LTH Series
12Pages

{{requestButtons}}

Catalog excerpts

LTH Series - 1

Compression Sensor Family Manual Sensor Solutions Source Load · Torque · Pressure · Multi-Axis · Calibration · Instruments · Software

Open the catalog to page 1
LTH Series - 2

LTH Compression Sensor Family Manual Table of Contents Key Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Shield Usage and Connections . . . . . . . . . . . . . . . . . . . . . . 9 . . Further Mounting Suggestions. . . . . . . . . . . . . . . . . . . . . . . . 5 Cable Care and Routing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Further Support Resources. . . . . . . . . . . . . . . . . . . . . . . . . . 12 Sensor Solution Source Load · Torque · Pressure · Multi-Axis · Calibration · Instruments · Software

Open the catalog to page 2
LTH Series - 3

LTH Compression Sensor Family Manual Resonant Frequency Large selection of different capacities ranging from 50lbs to 50,000 lbs and inner diameters. Characteristic center through hole to allow items such as bolts to pass through. High Natural frequency resulting fast response time. Robust strain relief Higher IP rating available upon request. High temperature rating, and Vacuum compatible. Compatible in load washer applications. Sensor Solution Source Load · Torque · Pressure · Multi-Axis · Calibration · Instruments · Software

Open the catalog to page 3
LTH Series - 4

LTH Compression Sensor Family Manual Mechanical Installation The following items should be observed to avoid damage to the LTH sensor during installation and usage. • 1. Do not pull on or carry sensor by cable. Avoid conditions that exceed the sensors IP rating. Store in a dry area without fixtures. MAXIMUM MOMENTS AND OFF-AXIS LOADING • Extraneous load information can be used to assist in determining if the sensor can withstand any unavoidable off-axis loads and moments. Extraneous load information can be found at: http://www. futek.com/extraneous-load-factor An extraneous how-to guide can...

Open the catalog to page 4
LTH Series - 5

LTH Compression Sensor Family Manual Mounting and Installation Below is information for proper mounting and installation. Refer to the sensor spec sheet for thread information and proper load cell orientation to maximize performance and limit cable interference. • Measurements are called out on the sensor spec sheet and have the following tolerances based on the number of decimal points present. DECIMAL FORMAT 2. Support on the outer bottom (Fixed End) ring only. 1. Support surfaces must be flat and inline Non-loading surface, do not contact 3. Load must be applied uniformly on entire...

Open the catalog to page 5
LTH Series - 6

LTH Compression Sensor Family Manual Cable Care and Routing • Below is information for proper cable care and handling. Cable material type and length can be found online in the sensor description page. 1. Avoid stress and movement on cable to avoid damage. 2. Properly secure sensor cable to limit cable movement influence. 3. Avoid bending the strain relief. Bends in the cable should not exceed a radius of ten times the diameter of the sensor cable for dynamic, or moving, applications and not exceed a onetime static, permanent, bend of two to three times the diameter of the cable. CABLE...

Open the catalog to page 6
LTH Series - 7

BLACK ALIGN WITH KEY LTH Compression Sensor Family Manual WHITE Electrical Installation BLACK The LTH load cell series utilizes a fourwire bare lead connector as standard and optional models with TEDS capable DB9 connectors. B C Standard four wire connections are +Excitation, –Excitation, +Signal, and –Signal. The standard coloring code for the above listed connections are Red, A D Black, Green, and White. – Excitation (Black) C B DB9 connections offer additional TEDS data and TEDS return connections. LTH EXCITATION POWER LEVELS A Bridge Sensor XXXΩ – Signal (White) Shield (Floating) SENSOR...

Open the catalog to page 7
LTH Series - 8

LTH Compression Sensor Family Manual Sensor DB-9 Assembly MALE DB9 CONNECTOR (SUPPLIED) DB9 Screws Bottom Cover Cover Screws Washer Covers Sensor Solution Source Load · Torque · Pressure · Multi-Axis · Calibration · Instruments · Software

Open the catalog to page 8
LTH Series - 9

LTH Compression Sensor Family Manual Shield Usage and Connections • Cable shielding should be grounded on one end, either the sensor side or instrument side to avoid ground loops. Jacket Shield • A shield connection listed as floating on a sensors spec sheet means the cable shield is not connected on the sensor side and may be connected on the instrument side to ground. Power Supply • A yearly calibration is recommended. But verification and calibration period shall be defined based on application, conditions, endurance and usage. A shunt is an external resistance applied across two points...

Open the catalog to page 9
LTH Series - 10

LTH Compression Sensor Family Manual Troubleshooting When troubleshooting, we recommend that the sensor be removed from any fixtures. In order to confirm that that sensor is operating correctly, we suggest placing the sensor on a firm surface, and to apply a known load. We also recommend using a volt meter with a clean power supply to confirm the sensor is operating correctly. POSSIBLE CAUSE High zero output • Sensor is under preload • Fixtures or bolting stress for causes of pre-load. • Overload shift would not be repairable. • Sensor has been overloaded from too much load, off axis load,...

Open the catalog to page 10
LTH Series - 11

LTH Compression Sensor Family Manual POSSIBLE CAUSE Zero output drift • Unstable power supply, or noisy power supply, to sensor. • Stability of power supply and noise levels. • Internal damage from liquid exposure is not repairable. • Sensor exposed to temperature change. • For temperature changes or unevenly distributed temperature changes. • Recalibration is available for confirmation of sensor performance. • Sensor exposed to pre-load from fixture or mounting. • Possible loose fixtures and bolts • Sensor exposed to liquid or humidity. Creep in output while under load • Load or fixtures...

Open the catalog to page 11
LTH Series - 12

LTH Compression Sensor Family Manual Further Support Resources • Tips on noise reduction can be found at: https:// media.futek.com/content/futek/files/pdf/Manuals_ and_Technical_Documents/how-to-reduceelectrical-noise-in-your-system.PDF • More information about our LTH sensor series can be found online at the FUTEK website. http://www. futek.com/LTH/overview.aspx • A one year recalibration is recommended. But verification and calibration period shall be defined based on application, conditions, endurance and usage. Calibration data may be available online at...

Open the catalog to page 12

All FUTEK Advanced Sensor Technology catalogs and technical brochures

  1. TDF675

    2 Pages

  2. TDF650

    2 Pages

  3. TDF600

    2 Pages

  4. TDF400

    2 Pages

  5. PFT510

    2 Pages

  6. TFF Series

    13 Pages

  7. LLB Series

    13 Pages

  8. LCB Series

    13 Pages

  9. PMP410

    1 Pages

  10. PMP927

    1 Pages

  11. MTA505

    2 Pages

  12. MTA600

    2 Pages

  13. MAU300

    1 Pages

  14. IAC200

    2 Pages

  15. IAA200

    2 Pages

  16. IAA300

    2 Pages

  17. FSH03912

    2 Pages

  18. IHH500 Pro

    4 Pages

  19. FSH03460

    4 Pages

  20. FSH03633

    3 Pages

  21. FSH03395

    2 Pages

  22. FSH03927

    2 Pages

  23. FSH03631

    2 Pages

  24. MODEL IAC200

    2 Pages

Archived catalogs

  1. Automotive

    1 Pages