1. Catalogs
  2. Fresenius Umwelttechnik GmbH
  3. Off-Gas System Expert – Brochure

Off-Gas System Expert – Brochure

Off-Gas System Expert – Brochure

Off-Gas System Expert – Brochure

Product catalog summary
Product Overview
The Fresenius Off-Gas System, featuring the Gas Dome 300 and GA320, is designed for high-performance monitoring of off-gas emissions from wastewater treatment plants (WWTP). It captures and analyzes gases like nitrous oxide (N2O) and methane (CH4) with precision, providing emission rates in mg/(m²·h) directly to control systems without the need for blowers or consumables.
System Design and Functionality
The system uses a floating hood with a 1.00 m² footprint to capture off-gas, which flows through a hose to an analyzer cabinet. The system measures both concentration and flow rate to calculate emission rates. It operates without zero or span gas, and data is output directly to the operator's control system, ensuring data privacy.
Technical Specifications
The GA320 analyzer offers a detection limit of 0.5 ppmV for N2O with a measurement uncertainty of ≤ 2%. It features humidity and cross-sensitivity compensation, and can handle up to six sample gas inlets. The outdoor cabinet is weatherproof, heated, and ventilated, ensuring reliable operation in various conditions.
Advantages and Compliance
The system provides measured emission rates, which are more defensible than estimates, aligning with the EU Urban Wastewater Treatment Directive requirements. It offers a scalable and comparable key figure for emissions across different plants. The system is designed for ease of use with no need for calibration gases or cloud subscriptions.
Scope of Supply
The system is delivered fully assembled and tested, ready for connection. It includes the floating hood, GA320 analyzer, and an outdoor cabinet with all necessary components for operation. The system supports up to two measuring points with a single analyzer cabinet.
Comparison with Off-Gas System Smart
The Off-Gas System Expert is designed for precision measurement and low emissions, while the Off-Gas System Smart, featuring the SC300 analyzer, is optimized for routine operational monitoring with a focus on economic efficiency.
See more

Catalog excerpts

Off-Gas System Expert – Brochure-1

PRODUCT OVERVIEW Fresenius Off-Gas-System More Info — Gas Dome 300 + GA320 The expert solution for monitoring off-gas of WWTP

 Open the catalog to page 1
Off-Gas System Expert – Brochure-2

HIGH-PERFORMANCE Off-Gas MONITORING Off-Gas SYSTEM EXPERT Maximum measurement performance. Minimum detection limits. For applications in which even very low N2O and CH4 concentrations must be reliably captured and quantified with high precision. Continuous measurement of nitrous oxide and methane emissions from the aeration tanks of wastewater treatment plants measurement uncertainty with humidity and cross-sensitivity compensation For the highest demands on detection limit, accuracy and measurement stability. System schematic A floating hood with a footprint of exactly 1.00 m² captures the rising...

 Open the catalog to page 2
Off-Gas System Expert – Brochure-3

Why the Off-Gas System Measured instead of estimated A defined reference area The EU Urban Wastewater Treatment Directive requires accounting for methane and nitrous oxide — transposition by July 2027. A measured emission rate is more defensible than any estimation factor. The hood encloses exactly 1.00 m² and the immersed skirt seals it. No dilution by ambient air — unlike extraction at the tank edge. A key figure that works mg/(m²·h) scales to the whole tank, is comparable between plants and shows immediately whether an operational change really reduces emissions. Self-referencing NDIR with...

 Open the catalog to page 3
Off-Gas System Expert – Brochure-4

Technical data The Off-Gas System Expert is the line for precision measurement and low emission values: research-grade measurement campaigns, plants with already optimised nitrogen removal, and every task in which small differences in the emission rate must be demonstrated with confidence. The GA320 achieves a detection limit of 0.5 ppmV for N2O, 0.1 ppmV resolution and ≤ 2 % measurement uncertainty — with humidity compensation, cross-sensitivity compensation and up to six sample gas inlets. Analyser GA320 Measured components and ranges Detection limit Expanded measurement uncertainty Measuring...

 Open the catalog to page 4
Off-Gas System Expert – Brochure-5

Completely assembled, wired and factory-tested - ready for connection to power and control system The floating hood Gas Dome 300 - capture at the tank • Collection area exactly 1.00 m2, immersed skirt with chain ballast • Off-gas hose ID 40 mm, 25 m per measuring point • Guy ropes with turnbuckles and boom for strain relief The analyser system Outdoor cabinet with complete periphery • Rain canopy and plinth - weatherproof outdoor installation • Analyser weather-protected inside the cabinet, heated and ventilated • Condensate trap with level monitor and sample gas filter per point • Thermal flow...

 Open the catalog to page 5
Off-Gas System Expert – Brochure-6

You receive a completely assembled, wired and tested system — ready for connection to power and control system. All components are industry standard and individually available as spare parts. Gas path per measuring point Condensate trap 300 mm overall height, straight through, with level monitor 1 2 — no drain valve required Sample gas filter In the partial flow directly upstream of the analyser 1 2 Flow measurement with Thermal flow transmitter in the vertically flown metering tube 1 2 DN 50 metering tube widened to DN 50, 0-3 m/s 0-21 m3/h, output 0-10 V or Fresenius Umwelttechnik GmbH - OffGas...

 Open the catalog to page 6
Off-Gas System Expert – Brochure-7

Measuring technology and evaluation Analyser GA320 19” rack unit 3 U in the swing frame, N2O / CH4 / CO2, N2O 1 1 detection limit 0.5 ppmV, measurement uncertainty < 2 %, humidity and cross-sensitivity compensation, 7” touch display Emission rate calculation In the analyser firmware: E = c x q / a in mg/(m2-h), standard 1 1 reference conditions throughout, minimum flow criterion 1 m3/h Assembly and testing Cabinet assembly, wiring, leak and function test at incl. incl. Assembly and testing Off-gas flow rate Complete system 1. One system serves up to two floating hoods; hose length 25 m per line....

 Open the catalog to page 7