to page 2
Q.bloxx XE A127-3

Gantner instruments Q.bloxx XE A127Module for Measuring Electrical Power Measurement Mode Current

 Open the catalog to page 3
Q.bloxx XE A127-4

Gantner instruments Q.bloxx XE A127 Module for Measuring Electrical Power - Attention High voltage device, Danger for life and health in case of non regular use. - Only special and sufficient educated persons are permitted to handle this device only. - all metal housing parts must be safely and continuous connected to protected earth (PE) - Only contact protection plugs and cables may be used. All parts must be approved for voltages up to 1200 VDC. - During installation, the whole system must be without voltage and safely be disconnected from the mains. - All relevant safety regulations must...

 Open the catalog to page 4
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.