1. Catalogs
  2. The Fredericks Company
  3. Televac 2A NASA Mini Thermocouple Sensor

Televac 2A NASA Mini Thermocouple Sensor

Televac 2A NASA Mini Thermocouple Sensor

Televac 2A NASA Mini Thermocouple Sensor

Product catalog summary
Operating Specifications
The 2A NASA Mini Thermocouple Sensor operates within a range of 1 x 10-3 to 20 Torr. It is designed to work with various Televac controllers, with a maximum voltage of 5 V and power consumption of 55 mW. The sensor can withstand a maximum filament temperature of 250°C and is operable in any orientation. It is calibrated using dry air or nitrogen and can handle overpressure up to 125 PSIG. The operating and storage temperature range is -54° to +93°C, with a bakeout temperature of 400°C. The response time is ≤ 1 second, and accuracy varies across different pressure ranges.
Physical Characteristics
The sensor features a 4-pin electrical connection compatible with Bendix PC-06A-8-4S SR and weighs 28 grams. Materials exposed to vacuum include gold, glass, stainless steel, Tophet, and Cupron.
Benefits
The sensor is designed to NASA specifications, offering reliable vacuum indication and performance with a rugged, compact design. It requires no calibration and is supported by excellent customer service. It is manufactured in the USA.
Description
The 2A NASA Mini sensor measures absolute pressure by detecting thermal dissipation of a filament. It is compatible with several Televac controllers and has less than 25% of the internal volume of the Televac 2A vacuum sensor.
Related Products
The document also mentions related products such as the 2A VacuMini Thermocouple Sensor and the 4A Convection Sensor, each with specific measurement ranges and features. The MM200 Vacuum Sensor Controller is highlighted for its compatibility with various sensor types and modular design.
Contact Information
For more information, contact Televac at The Fredericks Company, 2400 Philmont Avenue, Huntingdon Valley, PA 19006, or visit their website at www.televac.com.
See more

Catalog excerpts

Televac 2A NASA Mini Thermocouple Sensor-1

2A NASA Mini Thermocouple Sensor Part Number: 2-2100-31 Operating Specifications1! Gold Glass Stainless Steel Tophet Cupron The 2A NASA Mini thermocouple sensor has a measurement range from 1 x 10-3 up to 20 Torr. It indirectly measures absolute pressure by detecting the thermal dissipation of a filament. It can withstand high temperature bakeouts up to 400° C. It also has less than 25% of the internal volume of the Televac 2A vacuum sensor. The 2A NASA Mini can be operated by several Televac controllers, including the MM200, MC300, B2A, Compact 2A, Vacuguard, and MV2A. • RoHS compliant • Designed and manufactured to NASA specifications • Reliable, high quality vacuum indication and performance • Rugged and simple construction • Compact design • Operation in any physical orientation • No calibration required • Excellent customer support • Designed and manufactured in the United States of America 1 See the Televac website at www.televac.com for a list of definitions for terms used in the operating specifications. All test data was acquired at 23° C.

 Open the catalog to page 1
Televac 2A NASA Mini Thermocouple Sensor-2

2A NASA Mini Thermocouple Sensor Part Number: 2-2100-31 Ordering Information Dimensional Drawings 2A NASA Mini Sensor 1/8” NPT Stainless Steel Visit the Televac website at www.televac.com for a full list of vacuum instruments compatible with the 2A NASA Mini Sensor. Related Products 2A VacuMini Thermocouple Sensor – The VacuMini is a commercial version of Televac’s 2A NASA sensor. This thermocouple sensor has a -3 measurement range from 1 x 10 up to 20 Torr. It indirectly measures absolute pressure by detecting the thermal dissipation of a filament. It includes a tethered cap that provides IP67...

 Open the catalog to page 2

All The Fredericks Company catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.