1. Catalogs
  2. Furness Controls
  3. FCO732 - Laminar Flowmeter

FCO732 - Laminar Flowmeter

FCO732 - Laminar Flowmeter

FCO732 - Laminar Flowmeter

Product catalog summary
Overview: The FCO732 is a versatile and cost-effective air/gas flow meter designed for production line testing, calibration of fuel injectors, and various flow measurement applications. It integrates easily with PLCs or PCS and uses Furness Controls' laminar flow technology for accurate measurements.
Key Features:
  • Flow measurement range from 0.01 ml/min to 5000 litres/min.
  • Simultaneous pressure and flow measurement.
  • Programmable cycle times for production testing with up to 50 test settings.
  • Robust steel bench-top case with RS232 or RS485 communication capabilities.
Flow Measurement Specifications:
  • Flow ranges from 0 to 5000 litres/min with accuracy at 20°C: < ± (1% reading + 1 digit) for 10% to 100% range.
  • Resolution: 4-digit display.
  • Temperature coefficients: Zero with automatic zero facility, Span < 0.1% per °C.
  • Long-term drift (span): < 1% per year.
Pressure Measurement Specifications:
  • Pressure ranges from 50 mbar vacuum to 14 bar.
  • Accuracy at 20°C: < ± (1% reading + 1 digit) for 10% to 100% range.
  • Resolution: 4-digit display.
  • Temperature coefficients: Zero < 0.05% per °C, Span < 0.1% per °C.
  • Long-term drift (span): < 1% per year.
Electrical Specifications:
  • Supply voltage: 24 VDC ± 10%, < 500 mA.
  • Control inputs: Up to 12 opto-isolated, active high or low, 5 VDC to 24 VDC.
  • Control outputs: Up to 16 active high transistor output (PNP), 12 VDC to 45 VDC, 120 mA per channel.
Pneumatic Specifications:
  • Media compatibility: Clean dry air or non-corrosive gas.
  • Gas temperature at LFE: 0 – 50°C.
  • Relative humidity of gas: 0 – 95% non-condensing.
  • Air supply pressure: Maximum 10 bar gauge, Minimum 5 bar gauge.
Construction:
  • Enclosure: Steel construction suitable for 19” 3U rack mounting.
  • Dimensions: Rack case - 267 x 133 x 296 mm, Bench case - 232 x 147 x 296 mm.
  • Weight: 5 kg (excluding LFE).
See more

Catalog excerpts

FCO732 - Laminar Flowmeter-1

Flow Meter Flow measurement from 0.01 ml/min to 5000 litres/min Measures pressure and flow simultaneously Programmable cycle times for production testing Up to 50 test settings Robust steel bench-top case Communications via RS232 or RS485 The FCO732 is a cost effective air/gas flow meter suitable for production line testing of gas industry appliances and valves, calibration of fuel injectors and many other flow measuring applications. The FCO732 can be easily interfaced to PLCs or PCS where integration is required. Using the well proven Furness Controls laminar flow technology, the FCO732 adds temperature and barometric pressure compensation to provide an accurate flow measuring system with high resolution. The inherent low flow resistance of the design ensures minimal interference with the flow path. Furness Controls Pressure|Flow|Leak Detection

 Open the catalog to page 1
FCO732 - Laminar Flowmeter-2

Flow ranges Accuracy @ 20°C Resolution Temperature Coefficients Long Term Drift (span) 0 to 20 ml/min 0 to 6 litres/min 0 to 30 litres/min 0 to 200 ml/min 0 to 10 litres/min 0 to 100 litres/min 0 to 2 litres/min 0 to 20 litres/min 0 to 200 litres/min 10% to 100% range: < ± (1% reading + 1 digit) 0 to 10% range: < ± (0.1% range + 1 digit) 4 digit display Zero: Automatic Zero facility , Span: < 0.1% per °C < 1% per year Flow Measurement Pressure Measurement Pressure Ranges Accuracy @ 20°C Resolution Temperature Coefficients Long Term Drift (span) 50 mbar vacuum 300 mbar vacuum 800 mbar vacuum 10%...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.