Thermostat technical data - Control range : 0 to 90°C Contact : 1 changeover Switched power : 16A/250V~ Minimum temperature variation : 1K/2min Minimum immersion tube length : 200 mm Maximum immersion tube length : 1500 mm It is also a complete and cost-efficient device combining heating and temperature control. The heater, the temperature sensor and the switching circuit are integrated in one single unit. minimal immersion depth B This heater with built-in regulation has been especially developed for use in tanks when low power is needed in a reduced space. * Nominal length X can also be manufactured differently. Choose PVDF casing whenever temperature is above 80°c or with oxydising chemicals mimi. immersion depth B (mm) Heaters reference Heaters reference Heaters ref.erence materials : all PP materials all PVDF PVDF with PP casing Options and Accessories Extra length of cables Electrical connecting cable C of type H05 VV-F (PVC) Section 3 x 1,5m2 standard length 2 metres Maximum possible X length : 0,5 kW : 1600 mm / 1 kW : 1700 mm 1,5 kW : 1750 mm / 2 kW : 1850 mm 3 kW : 2050 mm Removable guard Perforated plastic guard in PP only HWB support (supplied) Universal wrench to open the terminal casing and get access to temperature settings Dimensions : total height 43 mm total length 130 mm fixing height 15 mm GALVATEK S.A.S - 9, rue de la Tour du Mesnil-Renard - 78270 Bonnières, France www.galvatek.com - Tél. 01 30 93 07 57 - [email protected] Wrench (supplied) The Galvatherm heater is only planned to heat liquid