Product catalog summary
Overview: The document provides detailed specifications, options, and reference codes for Galvatherm® flat heaters, specifically type D, manufactured by GALVATEK S.A.S. These heaters are designed for liquid heating applications and comply with safety standards EN 60519-1/2.
Specifications: The heaters feature a cable that heats only the immersed part, insulated with thermal and electric components, and covered with a PFA sheath for chemical resistance. The cable is supported by PVDF, PP, or PFA strips to maintain proper spacing and is mounted on a flexible structure.
Options and Accessories: Options include extra cable lengths, non-heating cables for tank exits, removable guards made of PP or PVDF, and feet for installation at the bottom. Cable-glands and assembly types are available for different immersion heater thicknesses (P30, P40, P90).
Electrical Safety: The heaters are classified under protection class 1 and require earthing. A fault-current protection device (30mA) is recommended for maximum safety.
Reference Numbers: The reference numbers indicate the heater's thickness and power capacity, with codes such as P30, P40, and P90 representing different thicknesses. Power capacities range from 0.5 kW to 15 kW, with single-phase and three-phase voltage options available.
Installation and Dimensions: The document provides a comprehensive table of dimensions and reference numbers for various heater configurations. It also includes guidelines for constructing reference numbers based on support materials, cable details, and assembly codes.
Key Considerations: The heaters are intended solely for liquid heating. For P90 type D heaters, additional dimensions and feet are required. Various voltage options are available, including 110V, 230V, and 460V for both single-phase and three-phase systems.
See more

Catalog excerpts

Galvatherm - Flat immersion heater - Type D-1

Flat heaters type D The Galvatherm heaters are specially designed with a cable that only heats the part that is to be continually immersed. The cable is composed of a heating resistance insulated with thermal and electric components on which is coextruded a PFA sheath insuring a reliable chemical resistance. The cable is rolled up according dimensions & shapes proposed and held with PVDF, PP or PFA strips which ensure the right distance between the rolls. To secure completely the heating part it is then mounted on a flexible structure in PVDF, PP or PFA. Electric safety : the Galvatherm heater complies with protection class 1 of EN 60519-1/2. The cable is screened throughout the entire length by a copper earthing strip. The earthing must be connected to the earth. In order to provide maximum safety, a fault-current (FI) protection device (30mA) should be used.. (small side) (large side) Assembly type convenient for immersion heaters with reference P30 (thickness 30 mm) , P40 (thickness 40 mm) , P90 (thickness 100 mm) On a plastic strip structure PVDF, PP or PFA Options and Accessories Extra length of cables Electrical connecting cable C of type H05 VV-F (PVC) or H07 RN-F (Neopren) Non heating cable N to go out of the tank The Galvatherm heater is only planned to heat liquids. Removable guard Perforated plastic guard PP ou PVDF Ref in PP : PRPPP Ref in PVDF : PRPPF Cable-gland Ø75 mm Standard height 50 mm Other heights possible For installation at the bottom Ref in PP : PIPP Ref in PVDF : PIPF Ref in PTFE : PIPTFE Allow between 200 to 300 mm extra on the H length (H=installation height on N) Ref in PP : PEPP Ref in PVDF : PEPF GALVATEK S.A.S - 9, rue de la Tour du Mesnil-Renard - 78270 Bonnières, France www.galvatek.com - Tél. 01 30 93 07 57 - [email protected]

 Open the catalog to page 1
Galvatherm - Flat immersion heater - Type D-2

The table below informs on the dimensions of the heating part and its references. The reference number begins by P30, P40 or P90. These codes indicate the thickness 's device. P30 = thickness 30 mm / P40 = 40 mm / P90 = 100 mm All dimensions are given with a tolerance of ± 10 mm. Standard cable coating : PFA single layer. Double layer please contact us. GALVATEK S.A.S - 9, rue de la Tour du Mesnil-Renard - 78270 Bonnieres, France www.galvatek.com - Tel. 01 30 93 07 57 - [email protected]

 Open the catalog to page 2
Galvatherm - Flat immersion heater - Type D-3

THREE-PHASES IMMERSION HEATERS KW J x K 230V 3-ph 400V 3-ph KW J x K 230V 3-ph 400V 3-ph 1.5 kW For the construction of the reference, see following page. * If feet option : 6 feet required instead of 4 Other voltage available : GALVATEK S.A.S - 9, rue de la Tour du Mesnil-Renard - 78270 Bonnieres, France www.galvatek.com - Tel. 01 30 93 07 57 - [email protected]

 Open the catalog to page 3
Galvatherm - Flat immersion heater - Type D-4

Construction of the reference number P30 04 05 2 J P 0 0 D 1 code code code exit cable code code N length C length assembly materials code code code code Cable code details Assembly code details Support materials code code frame strips other pieces GALVATEK S.A.S - 9, rue de la Tour du Mesnil-Renard - 78270 Bonnieres, France www.galvatek.com - Tel. 01 30 93 07 57 - [email protected]