Portier E/A
8Pages

{{requestButtons}}

Catalog excerpts

Portier E/A - 1

Portier Design air curtain for entrances • Recommended installation height 2,5 m* Portier is an exclusive air curtain in brushed stainless steel intended for entrance doors in e.g. shops, banks, hotels and restaurants. The elegant design of the air curtain makes it particularly suitable for environments where demands are made on a high standard of design. • Horizontal mounting • Lengths: 1 and 1,5 m 1 Ambient, no heat 3 Electrical heat: 3-13,5 kW Design Portier has a unique symmetrical design in brushed stainless steel with black grille and ends. Optimized airflow with Thermozone technology. Product specifications • Low sound level. • Adjustable outlet grille makes it possible to direct the air for optimum air curtain effect. • Simple suspension using fixing nuts on the upper side for installation with wall brackets, suspension kit or wire/threaded rod. *) Recommended installation height varies depending on the relevant premises. Measurements according to ISO 27327-1. Average values for products in the series.

Open the catalog to page 1
Portier E/A - 2

Technical specifications ❖Ambient, no heat - Portier A Typ Output Airflow Sound Voltage Amperage Length Weight / Electrical heat - Portier E Typ Output steps Airflow At*2 Sound level Voltage Amperage Length Weight *1) Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent absorption area: 200 m2. *2) At = temperature rise of passing air at maximum heat output and lowest/highest airflow. *3) Alternative 400 V3~ + 230 V~ (operating supply) if the current is greater than 16 A. Applies when connecting several units. Design and specifications are subject to change without...

Open the catalog to page 2
Portier E/A - 3

Portier Mounting and connection Mounting The air curtain is installed horizontally with the supply air grille facing downwards as close to the door as possible. Numerous installation options are available: wall mounting with the wall mounting kit or ceiling mounting with pendulum mounting kit and suspension bracket. The air curtain can be suspended from wires or threaded rods. Minimum distance from outlet to floor for electrically heated units is 1800 mm. For the protection of wider openings, several units can be mounted next to each other using a joining kit. Connection Unit without...

Open the catalog to page 3
Portier E/A - 4

Used for installing unit horizontally on a wall. Consists of wall brackets and mounting parts. Used to join horizontal units together for a sleek and unified installation. Consists of joint bracket and mounting parts. The hanging brackets are covered by a white plastic trim to cover the cables. The brackets may be cut to shorter length, if required. Ceiling brackets for installing the unit from the ceiling using wires or threaded bars (not included). Consists of 4 brackets, 2 for the unit and 2 for the ceiling. Type Description Quantity included

Open the catalog to page 4
Portier E/A - 5

Portier Control options 1 Unit without heating 3 Unit with electrical heating Airflow is set manually. The room thermostat controls the heat output in two steps. Control kit: - CB20, control box, 2 fan steps. Control kit: - CB22, control box, 2 fan steps and 2 heating steps. Level 2 Airflow is set manually. The door contact regulates the airflow on/off. Control kit: - CB20, control box, 2 fan steps. - MDC, magnetic door contact with a time relay. Level 2 Airflow and heat output are controlled automatically based on the opening of the door and the room temperature. When the door is open the...

Open the catalog to page 5
Portier E/A - 6

Controls the airflow in 2 steps. Can control several Controls the airflow in 2 steps and heat output in 2 steps. Can control several units. Max input 10 A. IP44. Processor controlled 2-step thermostat with concealed dial. Setting range +5 - +35 °C. Connection voltage 230 V (two potential free contacts). Max. breaking MDC, magnetic door contact with time relay Starts the air curtain or increases from low to high speed when the door is opened. When the door is closed, the fan continues to run for the preset time (2 s-10 min). This prevents the fan from starting/ stopping continuously and is...

Open the catalog to page 6
Portier E/A - 7

Wiring diagrams Control options for units without heat contact with time Control options for electrically heated units

Open the catalog to page 7
Portier E/A - 8

Portier Wiring diagrams Control options for electrically heated units Level 2 PS210/215E MDC, magnetic door contact with time delay