1. Catalogs
  2. The Fredericks Company
  3. Televac 7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor

Televac 7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor

Televac 7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor

Televac 7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor

Product catalog summary
Operating Specifications
The 7FC cold cathode sensor operates within a range of 1 x 10-11 to 1 x 10-2 Torr. It is controller-dependent for analog output and supply voltage, and can be mounted in any orientation. The sensor is calibrated using dry air or nitrogen and can withstand overpressure up to 150 PSI. It operates effectively between 0° to +50° C and can be stored between -20° to +70° C. The bakeout temperature is 200° C, with a response time of ≤ 10 ms and an accuracy of ±0.2 decade from 1 x 10-9 to 1 x 10-2 Torr.
Physical Characteristics
The sensor features SHV5 electrical connections, weighs 944 g (2.08 lbs), and its dimensions are available in the dimensional drawings. Materials exposed to vacuum include stainless steel, ceramic, and copper.
Benefits
The 7FC sensor is cleanable for extended use, mountable in any orientation, resistant to gas inrushes, and interchangeable with models 7E, 7F, and 7FCS. It has minimal stray magnetic fields and is supported by excellent customer service. It is designed and manufactured in the USA.
Description
The 7FC sensor measures absolute pressure by ionizing gas in a magnetic field, offering resistance to gas inrushes unlike hot filament sensors. It is compatible with Televac MM200 or MC300 controllers for a comprehensive vacuum measurement solution.
Ratings and Compliance
The sensor is RoHS compliant.
Ordering Information
The part number for the 7FC sensor is 2-2146-052. Various cables and configurations are available, including standard, high temperature, triaxial, and radiation-resistant cables, with lengths ranging from 10 ft to 50 ft.
Related Products
The document also references the 7E sensor and MM200 and MC300 controllers, which offer various features for vacuum measurement and control.
Contact Information
For more information, contact Televac at The Fredericks Company, 2400 Philmont Avenue, Huntingdon Valley, PA 19006, or visit their website at www.televac.com.
See more

Catalog excerpts

Televac 7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor-1

7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor Part Number: 2-2146-052 Description Operating Range Analog Output Supply Voltage Mounting Orientation Calibration Medium Overpressure Analog Output Resolution Operating Temperature Storage Temperature Bakeout Temperature Response Time Accuracy 1 x 10 to 1 x 10 Torr Controller-dependent Controller-dependent Any Dry air or nitrogen 150 PSI Controller-dependent 0° to +50° C -20° to +70° C 200° C < 10 ms The 7FC cold cathode sensor has a measurement range from 1 x 10-11 up to 1 x 10-2 Torr. It indirectly measures absolute pressure by ionizing gas in the presence of a magnetic field. Unlike hot filament sensors, the 7FC is resistant to inrushes of gas. The design of this sensor allows for easy disassembly enabling quick cleaning and extended use. The 7FC can be operated by the Televac MM200 or MC300 rack mountable controllers. These controllers automatically operate the cold cathode to provide a full range vacuum measurement solution when the 7FC is used in conjunction with rough vacuum sensors. Physical Characteristics Analog Output Behavior (MM200) Electrical Connections SHV5 Weight 944 g (2.08 lbs) Dimensions See dimensional drawings Stainless Steel Ceramic Copper • Cleanable for extended sensor lifetime • Mountable in any orientation • Resistant to inrushes of gas • Interchangeable with 7E, 7F, 7FCS • Minimal stray magnetic field • Excellent customer support • Designed and manufactured in the United States of America • RoHS compliant 1 See the Televac website at www.televac.com for a list of definitions for terms used in the operating specifications. All test data was acquired at 23° C.

 Open the catalog to page 1
Televac 7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor-2

7FC Double Inverted Magnetron Cleanable Cold Cathode Sensor Part Number: 2-2146-052 Ordering Information Dimensional Drawings 7FC Cold Cathode Sensor Standard Cables High Temperature Cables (200 C) Triaxial Cables (MM200 only) Radiation Resistant Cables Cable Length 10 ft (3 m) 20 ft (6.1 m) 35 ft (10.6 m) 50 ft (15.2 m)_ 7E Double Inverted Magnetron Cold Cathode Sensor - This sensor has a measurement range from 1 x 10-8 up to 1 x 10-2 Torr. It indirectly measures absolute pressure by ionizing gas in the presence of a magnetic field. Unlike hot filament sensors, the 7E is resistant to inrushes...

 Open the catalog to page 2

All The Fredericks Company catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.