Addressable Devices Self-Test Series Self-Testing Addressable Detectors General The breakthrough Gamewell-FCI® Self-Test Series intelligent plug-in smoke detectors are designed for performance, ease of use and aesthetics. When used with the Gamewell-FCI E4 ElevateTM Series panel and initiated through an app, the Self-Test Series detectors automatically perform maintenance tests of smoke and heat detection without using canned smoke or heat guns. The Self-Test process meets the three core NFPA requirements for detector maintenance: functional test, smoke entry test, and ability to verify a visual inspection has taken place. It is the first detector of its type to be approved by UL. It also retains the great features of the standard 951 series including the enhanced optical sensing chamber which is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. For ease, its sensitivity can also be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel for selective maintenance when chamber contamination reaches an unacceptable level. Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the ASD-PTL3-SELFT. The ATD-L3-SELFT intelligent temperature sensor can be programmed as either a 135°F fixed temperature sensor, a rate of rise and 135°F fixed temperature sensor or a 190°F high temperature sensor through the Fire Alarm Control Panel (FACP). Point ID capability allows each detector’s address to be set with rotary, decimal address switches providing exact detector location. The Gamewell-FCI® Self-Test series detectors are available for our Velociti® applications. Installation Gamewell-FCI® Series plug-in intelligent smoke detectors use a detachable base to simplify installation, service and maintenance. Installation instructions are shipped with each detector. Mount detector base (all base types) on an electrical backbox which is at least 1.5" (3.81 cm) deep. For a chart of compatible junction boxes, see 9021-60540. Note: Because of the inherent supervision provided by the SLC loop, end-of-line resistors are not required. Wiring “T-taps” or branches are permitted for Class “B” wiring only.When using relay or sounder bases, consult the ISO-X/ISO-XA manuals for device limitations between isolator modules and isolator bases. Construction These detectors are constructed of fire-resistant plastic. Gamewell-FCI® Series plug-in intelligent smoke detectors are designed to commercial standards and offer an attractive appearance. Operation Each Gamewell-FCI Self- Test Series detector uses one of the panel’s addresses (total limit is panel dependent) on the Gamewell-FCI Self-Test Signaling Line Circuit (SLC). The detector responds to regular polls from the control panel and reports its type and the status. If it receives a test command from the panel (or a local magnet test), it stimulates its electronics and reports an alarm. It blinks its LEDs when polled and turns the LEDs on when commanded by the panel. The Gamewell-FCI Self- Test Series offers an industry breakthrough with its UL approved Self-Test feature as well as great fire detection performance that represent the latest in smoke detector technology.
Open the catalog to page 1• Introduces small amounts of smoke and heat into the chamber to test both sensors • Automatically tests if the photo sensor smoke entry points are blocked by the dust cover • Verifies that the technician has completed the visual inspection through its built-in beacon and the self test app • Tests detectors across multiple loops and panels concurrently • Listed to UL 268 7th edition and/or UL 521 ARCHITECTURE • Sleek, low-profile, stylish design • Unique single-source design to respond quickly and dependably to a broad range of fires • Integral communications and built-in device-type identification...
Open the catalog to page 2TECHNICAL SPECIFICATIONS The file number(s) below reference the specific listings for the modules in this document. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult factory for latest listing status. ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak Standby current (max. avg.): 200 @ 24 VDC (one communication every 5 seconds with LED enabled) NOTE: If Self Test Smoke Detectors are installed on a SLM-318 loop card (CLP-2PCB), the maximum permissible long line resistance drops to 35 ohms; initial release...
Open the catalog to page 33 Pages
2 Pages
2 Pages
3 Pages
4 Pages
6 Pages