Catalog excerpts
FPA 4100 SPECIFICATIONS PERFORMANCE Zero drift +/- 2% F.S. with daily autozero Span Drift Sensitivity Linearity Response time: Ambient temperature Dimensions Weight Power & consumption Sample flow 10-36 VDC, 30 watts 90-240 VAC, 50/60 Hz, 30 watts 0.5-1 L/min COMMUNICATIONS Digital Outputs Modbus RS232, Modbus RS485, Modbus TCP/IP optional Digital Inputs Analog Inputs 2 x 4-20 mA, user scalable, loop or self powered Analog Outputs Relays 6 x 4-20 mA, user scalable, loop powered 6 x SPDT relays, 5 amps @ 30 VDC or 8 amps @ 120/240 VAC APPROVALS & CERTIFICATIONS CSA (C, CUS) Class 1 Division 2, Groups BCD CE CSA Class 1, Division 2 field certifications upon request