Product catalog summary
Operating Specifications
The TrueTILT™ single axis, mid-range electrolytic tilt sensor operates within a range of ±25° and has a linear range of ±10°. It measures one axis with a linearity of ≤1.0% and repeatability of ≤18 arc seconds. The resolution is ≤1 arc second, with a null offset of ≤1° and roll sensitivity of 0.03% per degree. It maintains long-term stability/drift of ≤0.01° and has a null temperature offset of ≤6 arc seconds per °C. The operating temperature range is -40° to +85° C, and storage temperature is -50° to +100° C. The sensor has a null impedance of 50 K Ohms and a time constant of ≤1 second.

Physical Characteristics
The sensor measures 40.6 mm in length, 7.6 mm in width, and 14.2 mm in height, with a weight of 5.8 g. It features a hole center of 34 mm and a hole diameter of 3.7 mm.

Benefits
Key benefits include very low power consumption, long life, minimal drift compared to MEMS devices, excellent resolution and repeatability, and superior performance in extreme environments. It is manufactured in the USA.

Description
The 0703-1602-99 TrueTILT™ sensor is robust with all-metal construction, suitable for various applications such as construction machinery, railway monitoring, and laser leveling systems.

Applications
The sensor is ideal for use in construction machinery, railway monitoring, laser leveling systems, aerial platform level control, mining, and agricultural machinery.

Certifications and Ratings
The sensor is RoHS compliant.

Notes
It is crucial to avoid passing direct current through the sensor to prevent damage and instability. The sensor should be mounted horizontally and isolated from vibrations for optimal performance.

Related Products
The 6200 series signal conditioners are compatible with the 0703-1602-99 sensor, offering various outputs. The TrueTILT™ series includes sensors with different specifications to meet diverse needs.

Contact Information
The Fredericks Company, 2400 Philmont Avenue, Huntingdon Valley, PA 19006. Tel: 215 947 2500, Fax: 215 947 7464, Email: [email protected], Web: www.frederickscom.com.

Disclaimer
Specifications are subject to change without notice. The Fredericks Company assumes no responsibility for inaccuracies or liabilities arising from product use.
See more

Catalog excerpts

TrueTILT? Mid-Range Single Axis, Linear Output, Electrolytic Tilt Sensor-1

TrueTilt™ Single Axis Mid-Range Electrolytic Tilt Sensor Part Number: 0703-1602-99 Operating Specifications Operating range Linear Range Axes of Measurement Linearity (±10°) Repeatability Resolution Null Offset Roll Sensitivity Long Term Stability/Drift Null Temperature Offset Range Temperature Offset Operating Temperature Storage Temperature Null Impedance Time Constant (63.2% of final output) Materials Maximum Current at Null ±25° ±10° 1 ≤1.0% ≤18 arc seconds ≤1 arc second ≤1° 0.03% per degree ≤0.01° ≤6 arc seconds per °C 0.075% per °C -40° to +85° C -50° to +100° C 50 K Ohms ≤1 second Magnetic metals 0.2 mA (continuous) The 0703-1602-99 TrueTILT™ single axis, mid-range electrolytic tilt sensor has a robust all metal construction providing durability while maintaining superior tolerances and sensor to sensor performance. It is an economical sensor ideal for a versatile range of applications in many sectors. Applications View a full list of applications on The Fredericks Company website at www.frederickscom.com. Physical Characteristics Length Width Height Hole Center Hole Diameter Lead Spacing Lead Diameter Lead Length Weight Construction machinery and equipment Railway monitoring Laser leveling systems Aerial platform level control, monitor, and alarm Mining machinery and equipment Agricultural machinery and equipment Linear Range Very low power consumption Extremely long life Minimal drift over lifetime compared to MEMS devices Excellent resolution and repeatability Superior performance in extreme temperatures and environments Excellent customer support Manufactured in the United States of America Operating Range RoHS Compliant See The Fredericks Company website for a list of term definitions. email: [email protected]

 Open the catalog to page 1
TrueTILT? Mid-Range Single Axis, Linear Output, Electrolytic Tilt Sensor-2

TrueTilt™ Single Axis Mid-Range Electrolytic Tilt Sensor Dimensional Drawings When using an excitation circuit not designed by The Fredericks Company, ensure that no direct current is passed through the sensor. Direct current will lead to sensor damage, output drift, and general The 0703-1602-99 and all sensors in the TrueTilt™ series must be mounted horizontally (parallel to the surface of the earth and perpendicular to the force of gravity). For best performance, isolate the sensor from vibrations when mounting it. Further information on sensor basics is provided on The Fredericks Company website...

 Open the catalog to page 2

All The Fredericks Company catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.