Catalog excerpts
Actual Size TrueTilt™ Single Axis Narrow Range Electrolytic Tilt Sensor Part Number: 0703-0711-99 Operating Specifications Operating range Linear Range Axes of Measurement Linearity (±1°) Symmetry (±1°) Repeatability Resolution Null Offset Cross Axis Roll Sensitivity Long Term Stability/Drift Null Temperature Coefficient (max.) Operating Temperature Storage Temperature Null Impedance (typ.) Time Constant (63.2% of final output) Materials Maximum Current at Null ±3° ±1° 1 ≤3% ≤0.05° ≤5 arc seconds ≤1 arc second ≤0.25° ≤20 arc seconds (±3° roll) ≤5 arc seconds ±1 arc second per °C -20° to +50° C -50° to +100° C 50 kΩ ≤1 second Magnetic metals 0.2 mA (continuous) Dam, building, and bridge construction and monitoring Geophysical tilt metering and monitoring Gyroscopes Laser leveling systems Mining machinery and equipment Zero point and position adjustment View a full list of applications on The Fredericks Company website at www.frederickscom.com. Linear and Operating Range Behavior Physical Characteristics Length Width Height Hole Center Hole Diameter Lead Spacing Lead Diameter Lead Length The 0703-0711-99 TrueTILT™ single axis, narrow range electrolytic tilt sensor has a robust, all metal construction providing durability while maintaining superior tolerances and sensor to sensor performance. It is economical with a high level of linearity and repeatability making it ideal for a versatile range of applications in all sectors. Linear Range Very low power consumption Extremely long life Minimal drift over lifetime compared to MEMS devices Excellent resolution and repeatability Superior performance in extreme temperatures and environments Excellent customer support Manufactured in the United States of America Operating Range RoHS Compliant Direction of Measurement See The Fredericks Company website for a list of term definitions. All test data was acquired with a Fredericks signal conditioner at 23° C. email: sales@frederickscom.com
Open the catalog to page 1TrueTilt™ Single Axis Narrow Angle Electrolytic Tilt Sensor Actual Size Dimensional Drawings When using an excitation circuit not designed by The Fredericks Company, ensure that no direct current is passed through the sensor. Direct current will lead to sensor damage, output drift, and general The 0703-0711-99 and all sensors in the TrueTilt™ series must be mounted horizontally (parallel to the surface of the earth and perpendicular to the force of gravity). For best performance, isolate the sensor from vibrations when mounting it. Further information on sensor fundamentals is provided on...
Open the catalog to page 2All The Fredericks Company catalogs and technical brochures
-
Televac br5003
6 Pages
-
Televac MP7FR Cold Cathode
2 Pages
-
Televac MX4A Convection
2 Pages
Archived catalogs
-
0711-0768-99-0719-1143-99_ds
2 Pages
-
Single Axis Narrow Angle
1 Pages
-
2 A Thermocouple Sensor
2 Pages
-
Glass Mid-Range 0715-4101-99
1 Pages
-
Glass Mid-Range 0714-5701-99
1 Pages
-
Glass Mid-Range 0737-0101-99
1 Pages
-
0703-0703-99 TrueTilt
2 Pages
-
Electrolytictilt
4 Pages