FSH03633 - 1

MODEL IPM650 Panel Mount Display ADVANCED SENSOR TECHNOLOGY, INC. FEATURES • 21k point data logging • Bridge resistance measurement • Keypad options (Track/Hold - Peak/Valley Reset - Unit - Tare/Gross-Shunt - Channel -Display-Menu) • First peak/first valley feature • User friendly navigation menu • Shunt calibration • Universal unit conversion • 14 Sensor profile storage • Supports 1451.4 standard (TEDS template 30 and 33) • Powers on when plugged in (QSH01633 Version) Data Logging Profile Storage Sampling Rate Internal Resolution Resolution (Noise Free) Nonlinearity Integrated Digital Filter Operating Temperature Storage Temperature Weight Internal Shunt Resistance Value Front Panel IP Rating STRAIN GAUGE mV/V INPUT Bridge Excitation Precision 5.000 VDC Standard Input Range ± 4 mV/V (factory default) Optional Input Range Up to ± 500 mV/V VOLTAGE INPUT Standard Input Range ±12 VDC; up to 30 mA CURRENT INPUT Standard Input Range 0-30 mA IMPORTANT NOTE: ONLY CONNECT DEVICE TO USB 2.0 PORT Minimum Load Impedance (Voltage) 10 kOhm Maximum Load Impedance (Current) 40 Ohm Individual Relay Outputs 2 Digital Packetized Data ASCII Output Update Rate 5 SPS POWER ADAPTER Input Frequency Input Current Output CONFORMITY RoHS CE *Max analog output bandwidth: SPS/4. Refer to IHH500 User Manual for conditions on analog output bandwidth Sensor Solution Source Load • Torque • Pressure • Multi-Axis • Calibration • Instruments • Software www.futek.com RoHS & \ KlSOg ■*»

Open the catalog to page 1
FSH03633 - 2

Model IPM650 2 DIMENSIONS inches [mm] RECOMMENDED PANEL CUTOUT inches [mm] PANEL MOUNT JACK inches [mm] 3 USB Type B Socket Set Screw, #6-32-3/8" Long, Alloy Steel (Zinc-Plated) R0.125 MAX. —/ 0.50 0.50 Maximum recommended wall thickness for panel mount is 3/8" SAMPLING RATE SAMPLES PER SECOND (SPS) 5 50 100 300 1200 2400 4800 Sensor Solution Source Load • Torque • Pressure • Multi-Axis • Calibration • Instruments • Software www.futek.com

Open the catalog to page 2
FSH03633 - 3

Model IPM650 3CONNECTORS & WIRING DIAGRAM AMPLIFIED INPUT A5 -V -V and -mA Amplified Input Connections B5 -E -Excitation C1 -R2 Solid State Relay 2 (-) D1 -VOUT Voltage Output (-) Note: Shield should only be connected on either sensor side or instrument side. If connected on instrument side use following directions. Connect shield to pin A1 or pin A2 of Amplified Input if sensor is amplified. Connect shield to pin B1 of Strain Gauge Input if sensor is strain gauge. Drawing Number: FI1340-M FUTEK reserves the right to modify its design and specifications without...

Open the catalog to page 3

All FUTEK Advanced Sensor Technology catalogs and technical brochures

  1. TDF675

    2 Pages

  2. TDF650

    2 Pages

  3. TDF600

    2 Pages

  4. TDF400

    2 Pages

  5. PFT510

    2 Pages

  6. LTH Series

    12 Pages

  7. TFF Series

    13 Pages

  8. LLB Series

    13 Pages

  9. LCB Series

    13 Pages

  10. PMP410

    1 Pages

  11. PMP927

    1 Pages

  12. MTA505

    2 Pages

  13. MTA600

    2 Pages

  14. MAU300

    1 Pages

  15. IAC200

    2 Pages

  16. IAA200

    2 Pages

  17. IAA300

    2 Pages

  18. FSH03912

    2 Pages

  19. IHH500 Pro

    4 Pages

  20. FSH03460

    4 Pages

  21. FSH03395

    2 Pages

  22. FSH03927

    2 Pages

  23. FSH03631

    2 Pages

  24. MODEL IAC200

    2 Pages

Archived catalogs

  1. Automotive