1. Catalogs
  2. FRER
  3. Analog meters
video corpo

Analog meters

Analog meters
1 / 83 PagesView full catalog

Analog meters

Product catalog summary
Ordering Codes and Dimensions
Various instruments such as power-factor meters, watt/var meters, DC ammeters, and voltmeters are detailed with their respective ordering codes and dimensions. The dimensions are specified for different models, including 48x48mm, 72x72mm, 96x96mm, and 144x144mm, with corresponding weights.
Technical Data
Each instrument type has specific technical data, including rated burden and overload capacities, accuracy of 1.5%, operating temperature range from -25°C to +50°C, and storage temperature from -40°C to +80°C. Protection ratings for housing (IP52) and terminals (IP00) are provided, with compliance to CEI-DIN-VDE-IEC standards.
Instrument Types
  • Power-Factor Meters: Available for single-phase and three-phase systems with various input voltage and current options.
  • Watt/Var Meters: Available for single-phase and three-phase systems, with accessory transducers and customizable scales.
  • DC Ammeters: Available for direct input and input from shunts, with a wide range of current inputs and scales.
  • DC Voltmeters: Available for direct input and input from voltage dividers, with various voltage ranges.
  • Process Signal Indicators: Accept inputs from transducers with customizable scales.
  • Tachometers: Available with full-scale adjustment and inputs from alternators or dynamos.
Technical Specifications
  • Operating Frequency: 45-65Hz
  • Continuous Overload: 1.2 Vn
  • Instantaneous Overload: 2 Vn
  • Accuracy: 1.5%
  • Overvoltage Category: CAT III 600V P.D. 2
  • Operating Temperature: -25 to +50 °C
  • Storage Temperature: -40 to +80 °C
  • Connections: M4
  • Protection for Housing: IP52
  • Protection for Terminals: IP00
  • Manufactured According to: CEI-DIN-VDE-IEC standards
Product Options
  • Backside Panel Mounting Frame: Available in various sizes (e.g., CP71, CP91)
  • Black Frame: Pressure mountable option available
Ordering Codes and Dimensions
  • Voltmeters: Available in dimensions 70x60mm and 90x80mm with various voltage ranges (e.g., 40V to 600V)
  • Ammeters: Direct input and shunt input options available with ranges from 1mA to 15kA
  • Synchronizing Sets: Dimensions 96x96mm and 144x144mm with primary VT ranges from 220V to 1000V
Wiring Diagrams
Detailed wiring diagrams are provided for different configurations and product types.
Notes
For values different from those indicated in the tables, contact FRER for feasibility verification.
Technical Specifications
  • General Specifications: Operating Temperature: -25 to +50 °C, Storage Temperature: -40 to +80 °C, Housing Protection: IP52, Terminal Protection: IP00, Overvoltage Category: CAT III 600V P.D. 2, Manufactured according to CEI-DIN-VDE-IEC standards
  • Double Frequencymeters: Dimensions: 96x96mm or 144x144mm, Scale Options: 45-55 Hz, 45-65 Hz, 55-65 Hz, 360-440 Hz, Rated Burden: 1W, 2 VA @500V, Input Range: 57.7 to 440V ±15%, Accuracy: 0.5%, Temperature Stability: ±50ppm/°C
  • Differential Voltmeters: Dimensions: 96x96mm or 144x144mm, Scale: ± 20 ΔVn% (standard), ± 10 ΔVn%, Input Options: 100V, 230V, 400V, 440V, Rated Burden: 8VA, Input Range: 90 to 110% Vn, Accuracy: 1.5%
  • Differential Frequencymeters: Dimensions: 96x96mm or 144x144mm, Scale: ± 20 ΔHzn% (standard), ± 10 ΔHzn%, Input Options: 100V, 230V, 400V, 440V, Frequency Options: 50 Hz, 60 Hz, 400 Hz, Phase Delay Accuracy: 0.1 rad, Frequency Shift Accuracy: ±0.001Hz
  • LED Synchroscopes: Dimensions: 96x96mm or 144x144mm, Frequency Options: 50 Hz, 60 Hz, Voltage Options: 100V, 230V, 400V, 440V, Features: LED indication for phase and frequency matching, checking contact for parallel conditions
  • Lamp Synchroscopes: Dimensions: 96x96mm or 144x144mm, Operating Frequency: 50 to 60Hz, Rated Burden: 1 VA, Accuracy: 1.5%
  • Null Voltmeters: Specific details not provided in the document.
Key Features and Recommendations
  • Ensure all parameters are within specified limits for optimal performance.
  • Use appropriate wiring diagrams for installation.
  • Regularly check and maintain equipment to adhere to safety and performance standards.
Specifications
The document outlines various electrical instruments and their specifications, including voltmeters, frequency meters, synchroscopes, and insulation meters. Key specifications include dimensions (e.g., 96x96mm, 144x144mm), voltage ranges (e.g., 100V, 230V, 400V), and protection ratings (e.g., IP52 for housing, IP00 for terminals). Operating temperatures range from -10°C to +50°C, with storage temperatures from -30°C to +70°C. The instruments are manufactured according to CEI-DIN-VDE-IEC standards.
Procedures
The document provides wiring diagrams for the installation of the instruments. It advises contacting the manufacturer, FRER, for feasibility checks if different values are required than those listed.
Ordering Codes
Detailed ordering codes are provided for each type of instrument, specifying dimensions, type (e.g., flush mounting, pivoted housing), and other features like scale and orientation.
Technical Data
The technical data section includes information on operating frequency (45-65 Hz), overload capacities (continuous overload at 1.2 Un, instantaneous overload at 2 Un), and measurement accuracy (1.5%). It also details alarm settings, relay contact ratings, and set-point indications.
Special Executions and Options
The document lists special execution options such as vibration-proof versions, tropicalization, and ship mounting. It also includes options for different protection levels (e.g., IP54, IP65) and calibration classes.
Accessories
Accessories available include protection terminal covers, rubber gaskets, and sealable front covers for enhanced protection.
Product Overview
This document provides specifications for various rubber terminal covers, panel cutout covers, sealable front doors, and protection rubber gaskets. These components are designed for electrical installations, offering protection and compatibility with different panel sizes.
Specifications
  • Rubber Terminal Covers: Large size suitable for inputs ranging from 20 to 100A.
  • Panel Cutout Covers: Available in sizes 48x48, 72x72, 96x96, and 144x144.
  • Sealable Front Doors: Provide IP65 protection, available in sizes 72x72, 96x96, and 96x48.
  • Protection Rubber Gaskets: Available for panel sizes 48x48, 72x72, 96x96, 144x144, and 96x48.
Dimensions
  • Panel Cutout Covers:
    • 48x48: A=48, B=44, C=45
    • 72x72: A=72, B=67, C=68
    • 96x96: A=96, B=91, C=92
    • 144x144: A=144, B=137, C=138
  • Sealable Front Doors:
    • 72x72: A=88, B=80, C=140
    • 96x96: A=112, B=103, C=180
    • 96x48: A=112, B=56, C=180
  • Rubber Terminal Covers:
    • Code 9SAMPP: A=13, B=36, C=6.5, D=11
    • Code 9SAMP: A=26, B=38, C=7.5, D=14
Key Features
  • High protection level with IP65 rating for sealable front doors.
  • Variety of sizes to accommodate different panel dimensions.
  • Durable materials ensuring long-lasting protection and performance.
See more

