Electromagnetic Compatibility according to EN61000-4 and EN55011 Power supply 10 ... 30 VDC and DIN rail mounting (EN60715) Q.bloxx XE is a new addition to the Q.series product family - the ideal EtherCAT DAQ solution for widely distributed installations that require higher performance and custom sensor terminations. Q.bloxx XE measurement modules possess integrated signal conditioning and arithmetic functions, packaged in modular, DIN Rail mountable enclosures that easily snap together for system expansion and are capable of measuring up to 100 kHz per channel with short cycle times and low jitter for accurate synchronization. ■ RS-485, 2-wire, EtherCAT (LVDS) ■ FoE (file access over EtherCAT, ETG.1000.5) and CoE (CAN over EtherCAT, ETG.50001.1) ■ Configurable PDO mapping to optimize the data throughput Key Features ■ 4 galvanically isolated input channels Voltages at high potential, ranges 100 mV, 1 V, 10 V ■ Signal conditioning 16 virtual channels, linearization, digital filter, average, scaling, min/max storage, RMS, arithmetic, alarm ■ Fast high accuracy digitalization 24 bit ADC, 100 kHz sample rate per channel ■ Galvanic isolation channel to channel to power supply and to interface isolation voltage 1200 VDC / 848 VACrms test voltage 5 kVDC over 1 minute Categories 1000 V CAT II and 600 V CAT III
Open the catalog to page 1Gantner instruments Q.bloxx XE A123 High Isloation Module for Voltages Technical DataAnalog Inputs Channels 1 according to EN 61326 2006: appendix B 2 according to EN 61326 2006: appendix A 3 High voltage lifetime (TDDB E Model): time to fail approx. 4 years at 1200 VDC and 60 °C
Open the catalog to page 2Gantner instruments Q.bloxx XE A123High Isloation Module for Voltages Analog/Digital-Conversion
Open the catalog to page 3Gantner instruments Q.bloxx XE A123 High Isloation Module for Voltages - Attention High voltage device, Danger for life and health in case of non regular use. - Only special and sufficient educated persons are permitted to handle this device only. - all metal housing parts must be safely and continuous connected to protected earth (PE) - Only contact protection plugs and cables may be used. All parts must be approved for voltages up to 1200 VDC. - During installation, the whole system must be without voltage and safely be disconnected from the mains. - All relevant safety regulations must...
Open the catalog to page 4All Gantner Instruments catalogs and technical brochures
-
Q.bloxx EC D105_v28
3 Pages
-
Q.brixx S104_v22_ZH-HANS
2 Pages
-
Q.brixx D107_v27_ZH-HANS
3 Pages
-
Q.bloxx XE A127
4 Pages
-
Q.bloxx XE A124
4 Pages
-
Q.bloxx XE A122
4 Pages
-
Q.bloxx XE A121 LEMO
5 Pages
-
Q.bloxx XE A116
4 Pages
-
Q.bloxx XE A111 BNC
4 Pages
-
Q.bloxx XE A111
4 Pages
-
Q.bloxx XE A109
4 Pages
-
Q.bloxx XE A108-60V
4 Pages
-
Q.bloxx XE A108
4 Pages
-
Q.bloxx XE A106
5 Pages
-
Q.bloxx XE A107
5 Pages
-
Q.bloxx XE A105 CR
4 Pages
-
Q.bloxx XE A105
4 Pages
-
Q.bloxx XE A104 TCK
4 Pages
-
Q.bloxx XE A104
4 Pages
-
Q.bloxx XE A103
4 Pages
-
Q.bloxx XE A102
5 Pages
-
Q.bloxx XL A101
6 Pages
-
Aerospace Engine Testing
4 Pages
-
Q.series EC C101
4 Pages
-
Automotive E-drive Testing
4 Pages
-
Stress and Fatigue Analysis
4 Pages
-
Aerospace Structural Testing
4 Pages
-
High Voltage Battery
4 Pages
-
GI.bench
4 Pages
-
GI.cloud
4 Pages
-
Q.brixx X station B | PN
2 Pages
-
Q.brixx X station T | SSD
2 Pages
-
Q.monixx
4 Pages
-
Q.raxx XE BC
2 Pages
-
XL A101
6 Pages