Micro-Arc 0728-1025-99 Ceramic - 1

DATA SHEET Operating Specifications Description The 0728-1025-99 ”Micro-arc” uses ceramic construction technology. This wide-angle sensor is manufactured to precise tolerances for extreme sensor-to-sensor sensitivity and repeatability. The 0728-1025-99-sensor features linear output to ±75°, good vibration resistance, and superior cross axis properties. Glass sealing technologies allow for operation in a wider temperature range. • Angle Range • Resolution • Null Repeat Applications Include » » » » » Off Road and Construction Vehicles Medical Instruments Navigational and GPS Compensation Robotic and Automotive Applications Oceanographic Instrumentation Operating Range (max.) ± 85° Linear Range (10 to 90%) ± 75° Linearity ±3% Null Voltage ≤0.025 Volts Null Current(max.) 0.2 mA (continuous) Null Impedance (nom) 10.0 K Ohms (25°C) (measured left to right electrode)see fig. 2 Repeatability ±.05 ° Resolution < 0.2 arc minutes Symmetry (typ) < 5% Mech. Crosstalk / Deg. (typ) 0.005° Operating Temperature -20° C to +100° C Storage Temperature -20° C to +100° C Time Constant (1) 2 < 100 msec Materials non-magnetic Note: Null Impedance of the sensor may be modified to individual requirements upon special order. Physical Dimensions Height Width Diameter – mounting hole Wire length (min) OUTPUT SENSITIVITY Sensor Test Circuitry Descrition of Test Values AC input voltage = Null Current (max) times Null Impedance (nom) Eout = Angle of tilt from null (Direction of tilt determined by phase of Eout) OUTPUT (percentage) Tests were conducted by exciting the left and right electrodes with an AC signal of 400 Hz and an rms voltage to produce the maximum current at null as per operating specifications. Output readings are taken between the center electrode and the center of the balanced resistors R1 and R2. Tests were conducted at a temperature of +25° C. See sensor test circuitry in figure 3. Output curve is shown in figure 1. TILT ANGLE (degrees) R1 =R2 = ½ Null Impedance (nom) Caution!-Ensure that all test and operating circuits are entirely free of direct current. Direct current will cause level damage and/or instability. The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067 Tel: 215.947.2500 l Fax: 215.947.7464 l Email: sales@frederickscom.com l ww

Open the catalog to page 1

All The Fredericks Company catalogs and technical brochures

Archived catalogs