Catalog excerpts

Analog meters-1

INDICATOR! ANALOGIC! Analog meters

 Open the catalog to page 1
Analog meters-2

INDICE Index INFORMAZIONI GENERALI General informations INDICATORI MODULARI Modualr meters INDICATORI A PROFILO Profile meters INDICATORI DA PANNELLO Rectangular meters INDICATORI PER SINCRONISMO Sinchronizing Indicators SOVRAPPREZZI PER ESECUZIONI SPECIALI Special executions extraprices ACCESSORI Accessories

 Open the catalog to page 2
Analog meters-3

OINFQRMAZIQNI GENERALI General informations DIMENSIQNI REALI SCALE - Scales lay-out (actualsizes) - Cosfimetro cod. F14... - Power factor meter code F14... 2 - Amperometro o voltmetro per c.a. cod. F96E... scala normale Ammeter or voltmeter for AC code F96E... standard scale zoo 3 - Amperometro ristretto per c.a. cod. F72EA... scala estesa 2In Overload ammeter for AC code F72EA... overload scale 2In 4 - Amperometro ristretto per c.a. cod. F48EA... scala estesa 5In Overload ammeter for AC code F48EA... overload scale 5In 5 - Indicatore scala 0 ^ 100 cod. A14... - Meter scale 0 + 100 code A14......

 Open the catalog to page 3
Analog meters-4

info QUADRANTI CON LETTURA ANTIPARALLASSE - Anti-parallax reading dials Disponibili nei formati: 48x48, 72x72, 96x96, 144x144 solo con scala 240°. Versione standard: quadrante e settore bianchi, divisioni, numeri e indice neri. Versione a richiesta: quadrante e divisioni nere, settore, numeri, simboli e indice gialli o bianchi. Available for sizes: 48x48, 72x72, 96x96, 144x144 with 240° scale only. Standard version: dial and sector white, graduations, numbering. symbols and pointer black On request: dial and gradualtions black, sector, numbering, symbols and pointer yellow or white QUADRANTI...

