SS-1010E
1 /2Pages

SS-1010E

SS-1010E
1 /2Pages

Catalog excerpts

SS-1010E-1

Leading the way in material characterization Selective Sampler SS-1010E Flow Switching System Utilizing Gas Pressure Difference With this device installed, any set of peaks in the Evolved Gas Analysis curve obtained by Multi-Shot Pyrolyzer or Thermogravimetry (TG) can be heart-cut, and solvent peaks and high-boiling species can also be removed. The technique also eliminates flow path contaminations with polar species, and tars on the metal surfaces which are the problems of conventional rotary valve systems, resulting in reduced analysis time and easy maintenance of separation column and detector. Features 1. Heart-Cutting Desired Peaks Any set of peaks in an evolved gas curve can be heart-cut. The components can then be introduced into a capillary column for a specific analysis, allowing significant reduction of time required for analysis. 2. Flow Switching System New flow switching system: an inlet adaptor with a flow path switching system utilizing pressure difference of carrier gas has been employed. The flow path is made of deactivated Ultra ALLOY® capillary tube giving no dead volume or cold spots. Automatic adjustment of purge gas pressure: the system automatically adjusts the purge gas pressure against changes of the separation column length and its inner diameter. Manual or automatic flow switching: the timing of flow path switching can be programmed from Multi-Shot Pyrolyzer temperature controller. Also flow path switching can be manually performed. Various atmosphere gases (He, Air, etc.) can be used: Using air as a sample atmosphere gas gives thermal information under oxidative environment. 3. Simple Construction with Easy Installation The installation is simple and easy. Just attach a selective sampler adaptor to the split / splitless inlet. Flow path Sampling Off Front view of the device (Flow controller) Split vent GC Injection Flow Controller Valve (open) Capillary column

 Open the catalog to page 1
SS-1010E-2

Application 1: Heart-cutting any peak in evolved gas thermogram (This is especially useful when this device and Multi-Shot pyrolyzer or TG are used.) Experiment: A piece of copy paper (3 mm x 3 mm) was heated from 200ºC to 500ºC at 20ºC/min in He carrier gas in the Multi-Shot Pyrolyzer. The evolved gas was directly detected by FID. (A) Before heart-cutting (B) Regions before and after the major components are heart-cut. (C) Major components are heart-cut As shown in this example, any thermal region can be heart-cut. Components that are heart-cut can be analyzed directly by a mass spectrometer...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.