Ultrasonic Flowmeters Steam, Liquids, Air For Steam, Liquids, and Air Reliable Flow Measurement

Open the catalog to page 1
Ultrasonic flowmeters for liquids and air - 2

Innovative Solutions for Various Applications Clamp-on Ultrasonic Flowmeter for Steam Fuji Electric’s proprietary “high-sensitivity ultrasonic sensor” and “noise reduction technology” enable clamp-on type saturated steam flow rate measurements. Principle: transit time difference method *1 Applications Flow rate measurement of saturated steam used for heating, drying, sterilization, cleaning, and distillation at factories and offices World’s first clamp-on type saturated steam flow rate measurements Clamp-on Ultrasonic Flowmeter for Liquids • No piping work - cost saving • Installation...

Open the catalog to page 2
Ultrasonic flowmeters for liquids and air - 3

Principle *1: ransit time difference method T A pair of sensors installed on the outside wall of the pipe, facing each other slantingly. The sensors emit ultrasonic pulse in turn, and detect the transit time difference of the pulse, by which the flow rate is calculated. Selection Guide best suitable Flow transmitter Detector TIME DELTA-C TIME DELTA-C advanced type Portable type Transit time Good Principle Bubble resistance Transit time - Applicable fluid Sewage, drainage High-viscosity Oil Corrosive Polishing slurry Fibrous slurry Low-velocity Pulsating Saturated Steam High temperature...

Open the catalog to page 3
Ultrasonic flowmeters for liquids and air - 4

Clamp-on type that achieves saturated steam flow rate measurements Clamp-on Ultrasonic Flowmeter for Steam Flow transmitter: FSJ World’s first clamp-on type saturated steam flow rate measurements Contributes to “visualization” of steam flow and works in combination with EMS to optimize energy and achieve energy savings. ▪ Installable without turning off steam line No piping work required ▪ Effective use of steam energy without pressure loss ▪ Less maintenance costs due to no moving parts Pre-Amp lifier unit Flow transmitter Installable with no pipe cutting or flange processing. Installable...

Open the catalog to page 4
Ultrasonic flowmeters for liquids and air - 5

Enables measurements at low flow rates Noise elimination frame The ultrasonic flowmeter can meusure at low flow rate, even at The heat-resistant rubber frame on the piping surface can re- duce noise and accurate cabtuning of the ultrasonic signals is achieuable. Noise elimination frame Ultrasonic flowmeter Flow rate Other type flowmeter Flow velocity Algorithm dedicated for steam measurement Without noise elimination frame With noise elimination frame Cross section Cross section Transmission sensor Noise Signal C onventional analog processing Noise Signal Measurement failure may occur due...

Open the catalog to page 5
Ultrasonic flowmeters for liquids and air - 6

Clamp-on Ultrasonic Flowmeters for Liquid Applications No Piping Work - Cost Saving ▪ Easy Installation Without Interrupting the Process ▪ Non-Contact and Low Maintenance Sensor Flow Transmitters Hardly Affected by Fluid Pressure and Temperature Superior Bubble Resistance The sensors placed on upstream and downstream emit ultrasonic pulse in turn, and detect the transit time difference of the pulse to calculate the flow rate. Highly accurate measurement can be ob- reduces the interference effect. tained regardless of the type of fluid. Fuji Electric’s advanced anti-bubble measurement...

Open the catalog to page 6
Ultrasonic flowmeters for liquids and air - 7

Clamp-on Detectors for Liquid Applications For pipe diameters from 13 mm to 6000 mm Fluid Mounting Type temperature method [°C] Appearance For small diameter pipes Easy mounting type Pipe inner diameter (mm) and material 13 25 Extended condition (V method) Pipe materials Px : PP, PVDF P : Plastic (PVC, etc.) M : Metallic piping (steel, copper, aluminum, etc.) Mounting method : V method or Z method Detector D Transmitter type Installation of the supplied rail end (Z method) Extendable rail type Use the Z-method when: • You cannot use the V-method due to deficiency of space around the pipe •...

Open the catalog to page 7
Ultrasonic flowmeters for liquids and air - 8

High Accuracy and Wide Measuring Range TIME DELTA-C Flow transmitter: FSV High Accuracy: ±1.0% of Rate For details, refer to the data sheet. Wide Range of Detectors for Pipes 13–6000 mm Including the extendable detector for pipe diameters from 50 mm to 1200 mm Front keys allow you to configure parameters, enter piping conditions, or calculate sensor spacing, without opening the cover. FSSC FSSE Backlit LCD and Front Panel Operation Measurement range 0 … ±0.3 … ±32 m/s Response time Waterproof keypad ±1.0% of rate (depending on flow velocity and diameter) Power supply voltage Green at...

Open the catalog to page 8
Ultrasonic flowmeters for liquids and air - 9

M-Flow PW Flow transmitter: FLR Detector (FSSC) Backlit LCD and Front Panel Operation Detector (FSSA) Analog and Digital Communication Front keys allow you to configure parameters, enter piping conditions, or calculate sensor spacing, without opening the cover. Instantaneous flow rate (8-digit numerals) Equipped with an analog output terminal, two transistor contacts, and an RS-485 communication interface (option). 4Ð20 mA analog output, 1 point, insulated Maximum load resistance: 600Ω Input signals from detector Instantaneous flow velocity (8-digit numerals) Transistor contact, 2 points,...

Open the catalog to page 9
Ultrasonic flowmeters for liquids and air - 10

Portable Type Flow transmitter: FSC Easy Measurement Anytime and Anywhere Handy and battery-driven design allows you to take measurement when and where needed. Consumed Energy Calculation A function to obtain thermal energies exchanged via fluid used in air-conditioning systems. The transmitter calculates the consumed thermal energy based on the forward flow temperature, the return flow temperature, and the flow rate. T1: Forward flow temperature Flow transmitter Using the flow transmitter FSC in combination with the optional pulse doppler detector (FSD) enables real-time monitoring of flow...

Open the catalog to page 10
Ultrasonic flowmeters for liquids and air - 11

Improved Image Quality · Contrast ratio twice as high as the previous model · Holizontal and vertical viewing angles of 80 degrees Easy-to-Mount Detector Mounting detector requires no tools. You can start measurement anytime. · onfigurable display can show info on received waveforms, C logger data, and more · upports various display languages, including English, S Chinese, and German Accessories for Comfortable Operation (option) · Han d strap Helps you hold the transmitter Data Storage on SD Card The transmitter automatically saves the measured data on SD memory card at user-specified...

Open the catalog to page 11

All FUJI ELECTRIC France catalogs and technical brochures

  1. Gas analysers

    21 Pages