1. Catalogs
  2. Fresenius Umwelttechnik GmbH
  3. Gas Analyzer GA150 Data Sheet

Gas Analyzer GA150 Data Sheet

Gas Analyzer GA150 Data Sheet

Gas Analyzer GA150 Data Sheet

Product catalog summary
Overview: The Gas Analyzer GA 150 is designed for quick and easy online measurement of solvent concentrations in the gas phase, particularly where low detection limits are not required. It is suitable for applications such as chemical cleaning, metal degreasing, parts cleaning, monitoring, and inspection.
Areas of Application: The GA 150 offers high long-term stability and low calibration effort due to its patented NDIR measurement method with proven reference pressure measurement. It features direct measured value display and user-friendly operation via a touch panel with plain-text menus.
Advantages: The analyzer has an open interface architecture for flexible data transmission, standard RS232, and low service costs due to reduced maintenance requirements and high operational reliability.
Technical Specifications:
  • Model: Gas Analyzer 150
  • Sample Gas Inputs: 1 (standard), expandable up to 8
  • Sample Gas Outputs: 1
  • Measurement Technology: IR: NDIR dual-pressure reference method, cuvette heated to 50°C
  • Gas Components: Perchloroethene, trichloroethene, dichloromethane, or hydrocarbon solvents
  • Measurement Range: 2 mg/m³ - 40 g/m³
  • Measurement Uncertainty: < 3% of the measured value
  • Detection Limit / Resolution: 2 mg/m³
  • Measurement Interval: 20 s
  • Measured Value Correction: Pressure compensation
  • Pressure Tolerance: Standard 0.7 to 1.1 bar (process gas pressure)
  • Internal Sample Gas Pump/Flow Rate: Standard 4 l/min
  • Internal Gas Routing: Standard PTFE, alternative stainless steel
  • Internal Filter: Stainless steel sintered filter
  • Connections for Sample Gas Line: CK screw connections 6/4, alternative cutting ring fittings 6/4
  • Sample Gas Conditioning: Optional sample gas filter, pressure regulator for inlet pressures up to 100 bar
  • Climatic Conditions: Ambient temperature 5° - 45° C, relative humidity ~ 90%, dew-free
  • Operating Voltage: Standard 230 V AC / 50 Hz, 0.9 A / 207 VA, alternative 115 V AC / 60 Hz or 230 V / 60 Hz
  • Housing: 19” slide-in unit, depth 400 mm
  • Protection Class: IP 20
  • Weight: 13.1 kg
  • Display: Touch display 128 x 64 pixels black/white
  • Operation: Menu navigation via 2.5” resistive touch display
  • Electrical Inputs: 4 digital inputs 24 V AC/DC
  • Electrical Outputs: 1 digital output “ready” (relay) max 48 V / 500 mA, 1 digital output “fault” (relay) max 48 V / 500 mA, 4 digital outputs (relay) max 48 V / 500 mA, expandable up to 8
  • Data Interfaces: Standard RS232, optional Profibus DP, Ethernet Modbus TCP, Ethernet IP, Profinet, up to 8 analog outputs (galvanically isolated) 4-20 mA, freely configurable via display menu
  • Operational Readiness: Measurement readiness reached after 60 s
Contact Information: Fresenius Umwelttechnik GmbH, Doncaster-Platz 5, 45699 Herten, +49 2366/ 93 96 1 – 10, [email protected], www.fresenius-ut.com
Social Media: #greentech Made in Germany, /freseniusumwelttechnik, @fresenius_umwelttechnik, /freseniusumwelttechnik, @fresenius_UT
See more

Catalog excerpts

Gas Analyzer GA150 Data Sheet-1

The Gas Analyzer 150 was developed for quick and easy online measurement of solvent concentrations in the gas phase where low detection limits are not required. • High long-term stability and low calibration effort thanks to patented NDIR measurement method with proven reference pressure measurement • Direct measured value display and user-friendly operation via touch panel with plain-text menus • Open interface architecture for flexible data transmission • Low service costs due to reduced maintenance requirements and high operational reliability • Chemical cleaning • Metal degreasing • Parts cleaning Fresenius Umwelttechnik GmbH Doncaster-Platz 5 45699 Herten % wwv.fresenius-ut.com #greentech Made in Germany

 Open the catalog to page 1
Gas Analyzer GA150 Data Sheet-2

Technical Data GAS ANALYZER GA 150 Model Gas Analyzer 150 Sample Gas Inputs 1 (standard), expandable up to 8 Measurement Technology IR: NDIR dual-pressure reference method, cuvette heated to 50°C Gas Components 1 x NDIR (Perchloroethene, trichloroethene, dichloromethane or hydrocarbon Measurement Uncertainty < 3 % of the measured value Detection limit / Resolution 2 mg/m3 Measured Value Correction Pressure compensation Pressure Tolerance Standard 0.7 to 1.1 bar (process gas pressure) Internal Sample Gas Pump/ Yes Flow Rate Standard 4 l/min Internal Gas Routing Standard PTFE Alternative stainless...

 Open the catalog to page 2

All Fresenius Umwelttechnik GmbH catalogs and technical brochures

  1. Substance List

    10  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.