Overview: The document provides technical specifications for the DRIESCHER Single-pole Outdoor Disconnector, Type FTr 3-2000-1B, designed for use in electrical systems.
Specifications:
  • Rated Voltage: 3.6 kV DC
  • Rated Current: 2000 A
  • Rated Isolating Voltage: 4.8 kV DC
  • Rated Short-time Withstand Current: 40 kA
  • Rated Duration of Short-circuit Breaker: 0.25 seconds
  • Rated Impulse Withstand Voltage: 40 kV
  • Power Frequency Test Voltage Level: 18.5 kV
  • Mechanical Life-time: 3000 switching cycles
  • Mounting Position: Horizontal
  • Corrosion Protection: Steel parts are hot-dip galvanized; contact parts are silver-plated according to QTL 0200
  • Creepage Distance: 300 mm
  • Class of Ice Coating: Class 10 (ice coat 10 mm)
  • Recommended Ambient Temperature: -40°C to 50°C
  • Weight: Approximately 20 kg
Standards and Testing: The disconnector is type-tested according to EN 50123-1, EN 50123-3, and EN 50123-4 standards.
Additional Notes: Dimensions, weights, diagrams, and descriptions are non-binding and subject to change without notice. The document emphasizes environmentally friendly practices, such as printing on chlorine-free bleached paper.
See more

Catalog excerpts

Single-pole Outdoor disconnector-1

DRIESCHER Single-pole Outdoor Disconnector FTr 3-2000-1B • Rated voltage Un 3,6 kV DC • Rated current INe 2000 A FTr ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D-85366 MOOSBURG • TEL. +49 87 61 6 81-0 • FAX +49 87 61 68 12 30 http://www.driescher.com [email protected]

 Open the catalog to page 1
Single-pole Outdoor disconnector-2

DRIESCHER - Single-pole Outdoor Disconnectors typetested acc. to EN 50123-1 / EN 50123-3 / EN 50123-4 Single-pole Outdoor Disconnector Type FTr 3-2000-1B Type Nominal voltage Rated voltage Rated isolating voltage Rated current Rated short-time withstand current Rated duration of short-circuit breaker Rated impulse withstand voltage - phase to earth Power frequency test voltage level - phase to earth Mechanical life-time Mounting position Corrosion protection steel parts Corrosion protection contact parts Creepage distance (silicone) Drawing No. Class of ice coating Recommended ambient temperature...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.