
FUTEK ADVANCED SENSOR TECHNOLOGY, INC. FEATURES • Speed/Power Measurement • Bridge Resistance Measurement • Keypad Options (Track/Hold, Peak/Valley Reset, Unit, Tare/ Gross, Shunt, Battery, Display, Menu) • First Peak/First Valley Feature • User Friendly Navigation Menu • Shunt Calibration • Universal Unit Conversion • Supports IEEE1451.4 Standard (TEDS Templates 30 & 33) • USB Output • ASCII Stream Output • Selectable Voltage and Current Output Configuration LCD • 16 x 4 character LCD with Selectable Height (0.18 [4.75] and 0.49 [12.55]) • 6 Digit Display Plus Sign and Decimal Point or 7 Digit Plus Sign Depending On Application • Auto Power-off • Brightness and Contrast Adjustment IMPORTANT NOTE: ONLY CONNECT DEVICE TO USB 2.0 PORT Data Logging Profile Storage Sampling Rate Bandwidth (Hz) Internal Resolution Resolution (Noise Free) Nonlinearity Integrated Digital Filter Weight Internal Shunt Resistance Value IP Rating ENCODER INPUT Supply Voltage Encoder Input Speed Measurement Angle Measurement (a) Angle/Speed Measurement (Update Rate) STRAIN GAUGE mV/V INPUT Bridge Excitation Standard Input Range Optional Input Range Min. Bridge Resistance VOLTAGE INPUT Supply Voltage Standard Input Range CURRENT INPUT Supply Voltage Standard Input Range OUTPUT Analog Voltage Minimum Load Impedance (Voltage) Analog Current Maximum Load Impedance (Current) Individual Relay Outputs USB 4.75 VDC Quadrature Leading and Lagging Pulse (TTL) Up to 150k Pulses Per Second Up to 10k Pulses Per Rotation (PPR) 100 ms Precision 5.000 VDC ± 4 mV/V (factory default) Up to ± 500 mV/V 30 Ohm 24 V ±12 VDC; up to 30 mA ASCII Output Update Rate 5 SPS *Max analog output bandwidth: SPS/4. Refer to IHH500 User Manual for conditions on analog output bandwidth Sensor Solution Source Load • Torque • Pressure • Multi-Axis • Calibration • Instruments • Software www.futek.com
Open the catalog to page 1Model IHH500 2 CONNECTORS & WIRING POWER CONNECTIONS PIN SYMBOL 1 12V 2 Ground Note: These pins are not polarity sensitive. USB PORT CONNECTIONS (COMPATIBLE WITH USB 2.0 ONLY) 4 GND OUTPUT CONNECTIONS PIN SYMBOL DESCRIPTION 1 IDAC analog current output signal 2 REFERENCE analog voltage output return 3 +R1 solid state relay 1 (positive) SENSOR CONNECTIONSPIN SYMBOL DESCRIPTION A +E +Excitation C -E -Excitation, TEDS return J -V -V and -mA Amplified Input Connections K +V +V and +mA Amplified Input Connections L PLEAD Leading pulse from sensor...
Open the catalog to page 2# TYPE BINDER ITEM # Note: Shield should be connected to cable clamp of binder cable assembly when connecting on instrument side. Sensor cable shield connections should be grounded on one end, either the sensor side or the instrument side, to avoid potential ground loops. SAMPLING RATE Sensor Solution Source Load • Torque • Pressure • Multi-Axis • Calibration • Instruments • Software www.futek.com RoHS & \ KlSOg ■*»
Open the catalog to page 3Model IHH500 4 DIMENSIONS inches [mm] INCLUDED ACCESSORIESITEM # DESCRIPTIONFSH03569 IHH500 Power Supply AdaptorFSH03189 SENSIT Software FSH03720 Bracket and 3x Screws FSH03570 IHH500 USB Cable FSH03572 IHH500 Analog/Relay Output Cable GOD02975 Binder Male Plug with Cable Clamp Drawing Number: FI1444-B FUTEK reserves the right to modify its design and specifications without notice. Please visit http://www.futek.com/salesterms for complete terms and conditions. Q £ RoHS & -k, & ->j, MANSI K MlSOg
Open the catalog to page 44 Pages
3 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
12 Pages
13 Pages
13 Pages
13 Pages
1 Page
36 Pages
1 Page
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
1 Page
2 Pages
2 Pages
2 Pages
2 Pages
4 Pages
3 Pages
2 Pages
2 Pages
2 Pages
3 Pages
2 Pages
1 Page
36 Pages
68 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
24 Pages
24 Pages
1 Page
1 Page
1 Page