1. Catalogs
  2. Fresenius Umwelttechnik GmbH
  3. BioBasic Biomethane Data Sheet

BioBasic Biomethane Data Sheet

BioBasic Biomethane Data Sheet

BioBasic Biomethane Data Sheet

Product catalog summary
Overview
The BioBasic Biomethane is an advanced online gas analyzer designed for the continuous monitoring of biomethane quality at treatment and grid injection plants. It measures methane (CH4), carbon dioxide (CO2), oxygen (O2), and hydrogen sulfide (H2S) at one-second intervals, providing rapid feedback to complement traditional process gas chromatographs.

Application
This analyzer is used to monitor the quality of biomethane after biogas processing, ensuring that the gas meets network specifications before being transferred to the gas network. Unlike traditional gas chromatographs that provide readings every few minutes, the BioBasic offers real-time monitoring, allowing for immediate adjustments to maintain gas quality.

Advantages
  • Rapid measurement response time of one second.
  • Utilizes NDIR dual-beam method for CH4 and CO2, ensuring high long-term stability.
  • H2S is measured using NDUV with a reference detector, which is sensitive and wear-free.
  • Features automatic, error-monitored calibration.
  • Plug & Play operation with a touch panel interface.
  • Displays errors and faults in plain text.
  • Offers flexible data transmission options, including 4–20 mA and fieldbus.
  • Available in a pump-free version.

Technical Specifications
  • Measurement Technology: CH4/CO2 via NDIR dual-beam, O2 via electrochemical, H2S via NDUV.
  • Measurement Ranges: CH4 (90–100 vol.%), CO2 (0–10 vol.%), O2 (0–30 vol.%), H2S (0–100 ppm).
  • Resolution: CH4 (0.1 vol.%), CO2 (0.01 vol.%), O2 (0.05 vol.%), H2S (0.1 ppm).
  • Measurement Interval: Continuous, every second.
  • Temperature Compensation: NDIR and NDUV cells stabilized at 45°C.
  • Gas Transport: Internal sample gas pump at 4l/min, with an optional pump-free version.
  • Calibration: Automatic with test and zero gas, adjustable intervals.
  • Operating Conditions: Ambient temperature 20–30°C, relative humidity ~90%, air-conditioned indoor installation.
  • Power Supply: Standard 230 V AC / 50 Hz, with alternatives available.
  • Protection Class: IP 54.
  • Weight: 18 kg.
  • Display: 128 × 64 pixels touchscreen.
  • Data Interfaces: Standard 4–20 mA output, with optional Profibus DP, Profinet, Ethernet IP, Modbus TCP.
  • Safety: ATEX-certified flame arrester, UL/CSA listed.

Contact Information
Fresenius Umwelttechnik GmbH, Doncaster-Platz 5, 45699 Herten, Germany. Phone: +49 2366/ 93 96 1 – 10, Email: [email protected], Website: www.fresenius-ut.com
See more

Catalog excerpts

BioBasic Biomethane Data Sheet-1

CH4 | CO2 | O2 | H2S The BioBasic Biomethane is a combined online gas analyser for the rapid, continuous monitoring of biomethane quality at treatment and grid injection plants. It measures CH4, CO2, O2 and H2S at one-second intervals — serving as a rapid, process-close complement to the process gas chromatograph. APPLICATION The BioBasic Biomethane monitors the quality of the product gas following biogas processing — directly at the point of transfer to the gas network. Whilst the custody-transfer process gas chromatograph only provides a reading every few minutes, the BioBasic takes measurements every second and immediately highlights any fluctuations in quality — this allows the processing system to be quickly readjusted and ensures that the gas fed into the network remains within the network specifications. • Measurement in a matter of seconds (1 s) — rapid process response • NDIR dual-beam method (CH4/ CO2), high long-term stability • H2S measurement using NDUV with a reference detector — sensitive, wear-free • Automatic, error-monitored calibration • Plug & Play, operated via touch panel • Errors/faults displayed in plain text • Flexible data transmission (4–20 mA / fieldbus) • Optional pump-free version • Biomethane feed-in systems • Gas network transfer stations • Biogas upgrading • Power-to-Gas / SNG Fresenius Umwelttechnik GmbH Doncaster-Platz 5 [email protected] www.fresenius-ut.com

 Open the catalog to page 1
BioBasic Biomethane Data Sheet-2

Technical Data GAS ANALYZER BioBasiC Biomethane Model BioBasic Biomethane Measurement technology CH4 / CO2: NDIR dual-beam method H2S: NDUV with reference detector Precision CH4: 0.1% of the full-scale value of the measuring range CO2: 0.05% of the full-scale value of the measuring range O2: 0.1% of the full-scale value of the measuring range H2S: 0.2% of the full-scale value of the measuring range Expanded measurement uncertainty CH4: 0.2% of the full-scale value of the measuring range CO2: 0.5% of the full-scale value of the measuring range O2: 0.3% of the full-scale value of the measuring...

 Open the catalog to page 2
BioBasic Biomethane Data Sheet-3

Technical Data GAS ANALYZER BioBasiC Biomethane Measurement gas outputs 1* measurement gas outlet, ix bypass (bypass not applicable on the pump less version) Connections for the sample gas line CK screw connections 8/6 Internal gas flow PTFE Calibration Automatic (test gas and zero gas), adjustable time interval; duration approx. 4 mins per calibration cycle (no readings available during this time) error monitoring (limits for calibration factor, standard deviation at zero point, offset) Climatic conditions Ambient temperature 20 - 30 °C, relative humidity ~ 90 %, condensation- free, air-conditioned...

 Open the catalog to page 3

All Fresenius Umwelttechnik GmbH catalogs and technical brochures

  1. Substance List

    10  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry