Group: Gantner Instruments Group
Catalog excerpts
Electromagnetic Compatibility according to EN61000-4 and EN55011 Power supply 10 ... 30 VDC and DIN rail mounting (EN60715) Q.bloxx XE is a new addition to the Q.series product family - the ideal EtherCAT DAQ solution for widely distributed installations that require higher performance and custom sensor terminations. Q.bloxx XE measurement modules possess integrated signal conditioning and arithmetic functions, packaged in modular, DIN Rail mountable enclosures that easily snap together for system expansion and are capable of measuring up to 100 kHz per channel with short cycle times and low jitter for accurate synchronization. ■ RS-485, 2-wire, EtherCAT (LVDS) ■ FoE (file access over EtherCAT, ETG.1000.5) and CoE (CAN over EtherCAT, ETG.50001.1) ■ Configurable PDO mapping to optimize the data throughput Key Features ■ 8 galvanic isolated input channels differential voltage, current via shunt connector Isolation voltage 100 VDC ■ High accuracy digitalization 24 bit ADC, 100 Hz sample rate per channel ■ 2 digital in and 2 outputs input: state, tare, memory reset output: state, alarm, threshhold Signal conditioning linearization, digital filter, average, scaling, min/max storage, arithmetic, alarm ■ Galvanic isolation channel to channel, isolation voltage 100VDC, power supply and interface, isolation voltage 500 VDC
Open the catalog to page 1Gantner instruments Q.bloxx XE A103 Multi-Channel Module for Voltages Technical Data Analog Input
Open the catalog to page 2Gantner instruments Q.bloxx XE A103Multi-Channel Module for Voltages Analog/Digital-Conversion
Open the catalog to page 3Gantner instruments Q.bloxx XE A103Multi-Channel Module for VoltagesOrdering Information Article number office@gantner-instruments.com www.gantner-instruments.com Gantner Instruments Austria | Germany | France | Sweden | India | USA | China | Singapore MontafonerstraBe 4 ■ A-6780 Schruns ■ T +43 55 56 ■ 77 463-0
Open the catalog to page 4All Gantner Instruments catalogs and technical brochures
-
Q.bloxx EC D105_v28
3 Pages
-
Q.brixx S104_v22_ZH-HANS
2 Pages
-
Q.brixx D107_v27_ZH-HANS
3 Pages
-
Q.bloxx XE A127
4 Pages
-
Q.bloxx XE A124
4 Pages
-
Q.bloxx XE A123
4 Pages
-
Q.bloxx XE A122
4 Pages
-
Q.bloxx XE A121 LEMO
5 Pages
-
Q.bloxx XE A116
4 Pages
-
Q.bloxx XE A111 BNC
4 Pages
-
Q.bloxx XE A111
4 Pages
-
Q.bloxx XE A109
4 Pages
-
Q.bloxx XE A108-60V
4 Pages
-
Q.bloxx XE A108
4 Pages
-
Q.bloxx XE A106
5 Pages
-
Q.bloxx XE A107
5 Pages
-
Q.bloxx XE A105 CR
4 Pages
-
Q.bloxx XE A105
4 Pages
-
Q.bloxx XE A104 TCK
4 Pages
-
Q.bloxx XE A104
4 Pages
-
Q.bloxx XE A102
5 Pages
-
Q.bloxx XL A101
6 Pages
-
Aerospace Engine Testing
4 Pages
-
Q.series EC C101
4 Pages
-
Automotive E-drive Testing
4 Pages
-
Stress and Fatigue Analysis
4 Pages
-
Aerospace Structural Testing
4 Pages
-
High Voltage Battery
4 Pages
-
GI.bench
4 Pages
-
GI.cloud
4 Pages
-
Q.brixx X station B | PN
2 Pages
-
Q.brixx X station T | SSD
2 Pages
-
Q.monixx
4 Pages
-
Q.raxx XE BC
2 Pages
-
XL A101
6 Pages