403 403 DRIESCHER Low voltage fusedswitch-disconnector system 403 • Rated current 400 A up to 1445 A
Open the catalog to page 1protected against accidental contact according to BGV A2, 1-pole and 3-pole switchable Technical data General Fused-switch disconnector system 403, 400 A and 630 A, 1 - and 3 pole switchable Fused-switch disconnector system 403, 400 A and 630 A, with conn. routed up or below Connection types for fused-switch disconnector system 403, 400 A, 630 A and 909 A Feeder circuits for transformers up to 1000 kVA (1445 A) Feeder and coupling circuits 400 A and 630 A Feeder and coupling circuits 1000 A Accessories Earthing and shorting arrangement Mounting of busbars with width more than 40 mm Technical...
Open the catalog to page 2843 DRIESCHER - Low voltage fused-switch disconnector system 403 protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable The requirement of protection against accidental contact as well as switching under load was taken into consideration when developing this system. That means: maximum possible operational and functional saftey! The distribution system is made of high quality plastic press parts and guarantees an ideal circulation of air. 50 ON-OFF operations each were carried out at 550 V/320 V AC and cos φ 0,7 by 500 A, 750 A and 1000 A successfully. By all...
Open the catalog to page 3protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Version 1-pole switchableVersion 3-pole switchable Optionalin OFF-position lockableVersion 3-pole switchable with grip 1) possible connection types, see page 6 2) Cable-covering bonnet, see page 10, on ordering Part-no. Rated Current For lv-fuses Operation b in mm f in mm g in mm s in mm Weig. in kg 4) Use of lv-fuses size 1 in 400 A system and size 2 in 630 A system, possible without changing the connecting element.
Open the catalog to page 4protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable 400 A 1) 2) Cable-covering bonnet, see page 10, on order Optionalin OFF-position lockableVersion 3-pole switchable with grip Part-no. Rated current for lv-fuses Operation 4) Use of lv-Fuses size 1 in 400 A and size 2 in 630 A system, is possible without changing the connecting element.
Open the catalog to page 5protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Version with built in current transformers up to max. 630 A (Connection screws M12 x 55) Version with built in current transformers up to max. 1250 A (Connection screws M12 x 55) Transformer bus for system 403 up to max. 630 A (Connection type acc. to Pos. 1 to 4 @ Transformer bus for system 403 up to max. 1250 A (Connection screws M12 x 55) 1) for example 843 22 113 means distribution system 403 / 400 A, 1-pole switchable
Open the catalog to page 6DRIESCHER - Low voltage fused switch disconnector system 403 protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Incomer circuit for transformers up to 1000 kVA (1445 A) 1) Cable-covering bonnet, see page 10, on ordering Transformer-rating Part-no. lv-fuses Connection Operation Drawing-Nr. Weight in kg
Open the catalog to page 7DRIESCHER - Low voltage fused-switch disconnector system 403 protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Incomer or coupling circuit according to drawing NN3-71303 1) Cover (page 10) and 3 cap nut made of plastic only on ordering. Screw extension from metal nut 8 mm to 15 mm. Connecting bracket (drawing-no. NN4-40947) coupler circuit and busbars only on ordering. Rated current Operation Part-no. Part-no. Rated current k l m Incomer or coupler Connection on theleft Connection on the right outgoing circuit By exchanging the connecting element on the slider...
Open the catalog to page 8protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable according to drawing NN3-71305 Operation Part-no. 1-pole 843 41112 1) Current transformer is not included in the delivery Coupling circuit 1000 Aaccording to drawing NN3-71307 Outgoing Operation Part-no. section l 2) Cover (page 10) and 3 cap nuts made of plastic only on ordering. Screw extension from metal nut 8 mm to 15 mm. Connecting bracket (drawing-no. NN4-40947), between coupling circuit and busbars only on ordering.
Open the catalog to page 9protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Accessories Busbar-covering plate for the distribution system 301 and 403 Made of GFK • 2,5 mm, grey colour with cap nuts made of plastic • for coupling circuit Part-no. 840 30003 Drawing-no. NN4-36540 Drawing-no. NN4-36540 Drawing-no. NN4-36540 Drawing-no. NN4-36540 Work and covering bonnet for distribution system type 403 acc. to DGUV V3 • acc. to drawing NN4-39041 and NN4-41231 Pic. Application Colour Rated current Part-no. Height Width Depth ■0 Covering bonnet for system with normal conn. transparent 400...
Open the catalog to page 10843 DRIESCHER - Low voltage fused-switch disconnector system 403 protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Earthing and shorting arrangements Earthing slider (without earthing set), for conventional earthing accessories with 35 mm2 and 50 mm2 • for rated current 400 A Part-no. 840 31031 Drawing-no. NN4-71309 • for rated current 630 A Part-no. 840 31032 Drawing-no. NN4-71309 Earthing accessories Part-no. 773 11535 Part-no. 773 11550 Earthing accessory Ø Cu 35 mm2 Earthing accessory Ø Cu 50 mm2 Universal earthing case with earthing accessory Ø Cu 35...
Open the catalog to page 11DRIESCHER - Low voltage fused-switch-disconnector system 403 protected against accidental contact according to DGUV V3, 1-pole and 3-pole switchable Mounting of busbars with width more than 40 mm Version 1a and 1b (Picture left) The busbars (≥ 40 mm) are connected to fused switch disconnector system 403 with distance pieces. Part-no. Rated Current Copper-brackets can also be used instead of distance pieces (see Pic. 1b). Version 2 (Picture right) The busbar (≥ 40 mm) is connected to the fused switch disconector system 403 with distance pieces. Due to the extended distance pieces current transformers...