Temperature Controller Digital temperature controller PXE is a compact and versatile controller that accepts thermocouples and RTD inputs and controls temperature with the ON-OFF control and PID control. 1. Compact design with a depth of 62 mm including 1.6 mm front panel 4. NEMA 4X front panel 5. Heating and cooling dual control 6. Interface for parameter loader cable (bus-power available) and free loader software SPECIFICATIONS 2. Control function Power supply voltage Control action Input signal 4. Output section of standard type (control output 1) Control output Select one as follows Relay contact: SPST contact: Electrical life 100,000 operations (rated load) Minimum switching current 100mA (24V DC) SSR drive (Voltage pulse): ON: 10.2 to 15 V DC OFF: 0.5V DC or less Max. current: 20mA or less
Open the catalog to page 111. Structure Parameter setting method 6. Alarm or control output 2 (option) Mounting method Alarm kind Table 1 Measuring range table During dual control, the alarm output 1 functions as the control output 2. The alarm is not turned ON immediately even when the process value is in the alarm band. It turns ON when it goes out the alarm band and enters again. Lower limit alarm ■ Lower limit alarm . (with hold) Parameter mask Selectable the Display/Non-display of all function parameters by parameter setting Settable the Display/Non-display of each __parameter block_ | Memory protection | Held by...
Open the catalog to page 2Insulation block diagram Basic insulation (1500 V AC) Power Process value input Internal circuit Control output 1 (relay contact) Alarm output 1 (relay contact) or Control output 2 (relay contact) Alarm output 1 (relay contact) or Control output 2 (relay contact) Alarm output 2 (relay contact) Alarm output 2 (relay contact) When the 9th code is “J”: Each of the alarm output 1 and the alarm output 2 has independent COM terminal. When the 9th code is “1” or “2”: COM terminal is shared between the alarm output 1 and the alarm output 2 SSR drive control output 1 Thermocouple, Resistance bulb Pt100...
Open the catalog to page 3CONNECTION DIAGRAM Alarm output 1 (AL1) or Control output 2 (OUT2)*1 ⑦ Relay contact output Thermocouple input Alarm output 1 (AL1) or Control output 2 (OUT2)*1 Alarm output 1 (AL1) or Control output 2 COM Relay contact output Thermocouple input *1: During dual control, the alarm output 1 functions as the control output 2. Caution on Safety *Before using this product, be sure to read its instruction manual in advance. Instrumentation & Sensors Planning Dept. 1, Fuji-machi, Hino-city, Tokyo 191-8502, Japan http://www.fujielectric.com Phone: +81-42-514-8930 Fax: +81-42-583-8275 http://www.fujielectric.com/products/instruments/...
Open the catalog to page 42 Pages
24 Pages
7 Pages
2 Pages
14 Pages
56 Pages
21 Pages
12 Pages
8 Pages
4 Pages