1. Catalogs
  2. FUJIAN YANAN POWER GROUP
  3. YANAN CUMMINS SERIES GENERATOR SETS

YANAN CUMMINS SERIES GENERATOR SETS

YANAN CUMMINS SERIES GENERATOR SETS

YANAN CUMMINS SERIES GENERATOR SETS

Product catalog summary
Standby Power Specifications:
The document specifies that standby power generators are designed for use during utility power outages. They are not intended for overload conditions or parallel operation with public utilities. These generators are suitable for areas with reliable utility power and should be used for no more than 200 hours annually, with full standby power usage limited to under 25 hours.

Operational Guidelines:
Standby generators should be sized to maintain an 80% average load factor. They are not appropriate for planned power outages coordinated with utility companies.

Alternator Specifications:
The alternator is rated for peak continuous operation at 27°C, in accordance with ISO8528-3 standards.

Dimensions and Weights:
The document details the dimensions and weights for various generator models in both 50Hz and 60Hz configurations. Dimensions are provided in millimeters (LxWxH), and weights in kilograms. Models range from C20/S to C250/S, with dimensions and weights increasing with capacity.

Sound-Proof Generator Sets:
Specifications for sound-proof generator sets are included, with dimensions and weights varying across different models.
See more

Catalog excerpts

YANAN CUMMINS SERIES GENERATOR SETS-1

YANAN POWER GENERATION GENERATING SETS FUJIAN YANAN POWER GROUP

 Open the catalog to page 1
YANAN CUMMINS SERIES GENERATOR SETS-2

GENERATING SETS POWERED BY CUMMINS ENGINE MAIN SPECIFICATION OF GENERATING SETS(50HZ) Open type model C20 GENSET MODEL Soundproof model C20/S Prime output(kw/kva) Standby output (kw/kva) Rating Definitions Prime Power Rating Applicable for supplying electric power in lieu of commercially purchase power. Prime Power applications must be in the form of one of the following. Unlimited Time Running Prime Power Prime Power is available for an unlimited number of hours per year in a varible load application. Variable load should not exceed a 70% average of the Prime. Power rating during anyoperating...

 Open the catalog to page 2
YANAN CUMMINS SERIES GENERATOR SETS-3

GENERATING SETS POWERED BY CUMMINS ENGINE MAIN SPECIFICATION OF GENERATING SETS(50HZ) Open type model C300 GENSET MODEL Soundproof model C300/S Prime output(kw/kva) Standby output (kw/kva) Rating Definitions Standby Power Rating Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility is available. A Standby rated engine should be sized for a maximum...

 Open the catalog to page 3
YANAN CUMMINS SERIES GENERATOR SETS-4

GENERATING SETS POWERED BY CUMMINS ENGINE MAIN SPECIFICATION OF GENERATING SETS(60HZ) GENSET Open type model MODEL Soundproof model Prime output(kw/kva) Standby output (kw/kva) Rating Definitions Prime Power Rating Applicable for supplying electric power in lieu of commercially purchase power. Prime Power applications must be in the form of one of the following. Unlimited Time Running Prime Power Prime Power is available for an unlimited number of hours per year in a varible load application. Variable load should not exceed a 70% average of the Prime. Power rating during anyoperating period of...

 Open the catalog to page 4
YANAN CUMMINS SERIES GENERATOR SETS-5

GENERATING SETS POWERED BY CUMMINS ENGINE MAIN SPECIFICATION OF GENERATING SETS(60HZ) Open type model Soundproof model Prime Output(kw/kva) Standby Output (kw/kva) GENSET MODEL Rating Definitions Standby Power Rating Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. Under no condition is an engine allowed to operate in parallel with the public utility at the Standby Power rating. This rating should be applied where reliable utility is available. A Standby rated engine should be sized for a maximum of an...

 Open the catalog to page 5
YANAN CUMMINS SERIES GENERATOR SETS-6

SOUND-PROOF GENERATOR SETS

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.