Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)

Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)

Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)

Product catalog summary
Product Overview
The Fresenius Off-Gas System, featuring the Gas Dome 300 and GA320 analyser, is designed for high-performance monitoring of off-gas emissions from wastewater treatment plants (WWTP). It captures and measures nitrous oxide (N2O) and methane (CH4) emissions with high precision, meeting the EU Urban Wastewater Treatment Directive requirements.

System Design and Functionality
The system uses a floating hood with a 1.00 m² footprint to capture off-gas, which flows through a hose to an analyser cabinet without the need for a blower. The analyser measures flow rate and concentration, calculating the emission rate in mg/(m²·h). The system is designed for continuous measurement, with a detection limit of 0.5 ppmV for N2O and a measurement uncertainty of ≤ 2%.

Technical Specifications
The analyser cabinet is weatherproof, heated, and ventilated, suitable for outdoor installation. It supports up to two measuring points, each equipped with a condensate trap and sample gas filter. The system operates with no consumables, using a self-referencing NDIR method that requires no zero or span gas.

Advantages
The system provides a defensible measured emission rate, avoiding estimation errors. It outputs data directly to a PLC or control system, ensuring data privacy without cloud dependencies. The system is cost-effective, with no recurring license costs and minimal additional equipment needed for a second measuring point.

Components and Installation
The system includes a fully assembled and tested analyser cabinet, floating hood, and necessary hoses and fittings. It requires minimal customer-side services, such as electrical supply and control system connection. The system is designed for easy installation and maintenance, with all components available as spare parts.

Performance and Applications
The Off-Gas System is suitable for research-grade measurement campaigns and plants with optimized nitrogen removal. It offers precision measurement capabilities, making it ideal for applications requiring demonstration of small differences in emission rates.
See more

Catalog excerpts

Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-1

PRODUCT OVERVIEW Fresenius Off-Gas-System More Info — Gas Dome 300 + GA320 The expert solution for monitoring off-gas of WWTP

 Open the catalog to page 1
Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-2

HIGH-PERFORMANCE Off-Gas MONITORING Off-Gas SYSTEM EXPERT Maximum measurement performance. Minimum detection limits. For applications in which even very low N2O and CH4 concentrations must be reliably captured and quantified with high precision. Continuous measurement of nitrous oxide and methane emissions from the aeration tanks of wastewater treatment plants measurement uncertainty with humidity and cross-sensitivity compensation For the highest demands on detection limit, accuracy and measurement stability. System schematic A floating hood with a footprint of exactly 1.00 m² captures the rising...

 Open the catalog to page 2
Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-3

Why the Off-Gas System Measured instead of estimated A defined reference area The EU Urban Wastewater Treatment Directive requires accounting for methane and nitrous oxide — transposition by July 2027. A measured emission rate is more defensible than any estimation factor. The hood encloses exactly 1.00 m² and the immersed skirt seals it. No dilution by ambient air — unlike extraction at the tank edge. A key figure that works mg/(m²·h) scales to the whole tank, is comparable between plants and shows immediately whether an operational change really reduces emissions. Self-referencing NDIR with...

 Open the catalog to page 3
Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-4

Technical data The Off-Gas System Expert is the line for precision measurement and low emission values: research-grade measurement campaigns, plants with already optimised nitrogen removal, and every task in which small differences in the emission rate must be demonstrated with confidence. The GA320 achieves a detection limit of 0.5 ppmV for N2O, 0.1 ppmV resolution and ≤ 2 % measurement uncertainty — with humidity compensation, cross-sensitivity compensation and up to six sample gas inlets. Analyser GA320 Measured components and ranges Detection limit Expanded measurement uncertainty Measuring...

 Open the catalog to page 4
Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-5

Completely assembled, wired and factory-tested - ready for connection to power and control system The floating hood Gas Dome 300 - capture at the tank • Collection area exactly 1.00 m2, immersed skirt with chain ballast • Off-gas hose ID 40 mm, 25 m per measuring point • Guy ropes with turnbuckles and boom for strain relief The analyser system Outdoor cabinet with complete periphery • Rain canopy and plinth - weatherproof outdoor installation • Analyser weather-protected inside the cabinet, heated and ventilated • Condensate trap with level monitor and sample gas filter per point • Thermal flow...

 Open the catalog to page 5
Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-6

You receive a completely assembled, wired and tested system — ready for connection to power and control system. All components are industry standard and individually available as spare parts. Gas path per measuring point Condensate trap 300 mm overall height, straight through, with level monitor 1 2 — no drain valve required Sample gas filter In the partial flow directly upstream of the analyser 1 2 Flow measurement with Thermal flow transmitter in the vertically flown metering tube 1 2 DN 50 metering tube widened to DN 50, 0-3 m/s 0-21 m3/h, output 0-10 V or Fresenius Umwelttechnik GmbH - OffGas...

 Open the catalog to page 6
Off-Gas System Expert (Gas Dome 300 + Gas Analyzer)-7

Measuring technology and evaluation Analyser GA320 19” rack unit 3 U in the swing frame, N2O / CH4 / CO2, N2O 1 1 detection limit 0.5 ppmV, measurement uncertainty < 2 %, humidity and cross-sensitivity compensation, 7” touch display Emission rate calculation In the analyser firmware: E = c x q / a in mg/(m2-h), standard 1 1 reference conditions throughout, minimum flow criterion 1 m3/h Assembly and testing Cabinet assembly, wiring, leak and function test at incl. incl. Assembly and testing Off-gas flow rate Complete system 1. One system serves up to two floating hoods; hose length 25 m per line....

 Open the catalog to page 7

All Fresenius Umwelttechnik GmbH catalogs and technical brochures

  1. Substance List

    10  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.