1. Catalogs
  2. FUJIAN YANAN POWER GROUP
  3. YANAN POWER PLANT CATALOGUE

YANAN POWER PLANT CATALOGUE

YANAN POWER PLANT CATALOGUE

YANAN POWER PLANT CATALOGUE

Product catalog summary

Overview

The document outlines the components and systems involved in a YANANPOWER integrated power generation solution, specifically focusing on a 1250 kW gas generating set configuration. The setup includes two active generating sets and one standby unit.

Main System Components

  • Generating Set: The core power generation units rated at 1250 kW each, with two operational and one reserved for backup.
  • Fuel Supply System: Responsible for delivering fuel to the generating sets, ensuring continuous operation.
  • Lube Oil System: Provides lubrication to the engine components to maintain performance and reduce wear.
  • Exhaust Heat Recovery System: Captures waste heat from exhaust gases to improve overall system efficiency.
  • Cooling System: Maintains optimal operating temperatures for the generating sets and associated equipment.
  • Control System: Manages the operation, monitoring, and safety of the power generation units.
  • Substation: Facilitates power distribution and integration with the broader electrical network.

System Configuration and Operation

The power generation solution is designed with redundancy in mind, featuring two generating sets in active service and one standby unit to ensure reliability and continuous power supply. The integration of auxiliary systems such as fuel supply, lubrication, cooling, and exhaust heat recovery supports efficient and stable operation.

Key Points and Recommendations

  • Maintain regular monitoring and maintenance of the fuel supply and lube oil systems to prevent operational disruptions.
  • Ensure the cooling system is functioning optimally to avoid overheating and potential damage.
  • Utilize the exhaust heat recovery system to enhance energy efficiency and reduce waste.
  • Implement robust control system protocols for safe and efficient management of the generating sets.
  • Keep the standby generating set in ready condition to provide seamless backup power when needed.
See more

Catalog excerpts

YANAN POWER PLANT CATALOGUE-1

YANAN INTEGRATED POWER SOLUTIONS NCCM^CCS IS09001IS014000 IS018000 cWus M <^St?<Ri§lfTft#£!lk

 Open the catalog to page 1
YANAN POWER PLANT CATALOGUE-2

YANAN INTEGRATED POWER SOLUTIONS THE ADVANTAGES OF DISTRIBUTED POWER PLANT Yanan has devoted itself into Industrial self-power station and distributed power generation for many years, We are able to provide a turnkey project support from the global scope and complete power system with one-stop service, including project design, product supply, site operation and technical service in accordance with customer's power demands, site condition and energy supply situation. • m&m&&miim, iffiAmt! ( DPP ) mmzmp • a*sfea ( DPP ) B&amsm. mtmm, m Relative to centralized power supply, the distributed power...

 Open the catalog to page 2
YANAN POWER PLANT CATALOGUE-3

THE GENERAL MODES OF YANNAN INTEGRATED POWER SOLUTIONS THE GENERAL FORMATION AND FEATURES OF MODULAR DESIGN PLAN FORYANAN INTEGRATED POWER STATION • m&mmMm&ms mmmmmMim. n. mmsm. G&mam* ttmmm. mmws&w. • The main generator equipments of distributed power plants usually take the reciprocating internal combustion generating, which has a high thermal efficiency. It can choose diesel, heavy oil and gas generating set according to different fuel. • The rest modular facilities includes intelligent integration control system, low-voltage distribution system, high-voltage distribution system, exhaust heat...

 Open the catalog to page 3
YANAN POWER PLANT CATALOGUE-4

AN ANALYSIS OF ECONOMIC BENEFIT AND EMISSION REDUCTION OF YANAN INTELLIGENT INTEGRATED POWER STATION The economic benefit comparison between CCHP and traditional system (For example, a five-star hotel's commercial power capacity is 3125KVA, the refrigeration capacity in summer is 12000KW) THE CORRELATION TABLE OF FACILITIES AFTER THE FIRST TOTAL INVESTMENT Conclusion: 200 million RMB will be saved after 30 years, just one twenty six of original price difference. Note: Annual average of power load should be 75% of the installed capacity. The price of commercial electricity is RMB0.85/kw.h, the...

 Open the catalog to page 4
YANAN POWER PLANT CATALOGUE-5

YANAN INTEGRATED POWER SOLUTIONS • Emission factor of national grid : 0.8672kg COVkwh • Emission factor of natural gas : 0.0561kg /Mj • Full load CO2 emission of traditional system : CO2 (2500x0.8672 ) + • Full load CO2 emission of BCHP : ( 600+664) x34.7x0.0561=2460 • Full load operation for 365X24X80%=700 one year(estimate) • Be equal to planting 490,000 trees Non-electric lithium bromide genset (also can use afterheat furnace, simply supply hot water or steam] Supplement direct-fired fuel gas Engine (exhaust; cooling water waste heat] Electric energy (cold water; cold air) Heat supply (hot...

 Open the catalog to page 5
YANAN POWER PLANT CATALOGUE-6

• Genset has the functions of such as various operation; automatical and remote monitoring; data acquisition display and security protection. • Inflammable gas such as combustible using natural gas; coal-bed gas; landfill gas; biogas; biological straw gas (Natural gas CH4> 50% .Gas CH4 >30%) • MACH series engine should be ignited by microscale diesel, 240/280 series by spark plug. • All above dimensions are for open type genset, please consult Yanan engineers for the container type genset data. FUJIAN YANAN POWER GROUP Add: No.6 Shugang Road, Zhangwan Industrial District, Dongqiao Economic Development...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.