Catalog excerpts
Equalizes the temperature in buildings with high ceilings Application Ceiling fans are used primarily to equalize the temperature in rooms with high ceilings, such as industrial and warehouse buildings, gymnasiums, and shops. Several controls as well as downrods and blades of different sizes are available, making it possible to adapt ceiling fan ICF to almost all applications. Comfort Warm air is lighter than cold air and therefore rises towards the ceiling. In buildings with high ceilings, a cushion of warm air builds under the ceiling. Ceiling fan ICF pushes down the heated air at a low speed. In this way, the heat is better utilised in the occupied zone without draughts. Ceiling fan ICF can rotate in both ways, an advantage when installed at a low height. Product specifications • The blades push down large volumes of air without causing excessive air speed. • Can operate clockwise and anti-clockwise. • Canopy with vibration absorption. • Fan blades and downrod coated with zinc. • The enclosed motor is equipped with permanently lubricated ball bearings for long life. • Other fan blade diameters are available as an accessory (914, 1218 mm). • Other downrods are available as an accessory (gives a total height of 395, 945 mm). • High protection class, IPX5 (ICF55). • Colour: NCS S 0505-R90B Operation and economy Ceiling fan ICF pushes the warm air from the ceiling and thus lowers the temperature there, the heat losses through the roof and walls are reduced and in many cases, heating costs can be reduced by up to 30%. Ceiling fan ICF is a high quality, maintenance free product with long lifetime, which results in a very short pay-off time, that is often less than one year. Design Industrial ceiling fan ICF has a functional design and white colour which blends well in most premises. The low sound level makes it even more discreet. Reduces heat losses
Open the catalog to page 1Protection class ICF20: (IPX0), normal design. Protection class ICF55: (IPX5), splash-proof design. Approved by IMQ and CE compliant. Ceiling fans Mounting and connection The fans are positioned systematically in the room at equal distances between themselves as detailed in the table below. This is to give the best temperature distribution. To adapt the fan to suit each specific room it should be controlled with a fan speed regualtor. Recommended distance between fans Ceiling height [m] 4 6 8 10 12 Design and specifications are subject to change without notice.
Open the catalog to page 2Control options The fan speed on ceiling fans should be controlled to obtain optimal heat equalization and prevent draughts. The fan can be reversed for summer operation. CAR15 and CFR1R have this function, with other control options a change-over switch is needed. This switch is connected in a series after the control and a 4x1.5 mm2 cable must be used. • CAR15, automatic fan speed control, for maximum15 fans, reversible • CFR1R, 5-step control for 1 fan, reversible • RE1,5 / RE3 / RE5, 5-step control for a maximum of 4, 8 or 12 fans • PE1 / PE2,5 , variable fan speed control for a maximum...
Open the catalog to page 3Wiring diagrams Wiring for fan speed control CAR15, automatic fan speed control PE, variable fan speed control Relay connection Design and specifications are subject to change without notice.
Open the catalog to page 4All FRICO catalogs and technical brochures
-
SWH
11 Pages
-
K21
2 Pages
-
cat_frico_ez100n
6 Pages
-
cat_frico_ar200
12 Pages
-
cat_frico_ags6000
9 Pages
-
cat_frico_ags5000_gb
9 Pages
-
AR3500 A/E/W
9 Pages
-
Corinte ACCS E/W
14 Pages
-
Portier E/A
8 Pages
-
AD200 A/E
14 Pages
-
ADA
2 Pages
Archived catalogs
-
Fan heaters and convectors
162 Pages
-
Air curtain WAC 400
2 Pages
-
Air curtain AD 100
2 Pages
-
Thermoplus
3 Pages
-
Comfort Panel SZ
2 Pages
-
Industrial ceiling fan ICF
4 Pages
-
Capillary tube thermostats
9 Pages
-
Output regulator CIRT
1 Pages
-
Bench heater SH
2 Pages
-
Ribbed pipe radiator
2 Pages