Overview: The FS4083 is a multi-sensor measuring device designed for monitoring CO2, VOC, temperature, and humidity with an active output of 0-10 V. It features a modern housing design and an optional LCD display.
Specifications: The device measures CO2 (0-2000/5000/10000 ppm), VOC (low/med/high), relative humidity (0-100% RH), and temperature (0...+50°C). It uses a non-dispersive infrared sensor for CO2 and a metal oxide sensor for VOC. The device offers 16 temperature scalings and multiple humidity output options.
Output and Display: The transmitter converts measurements into a 0-10 V analog signal. It can include a backlit LCD display or LED traffic light for CO2 visualization. The device also features a potential-free changeover contact with adjustable switching thresholds.
Calibration and Stability: Automatic calibration for CO2 and VOC occurs every 7 days, ensuring long-term stability. Manual calibration is also possible. The device includes a heating function to protect sensors in high humidity conditions.
Technical Details: The device operates within a temperature range of 0...+50°C and a humidity range of 0-98% RH. It requires a supply voltage of 24 V AC/DC and consumes approximately 100 mA. The housing is made of ABS polyman and is available in signal white.
Installation and Approvals: The FS4083 can be installed on-wall or on a flush-mounted box. It is CE, EAC, and RoHS approved.
Variants: Multiple variants are available, differing in features such as LED traffic lights, relays, and displays.
See more

Catalog excerpts

FS4083-1

DATA SHEET FS4083 Multi-sensor measuring device room for CO2, VOC, temperature and humidity, active output (0-10 V) Measuring size: CO2, VOC, humidity, temperature Output: 0-10 V Highlights: modern housing design, optional LCD-Display Description Depending on the device version, the multi-sensor measuring device records the measured variables CO2 (0-2000/5000/10000 ppm), air quality VOC (low/med/high), relative humidity (0-100% RH) and temperature (0...+50°C). The transmitter converts the measured values into a standardized, analog output signal 0-10 V. As an option, the measuring device has a backlit display or LED traffic light and potential-free changeover contact. The CO2 concentration is visualized via the LED traffic light (green/yellow/red). The version with a backlit LCD display shows the measured values and min/max values of CO2, VOC, relative humidity and temperature. The switching function of the changeover contact can be defined to one of the measured variables using a DIP switch and the switching threshold can be set using a potentiometer. The CO2 concentration is measured using a non-dispersive infrared sensor (NDIR). There are 3 different CO2 scales 0-2000 ppm, 0-5000 ppm, 0-10000 ppm to choose from. The air quality is measured by a VOC sensor and detects the pollution of the ambient air by volatile organic substances such as breathing air, cigarette smoke, body vapours, material emissions, etc. The device has the setting options "low", "medium" or "high" for VOC sensitivity ". The humidity and temperature are measured by a digital sensor, which guarantees a highly accurate and long-term stable measurement result. 16 scalings are available as temperature output. The humidity output signal can be determined from the four measured variables% r.h., g / m³, g / kg and dew point temperature. The measuring device carries out an automatic calibration for CO2 and VOC at regular intervals, which ensures long-term stable measurement. This can be deactivated if necessary or performed manually on the device at any time. In addition, the measuring device has a heating function for sensor protection in the high humidity range of 95 ... 99% r.h. If the relative humidity exceeds the factory-set threshold value for more than 10 minutes, this heating function is activated. The sensor is heated for a limited time, thus dried and protected from condensation. During the heating and subsequent temperature compensation phase, the output signal is kept stable at the last measured value before the protective function was activated. The modern room housing has a quick-release fastener, extra-large ventilation slots, thermal decoupling and much FuehlerSysteme eNET International GmbH - Sales +49 911 37322-190 www.fuehlersysteme.de

 Open the catalog to page 1
FS4083-2

more. The multi-sensor measuring device is ideally suited for use in workplaces, schools, living rooms, medical facilities. FuehlerSysteme eNET International GmbH - Sales +49 911 37322-190 www.fuehlersysteme.de

 Open the catalog to page 2
FS4083-3

Automatic calibration Variants Article Number FuehlerSysteme eNET International GmbH - Sales +49 911 37322-190 www.fuehlersysteme.de

 Open the catalog to page 3
FS4083-4

Article Number FuehlerSysteme eNET International GmbH - Sales +49 911 37322-190 www.fuehlersysteme.de

 Open the catalog to page 4
FS4083-5

Dimensional Drawing FuehlerSysteme eNET International GmbH - Sales +49 911 37322-190 www.fuehlersysteme.de

 Open the catalog to page 5

All FuehlerSysteme eNET International GmbH catalogs and technical brochures

  1. FS4085

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.