 Open the catalog to page 4
Analog meters-5

OAMPERQMETRI 90° PER C.A. AD INSERZIONE DIRETTA Direct input 90° AC Ammeters autoconsumo frequenza di funzionamento sovraccarico permanente sovraccarico istantaneo precisione categoria di sovratensione (solo 48x48mm) temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti costruzione a norme DATI TECNICI - Technical data rated burden operating frequency continuous overload instantaneous overload accuracy overvoltage category (48x48mm only) operating temperature storage temperature protection for housing protection for terminals manufactured...

 Open the catalog to page 5
Analog meters-6

OAMPERQMETRI 90° PER C.A. INSERZIONE SU TA CT input 90° AC Ammeters F...EA DATI TECNICI - Technical data autoconsumo frequenza di funzionamento sovraccarico permanente sovraccarico istantaneo precisione categoria di sovratensione (solo 48x48mm) temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti costruzione a norme rated burden operating frequency continuous overload instantaneous overload accuracy overvoltage category (48x48mm only) operating temperature storage temperature protection for housing protection for terminals manufactured...

 Open the catalog to page 6
Analog meters-7

AMPEROMETRITERMICI F...BIM Bimetallic ammeters DATITECNICI - Technical data frequenza di funzionamento operating frequency 45 +65Hz sovraccarico permanente continuous overload 1,2 In UKRMETR TEST STANDARD sovraccarico istantaneo instantaneous overload 10 In precisioneelettromagnetico moving iron accuracy 1,5% precisione termico bimetallic accuracy 3% categoria di sovratensione overvoltage category CAT III 300V, CAT II 600V P.D. 2 tempo di integrazione integration time 15min temperatura di funzionamento operating temperature -25 +50 °C temperatura di magazzinaggio storage temperature -40 +80 °C...

 Open the catalog to page 7
Analog meters-8

DATI TECNICI - Technical data Kz - Kazakhstan UKRMETR TEST STANDARD autoconsumo frequenza di funzionamento sovraccarico permanente sovraccarico istantaneo precisione elettromagnetico precisione termico categoria di sovratensione tempo di integrazione temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti costruzione a norme rated burden operating frequency continuous overload instantaneous overload moving iron accuracy bimetallic accuracy overvoltage category integration time operating temperature storage temperature protection for...

 Open the catalog to page 8
Analog meters-9

OVQLTMETRI 90° PER C.A. AD INSERZIONE DIRETTA Direct input 90° AC Voltmeters DATI TECNICI - Technical data autoconsumo frequenza di funzionamento sovraccarico permanente sovraccarico istantaneo precisione categoria di sovratensione (solo 48x48mm) temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti costruzione a norme rated burden operating frequency continuous overload instantaneous overload accuracy overvoltage category (48x48mm only) operating temperature storage temperature protection for housing protection for terminals manufactured...

 Open the catalog to page 9
Analog meters-10

OVQLTMETRI 90° PER C.A. INSERZIONE SU TV VTinput 90°AC Voltmeters F...EV autoconsumo frequenza di funzionamento sovraccarico permanente sovraccarico istantaneo precisione categoria di sovratensione (solo 48x48mm) temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti costruzione a norme CODICIDIORDINAZIONE - Ordering codes DATI TECNICI - Technical data rated burden operating frequency continuous overload instantaneous overload accuracy overvoltage category (48x48mm only) operating temperature storage temperature protection for housing...

 Open the catalog to page 10
Analog meters-11

F...FP DATI TECNICI - Technical data autoconsumo campo di ingresso precisione stability in temperatura categoria di sovratensione temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti immunita costruzione a norme rated burden input range accuracy temperature stability overvoltage category operating temperature storage temperature protection for housing protection for terminals immunity manufactured according to CODICI DI ORDINAZIONE - Ordering codes DIMENSION! - Dimensions FREQUENZIMETRI - FREQUENCYMETERS Dimension - Dimension: Scala...

 Open the catalog to page 11
Analog meters-12

OCQSFIMETRI 90° 90° Power-Factor Meters F...P DATI TECNICI - Technical data Kz - Kazakhstan EH[ autoconsumo amperometrico autoconsumo voltmetrico campo di ingresso sovraccarico permanente sovraccarico istantaneo precisione alimentazione categoria di sovratensione (solo 48x48mm) temperatura di funzionamento temperatura di magazzinaggio grado di protezione custodia grado di protezione morsetti costruzione a norme rated burden (A) rated burden (V) input range continuous overload instantaneous overload accuracy power supply overvoltage category (48x48mm only) operating temperature storage temperature...

 Open the catalog to page 12

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.