1. Catalogs
  2. Fritz Driescher & Söhne GmbH
  3. Outdoor disconnectors, Outdoor earthing switches

Outdoor disconnectors, Outdoor earthing switches
1 /20Pages

Outdoor disconnectors, Outdoor earthing switches

Outdoor disconnectors, Outdoor earthing switches
1 /20Pages

Catalog excerpts

Outdoor disconnectors, Outdoor earthing switches -2

The 1- and 3-pole OutdoorDisconnectors FTr areapplicable for a rated voltage range of 12 kV to 38,5 kV and a rated current range from 630 Ato 4000 A. The rated short time current upto 50 kAfor a duration of 3s depending on the type has been tested. The 3-pole > Installation can be carried out at heights of up to 1000 m above sea level. At heights above 1000 m the rated insulating level of the switch must be cor- rected accordingly. The switches are designed for normal operating conditions according to IEC 62271-1.According to this the following limiting values applies:Ambient temperature: Peak...

 Open the catalog to page 2
Outdoor disconnectors, Outdoor earthing switches -3

12 kV50 Hz31,5 kA3 s80 kA75 kV 28 kV33 kgPD 3E0FT3-1083952-75314400 Type FES 12-20 Rated voltageRated frequency Rated short time current Rated duration of short-time circuit Rated peak withstand current Rated impulse withstand voltage - Phase to Earth Rated power frequency withstand voltage - Phase to Earth Weight approx. Pollution degree of the insulator Electrical life Drawing no. Part no. U > r 12 kV50 Hz20 kA3 s50 kA75 kV 28 kV31 kgPD 3E0FT3-44202/12-75314304 f > r I > k t > k I > p U > p U > d All switches are available with higher pollutiondegree on request! >

 Open the catalog to page 3
Outdoor disconnectors, Outdoor earthing switches -4

Type FES 24-20 FES 24-31,5 FES 24-63 Rated voltageRated frequency Rated short time current Rated duration of short-time circuit Rated peak withstand current Rated impulse withstand voltage - Phase to Earth Rated power frequency withstand voltage - Phase to Earth Weight approx. Pollution degree of the insulator Electrical life Drawing no. Part no. U > r 24 kV50 Hz20 kA3 s50 kA125 kV50 kV37 kgPD 3E0FT3-44202/52-75344305 24 kV50 Hz31,5 kA3 s80 kA125 kV50 kV46 kgPD 3E0FT3-1080502-75344405 24 kV50 Hz63 kA1 s160 kA125 kV50 kV49 kgPD 3E0FT3-44203/52-75344605 f > r I > k t > k I > p U > p U > d All switches...

 Open the catalog to page 4
Outdoor disconnectors, Outdoor earthing switches -5

FTr 12-630-25 FTr 12-1600-40 FTr 12-2500-40 FTr 12-4000-40 Rated voltageRated frequency Rated current Rated short time current Rated duration of short-time circuit Rated peak withstand current Rated impulse withstand voltage - Phase to Earth - Across the Open Gap Rated power frequency withstand voltage - Phase to Earth - Across the Open Gap Weight approx. Mechanical life Pollution degree of the insulator U > r 12 kV50 Hz630 A25 kA3 s63 kA75 kV85 kV28 kV32 kV138 kgM2PD 3 12 kV50 Hz1600 A40 kA3 s100 kA75 kV85 kV28 kV32 kV179 kgM2PD 3 12 kV50 Hz2500 A40 kA3 s100 kA75 kV85 kV28 kV32 kV200 kgM1PD...

 Open the catalog to page 5
Outdoor disconnectors, Outdoor earthing switches -7

Type FTr 24-400-20 FTr 24-630-25 FTr 24-1600-40 FTr 24-2500-40 FTr 24-4000-40 Rated voltageRated frequency Rated current Rated short time current Rated duration of short-time circuit Rated peak withstand current Rated impulse withstand voltage - Phase to Earth - Across the Open Gap Rated power frequency withstand voltage - Phase to Earth - Across the Open Gap Weight approx. Mechanical life Pollution degree of the insulator U > r 24 kV50 Hz400 A20 kA3 s50 kA125 kV145 kV50 kV60 kV138 kgM2PD 3 24 kV50 Hz630 A25 kA3 s63 kA125 kV145 kV50 kV60 kV138 kgM2PD 3 24 kV50 Hz1600 A40 kA3 s100 kA125 kV145...

 Open the catalog to page 7
Outdoor disconnectors, Outdoor earthing switches -10

Type FTr 38,5-400-20 FTr 38,5-630-25 FTr 38,5-1600-31,5 FTr 38,5-2500-40 Rated voltageRated frequency Rated current Rated short time current Rated duration of short-time circuit Rated peak withstand current Rated impulse withstand voltage - Phase to Earth - Across the Open Gap Rated power frequency withstand voltage - Phase to Earth - Across the Open Gap Weight approx. Mechanical life Pollution degree of the insulator U > r 38,5 kV50 Hz400 A20 kA3 s50 kA180 kV210 kV80 kV90 kV128 kgM2PD 3 38,5 kV50 Hz630 A25 kA3 s63 kA180 kV210 kV80 kV90 kV138 kgM2PD 3 38,5 kV50 Hz1600 A31,5 kA3 s80 kA180 kV210...

 Open the catalog to page 10
Outdoor disconnectors, Outdoor earthing switches -14

All switches are available with higher pollution degree on request! > Type FTr 12-630-25-1 FTr 24-630-25-1 FTr 24-1600-40-1 FTr 38,5-630-25-1 Rated voltageRated frequency Rated current Rated short time current Rated duration of short-time circuit Rated peak withstand current Rated impulse withstand voltage - Phase to Earth - Across the Open Gap Rated power frequency withstand voltage - Phase to Earth - Across the Open Gap Weight approx. Mechanical life Pollution degree of the insulator U > r 12/√3 kV50 Hz630 A25 kA3 s63 kA75 kV85 kV28 kV32 kV12 kgM2PD 3 24/√3 kV50 Hz630 A25 kA3 s63 kA125 kV145...

 Open the catalog to page 14
Outdoor disconnectors, Outdoor earthing switches -19

Figure 1. Outdoor disconnector with fuse holders mounted below, with single drive2. Outdoor disconnector with earthing switch mounted below, with double drive Item 1a Single box-type actuator AZ4-7530/1, stroke 110 or 140 mm 1b Double box-type actuator AZ4-7530/2** 2 Single intermediate bearing AZ3-15936/1 2a Double intermediate bearing AZ3-15936/2 3 Single reversible bearing AZ3-17130/1 4 Double reversible bearing AZ3-17130/2 5 Forked clamping crank AZ3-9610/1 (gauge from 73 to 132.5 mm; hole matrix 8.5 mm)6 Single rod head AZ3-9609/7 (with link bush) 7Lower linkage rod, with bearing bush 8...

 Open the catalog to page 19
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.