DATA SHEET Operating Specifications Description The 0737-0604-99 Sensor has been used successfully in applications that demand ultra high accuracy, excellent null repeatability, and a linear output. Long term stability over its angle and temperature range is a distinctive characteristic of this sensor. The hermetic glass to metal construction and platinum (platinized) electrodes guarantee a long operating life and stable operating characteristics. Angle Range Resolution Null Repeat Applications Include Geophysical Monitoring Construction Laser Instruments and Transits Aircraft Avionics Machine Tool Leveling Medical Positioning and Monitoring Physical Dimensions Vial length Vial Diameter Lead Length Impedance of the electrode may be changed to limit null current. 2 Viscosity of the electrolyte may be modified to meet individual requirements for time constant or vibration. Sensor Test Circuitry Tests were conducted by exciting the left and right electrodes with an AC signal of 400 Hz and an RMS voltage to produce the maximum current at null as per operating specifications. Output readings are taken between the center electrode and the center of the balanced resistors R1 and R2. Tests were conducted at a temperature of +25 C. See sensor test circuitry in figure 3. Output curve is shown in figure 1. OUTPUT SENSITIVITY Figure 1 100 80 PERCENT OUTPUT 30’ Operating Range (max.) Linear Range ± 15’ Null Voltage ≤0.030 Volts Null Current(max.) 5.0 mA (continuous) Null Impedance (nom)1 3500 Ohms(25°C) (measured left to right electrode) see fig 2 Null Repeatability < 0.5 arc seconds Resolution < 0.05 arc seconds Symmetry (typ) ≤20% -20 C to +100 C Operating Temperature -50 C to +100 C Storage Temperature Time Constant (1)2 < 500 msec Materials non-magnetic Temperature Coefficient 0.05%/°C max. at null when properly mounted Descrition of Test Values IMPEDANCE / TEMPERATURE Figure 2 AC input voltage = Null Current (max) times Null Impedance (nom) R1 =R2 = ½ Null Impedance (nom) Caution!-Ensure that all test and operating circuits are entirely free of direct current. Direct current will cause level damage and/or instability. IMPEDANCE (Ohms) Eout = Angle of tilt from null (Direction of tilt determined by phase of Eout) The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067 Tel: 215.947.2500 l Fax: 215.947.7464 l Email: sales@frederickscom.com l www.frederickscom.com 0737-0604-99data sheet Revision: A
Open the catalog to page 1All The Fredericks Company catalogs and technical brochures
-
Televac br5003
6 Pages
-
Televac MP7FR Cold Cathode
2 Pages
-
Televac MX4A Convection
2 Pages
Archived catalogs
-
0711-0768-99-0719-1143-99_ds
2 Pages
-
Single Axis Narrow Angle
1 Pages
-
2 A Thermocouple Sensor
2 Pages
-
Glass Mid-Range 0715-4101-99
1 Pages
-
Glass Mid-Range 0714-5701-99
1 Pages
-
Glass Mid-Range 0737-0101-99
1 Pages
-
0703-0703-99 TrueTilt
2 Pages
-
Electrolytictilt
4 Pages