Float Switches - MTS
2Pages

{{requestButtons}}

Catalog excerpts

Float Switches - MTS - 1

Float Switches MTS... made of PP, PVDF or Stainless Steel Terminal casing LC Connection cable made between two general tasks: our electronics ETS/ENR offer a simple and economical solution for the controlling and monitoring of liquid levels. Alternatively, a switching voltage up to 25V AC/DC from a control system (for example from a PLC) can be connected directly to the float switches. The function of a float switch is based on the moving float and can be guaranteed only in liquids which do not form encrustation. Dirt in the tank (such as chips, adhesive substances) can also block the movement of the float. In such cases, where a float switch cannot be used, we recommend the use of our level rod-probes, providing the liquid is electrically conductive. Temperature sensor Float switch with one contact, version PG/ plastics Float switch with one contact and integrated temperature sensor, version LC / plastics The float switches are available in various versions: The stepless height adjustment of from the tanks. Float switches in connection with Switching height Contact Float with one switch contact with two switch contacts with three switch contacts with four switch contacts All switch contacts are changeover contacts. As an option, the float switches made of plastic (PP or PVDF) with the terminal casing LC or LC/L with one, two and three switching contacts are also available with integrated temperature sensor (Pt100 in 3-wire-connection). Function A magnet inside the moving float actuates a reed contact mounted in a fixed position within the tube of the float switch. In order to ensure optimal chemical and thermal resistance, the float switches are made of polypropylene (PP), polyvinyliden fluoride the float rod and the easy attachment of the float switch to the container edge is made possible in the plastic version via the holder attached to the float rod. Further mounting options are available on request (e.g. threaded nipples or flanges). The holder of stainless steel level switches is welded and has to be specified with the order. PG version On float switches without a terminal casing and with a permanently connected cable 1.6 m long (other cable lengths to order), the cable enters the tube of the float switch via a cable gland. Degree of protection IP 64 (splash-proof) according to EN 60529. (PVDF) and stainless steel (AISI 316Ti). They are available without a terminal casing (version PG) and directly connected cable (length of 1.6 m) or with the terminal casing LC (material PP) or LC/L (material PVDF). The versions with LC terminal casings permit easy connection of the cables. GALVATEK S.A.S - 9, rue de la Tour du Mesnil-Renard - 78270 Bonnières, France www.galvatek.com - Tél. 01 30 93 07 57 Fax. 01 30 93 25 04 - info@galvatek.fr Monitoring of the level in order to prevent possible damage (dry-running, heating without sufficient liquid) to the devices (pumps, heaters) installed in the tanks or to prevent an overflow of the process liquid Controlling of the level to control procedures automatically (such as dosing of liquids). Float-switch tube Float-switch tube Nominal length Nominal length PG-Sealing screw connection Switching height The measurement of the liquid level is necessary in process containers, storage tanks and galvanising lines, since unwanted variations in these levels (due to evaporation or removal of the liquids) must be corrected. In this respect, a distinction must be

Open the catalog to page 1
Float Switches - MTS - 2

LC version The small terminal casing LC made of PP or LC/L made of PVDF permits cable connection and has the degree of protection IP65 (jet-waterproof) in accordance with EN60529. If the level switch is exposed to high temperatures (liquid temperature >80°C) or in contact with strong oxidizing chemicals (e.g. chrome electrolytes or HNO3) the PVDF terminal casing LC/L should be used. Line connection The terminal block for connecting the cable is accessible with the mounting wrench after unscrewing the cover. Switching points The switching points are set in the factory and cannot be changed....

Open the catalog to page 2

All Galvatek catalogs and technical brochures

  1. Rotkappe BC

    2 Pages

  2. BC and BC/L

    2 Pages

  3. ROTKAPPE ABS

    2 Pages

  4. control box

    2 Pages

  5. Rotkappe LC

    2 Pages