IHH500 Pro

IHH500 Pro

IHH500 Pro

Product catalog summary
Overview: The IHH500 is a digital handheld display designed for measuring load, torque, pressure, and multi-axis inputs. It supports calibration and offers various output options, including USB and ASCII stream.
Features:
  • Bridge resistance measurement and shunt calibration.
  • User-friendly navigation with keypad options for various functions like track/hold, peak/valley reset, and unit conversion.
  • Supports IEEE1451.4 standard with TEDS templates 30 & 33.
  • Selectable voltage and current output configurations.
  • 16x4 character LCD with adjustable brightness and contrast.
Specifications:
  • Data logging capacity of 21k points and profile storage for 14 profiles.
  • Sampling rate ranges from 5 to 4800 SPS with a bandwidth of sampling rate divided by 4.
  • Internal resolution of 24 bits with nonlinearity of ±0.005% of FSR.
  • IP64 rating for protection against dust and water.
  • Strain gauge mV/V input with a standard range of ±4 mV/V and optional up to ±500 mV/V.
  • Voltage and current input with supply voltage of 24 V.
  • Analog output options include 0–5 or ±5 VDC and various current ranges.
Connectors & Wiring:
  • Power connections are not polarity sensitive.
  • Output connections include analog current and voltage output signals, and solid-state relay outputs.
  • USB port compatible with USB 2.0 only.
  • Sensor connections include excitation, signal, and TEDS data pins.
Sampling Rate & Resolution:
  • Resolution varies with sampling rate, with higher rates resulting in lower resolution.
Accessories:
  • Accessory kit includes all mating connectors and SensIT software.
  • Related accessories include USB cable, analog/relay output cable, and TEDS kit.
Dimensions: The device measures 4.0 x 6.0 x 1.7 inches (101.24 x 153.43 x 43.61 mm).
See more

Catalog excerpts

IHH500 Pro-1

FUTEK ADVANCED SENSOR TECHNOLOGY, INC. FEATURES • Bridge Resistance Measurement • Keypad Options (Track/Hold, Peak/Valley Reset, Unit, Tare/ Gross, Shunt, Battery, Display, Menu) • First Peak/First Valley Feature • User Friendly Navigation Menu • Shunt Calibration • Universal Unit Conversion • Supports IEEE1451.4 Standard (TEDS Templates 30 & 33) • USB Output • ASCII Stream Output • Selectable Voltage and Current Output Configuration LCD • 16 x 4 character LCD with Selectable Height (0.18 [4.75] and 0.49 [12.55]) • 6 Digit Display Plus Sign and Decimal Point or 7 Digit Plus Sign Depending On Application • Auto Power-off • Brightness and Contrast Adjustment IMPORTANT NOTE: ONLY CONNECT DEVICE TO USB 2.0 PORT SPECIFICATIONS GENERAL Data Logging Profile Storage Sampling Rate Bandwidth (Hz) Internal Resolution Resolution (Noise Free) Nonlinearity Integrated Digital Filter Weight Internal Shunt Resistance Value IP Rating STRAIN GAUGE mV/V INPUT Bridge Excitation Standard Input Range Optional Input Range Min. Bridge Resistance VOLTAGE INPUT Supply Voltage Standard Input Range CURRENT INPUT Supply Voltage Standard Input Range OUTPUT Analog Voltage Minimum Load Impedance (Voltage) Analog Current Maximum Load Impedance (Current) Individual Relay Outputs USB ASCII Output Update Rate Precision 5.000 VDC ± 4 mV/V (factory default) Up to ± 500 mV/V 30 Ohm 24 V ±12 VDC; up to 30 mA Sensor Solution Source Load • Torque • Pressure • Multi-Axis • Calibration • Instruments • Software www.futek.com

 Open the catalog to page 1
IHH500 Pro-2

Model IHH500 2CONNECTORS & WIRING POWER CONNECTIONS SENSOR CONNECTIONS PIN SYMBOL PIN SYMBOL DESCRIPTION 1 12V A +E +Excitation Note: These pins are not polarity sensitive. C -E -Excitation, TEDS return USB PORT CONNECTIONS (COMPATIBLE WITH USB 2.0 ONLY) PIN SYMBOL 1 VBUS F 24_OUT 24V outputG GND_OUT Ground/Shield 2 -D J -V -V and -mA Amplified Input 4 GND K +V +V and +mA Amplified Input OUTPUT CONNECTIONS PIN SYMBOL DESCRIPTION 1 IDAC analog current output signal Note: Cable should be connected to pin G, ground, and should be grounded on one end, either...

 Open the catalog to page 2
IHH500 Pro-3

Note: Shield should be connected to cable clamp of binder cable assembly when connecting on instrument side. Sensor cable shield connections should be grounded on one end, either the sensor side or the instrument side, to avoid potential ground loops. SAMPLING RATE SAMPLES PER SECOND (SPS) mV/V RESOLUTION mA AND VDC INPUT RESOLUTION 5 18.2 20.5 Sensor Solution Source Load • Torque • Pressure • Multi-Axis • Calibration • Instruments • Software www.futek.com RoHS & \ KlSOg ■*»

 Open the catalog to page 3
IHH500 Pro-4

OTHER VERSIONS FSH03460 IHH500 - Elite Display w/ Accessory Kit FSH03569 IHH500 Power Supply Adaptor RELATED ACCESSORIES IHH500 ELITE Intelligent Digital Handheld Display, mV/V, VDC, Current and Encoder Measurement, Analog Output, Alarm Relays, TEDS and USB Output — Accessory Kit (FSH03583) With All Mating Connectors and SensIT Software Included ITEM # DESCRIPTION FSH03583 IHH500 - Accessory KitFSH03189 SENSIT Software FSH03720 Bracket and 3x Screws FSH03570 IHH500 USB Cable FSH03572 IHH500 Analog/Relay Output Cable FSH03585 Binder with TEDS Kit Drawing Number: FI1329-L FUTEK...

 Open the catalog to page 4

All FUTEK Advanced Sensor Technology, Inc. catalogs and technical brochures

  1. IHH500

    4  Pages

  2. IPM650

    3  Pages

  3. TDF675

    2  Pages

  4. TDF650

    2  Pages

  5. TDF600

    2  Pages

  6. TDF400

    2  Pages

  7. PFT510

    2  Pages

  8. LTH Series

    12  Pages

  9. TFF Series

    13  Pages

  10. LLB Series

    13  Pages

  11. LCB Series

    13  Pages

  12. PMP410

    1  Page

  13. PMP927

    1  Page

  14. MBA400 series

    2  Pages

  15. MBA500 series

    2  Pages

  16. MTA400 series

    2  Pages

  17. MTA500 series

    2  Pages

  18. MTA505

    2  Pages

  19. MTA600

    2  Pages

  20. MAU300

    1  Page

  21. IAC200

    2  Pages

  22. IAA200

    2  Pages

  23. IAA300

    2  Pages

  24. FSH03912

    2  Pages

  25. FSH03460

    4  Pages

  26. FSH03633

    3  Pages

  27. FSH03395

    2  Pages

  28. FSH03927

    2  Pages

  29. FSH03631

    2  Pages

  30. USB520 series

    3  Pages

  31. MODEL IAC200

    2  Pages

Archived catalogs

  1. Automotive

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.