1. Catalogs
  2. Fresenius Umwelttechnik GmbH
  3. Gas Analyzer GA210 O2 paramagnetic

Gas Analyzer GA210 O2 paramagnetic
1 /3Pages

Gas Analyzer GA210 O2 paramagnetic

Gas Analyzer GA210 O2 paramagnetic
1 /3Pages

Catalog excerpts

Gas Analyzer GA210 O2 paramagnetic-1

The Gas Analyzer 210 02 paramagnetic was developed for quick and easy online measurement of oxygen in process gases. user-friendly operation via touch panel with • High long-term stability and low calibration effort due to reliable paramagnetic measurement method • Continuous measurements with short response time and minimized cross-influences from other gas components • Direct measured value display and menu navigation in plain text • Open interface architecture for flexible data transmission (standard RS232) • Low service costs due to reduced maintenance requirements and high operational reliability • Pharmaceutical industry We are your competent partner for gas measurement applications. Our analyzers are developed and produced exclusively in Germany. Fresenius Umwelttechnik GmbH Doncaster-Platz 5 45699 Herten

 Open the catalog to page 1
Gas Analyzer GA210 O2 paramagnetic-2

Technical Data GAS ANALYZER GA 210 O2 PARAMAGNETIC Model Gas Analyzer 210 O2 paramagnetic Sample Gas Inputs 1 (standard), expandable up to 6 2 calibration inputs (nitrogen, oxygen) Measurement Technology Paramagnetic measuring cell Measurement Uncertainty < 0.5 Vol.-% of the measured value per week Detection limit / Resolution 0.1 Vol.-% Zero point deviation < ±0.1 Vol.-% O2/week (offset) Measured Value Correction None required Pressure Tolerance Standard 0.7 to 1.1 bar (process gas pressure) Internal Sample Gas Pump/ Flow Rate Internal: fixed pre-pressure, constant Yes Standard 4 l/min at sample...

 Open the catalog to page 2
Gas Analyzer GA210 O2 paramagnetic-3

Technische Data GAS ANALYZER GA 210 O2 PARAMAGNETIC Operation Menu navigation via 2.5” resistive touch display Electrical Inputs 4 digital inputs 24 V AC/DC Electrical Outputs 1 digital output “ready” (relay) max 48 V / 500 mA 1 digital output “fault” (relay) max 48 V / 500 mA 4 digital outputs (relay) max 48 V / 500 mA, expandable up to 8 Data Interfaces Standard: RS232 Optional: Profibus DP, Ethernet Modbus TCP, Ethernet IP, Profinet, up to 8 analog outputs (galvanically isolated) 4-20 mA, freely configurable via display menu Operational Readiness Measurement readiness reached after 5 min Full...

 Open the catalog to page 3

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.