Q.bloxx XE A104 - 1

Electromagnetic Compatibility according to EN61000-4 and EN55011 Power supply 10 ... 30 VDC and DIN rail mounting (EN60715) Q.bloxx XE is a new addition to the Q.series product family - the ideal EtherCAT DAQ solution for widely distributed installations that require higher performance and custom sensor terminations. Q.bloxx XE measurement modules possess integrated signal conditioning and arithmetic functions, packaged in modular, DIN Rail mountable enclosures that easily snap together for system expansion and are capable of measuring up to 100 kHz per channel with short cycle times and low jitter for accurate synchronization. ■ RS-485, 2-wire, EtherCAT (LVDS) ■ FoE (file access over EtherCAT, ETG.1000.5) and CoE (CAN over EtherCAT, ETG.50001.1) ■ Configurable PDO mapping to optimize the data throughput Key Features ■ 8 analog input channels thermocouple (type B / E / J / K / L / N / R / S / T / U), voltage (±80 mV) ■ High-accuracy digitization 24-bit ADC, 100 Hz sample rate per channel, 50/60 Hz mains rejection ■ Automatic linearization correction optimal position of the interpolation points adjusted to the input range ■ Open thermocouple detection detect broken wire, loose connection or thermocouple burnout ■ 3-Way galvanic isolation 100 VDC channel to channel, 500 VDC channel to power supply and bank ■ Electromagnetic compatibility (EMC) according to IEC 61000-4 and EN 55011

Open the catalog to page 1
Q.bloxx XE A104 - 2

Gantner instruments Q.bloxx XE A104 Thermocouple and Low Voltage Measurement Module Technical DataAnalog Input Channels 1 according to EN 61326 2006: appendix B 2 according to EN 61326 2006: appendix A 3 noise pulses up to 1000 VDC continuous up to 250 VDC

Open the catalog to page 2
Q.bloxx XE A104 - 3

Gantner instruments Q.bloxx XE A104Thermocouple and Low Voltage Measurement Module Thermocouple Measurement

Open the catalog to page 3
Q.bloxx XE A104 - 4

Gantner instruments Q.bloxx XE A104Thermocouple and Low Voltage Measurement ModuleRemarks Validity of all listed specifications are subject to a warm-up period of at least 45 minutes Specifications subject to change without notice office@gantner-instruments.com www.gantner-instruments.com Gantner Instruments Austria | Germany | France | Sweden | India | USA | China | Singapore MontafonerstraGe 4 ■ A-6780 Schruns ■ T +43 55 56 ■ 77 463-0

Open the catalog to page 4

All Gantner Instruments catalogs and technical brochures

  1. GI.bench

    4 Pages

  2. GI.cloud

    4 Pages

  3. Q.monixx

    4 Pages

  4. Q.raxx XE BC

    2 Pages

  5. XL A101

    6 Pages