Product catalog summary
Operating Specifications
The sensor operates within a maximum range of 10 degrees and a linear range of ±5 degrees. It has a null voltage of ≤0.030 Volts and a maximum null current of 5.0 mA. The nominal null impedance is 3600Ω at 25°C, with a null repeatability of less than 2.0 arc seconds and a resolution of less than 1.0 arc second. The symmetry at half scale is a maximum of 5%. The operating temperature range is from -40°C to +80°C, and the storage temperature range is from -50°C to +100°C. The time constant is less than 500 ms, and the materials used are non-magnetic with a temperature coefficient at null of 0.02%/°C max.
Physical Dimensions
The vial length is a maximum of 1.13 inches (28.70mm), the vial diameter is a maximum of 0.320 inches (8.13mm), and the lead length is a maximum of 15.0 inches (381mm), with custom lead lengths available.
Applications
The sensor is suitable for geophysical monitoring, construction laser instruments and transits, aircraft avionics, machine tool leveling, and medical positioning and monitoring.
Performance Characteristics
The sensor is noted for its ultra-high accuracy, excellent null repeatability, mid-range angle measurement, and linear output. It offers long-term stability over its angle and temperature range, with hermetic glass to metal construction and platinum electrodes ensuring a long operating life and stable characteristics.
Test Circuitry
Tests were conducted using an AC signal of 400 Hz to excite the left and right electrodes, with output readings taken between the center electrode and the center of balanced resistors R1 and R2. The tests were conducted at a temperature of +25°C. It is crucial to ensure that all test and operating circuits are free of direct current to prevent damage or instability.
Figures
Figure 1 illustrates the output sensitivity as a function of tilt angle, while Figure 2 shows impedance versus temperature.
See more

Catalog excerpts

Glass Mid-Range 0737-0101-99-1

DATA SHEET Operating Specifications Description The 0737-0101-99 Sensor has been used successfully in applications that demand ultra high accuracy, excellent null repeatability, mid-range angle measurement and a linear output. Long term stability over its angle and temperature range is a distinctive characteristic of this sensor. The hermetic glass to metal construction and platinum electrodes guarantee a long operating life and stable operating characteristics. Angle Range Resolution Null Repeat Applications Include » » » » » Geophysical Monitoring Construction Laser Instruments and Transits Aircraft Avionics Machine Tool Leveling Medical Positioning and Monitoring Measured left to right electrode, Impedance of the electrode may be changed to limit null current. 2 Viscosity of the electrolyte may be modified to meet individual requirements for time constant or vibration. OUTPUT SENSITIVITY Figure 1 Physical Dimensions 1.13” max (28.70mm) 0.320”max (8.13mm) 15.0” max (381mm) custom lead length available Sensor Test Circuitry Tests were conducted by exciting the left and right electrodes with an AC signal of 400 Hz and an RMS voltage to produce the maximum current at null as per operating specifications. Output readings are taken between the center electrode and the center of the balanced resistors R1 and R2. Tests were conducted at a temperature of +25 C. See sensor test circuitry in figure 3. Output curve is shown in figure 1. Vial length Vial Diameter Lead Length 10 ± 5° ≤0.030 Volts 5.0 mA (continuous) 3600Ω@25°C < 2.0 arc seconds < 1.0 arc seconds 5% max. -40 C to +80 C -50 C to +100 C < 500 ms non-magnetic 0.02%/°C max. Operating Range (max.) Linear Range Null Voltage Null Current(max.) Null Impedance (nom)1 Null Repeatability Resolution Symmetry @ ½ scale Operating Temperature Storage Temperature Time Constant 2 Materials Temperature Coefficient at Null TILT ANGLE (degrees) Descrition of Test Values IMPEDANCE vs. TEMPERATURE Figure 2 AC input voltage = Null Current (max) times Null Impedance (nom) Eout = Angle of tilt from null (Direction of tilt determined by phase of Eout) Caution!-Ensure that all test and operating circuits are entirely free of direct current. Direct current will cause level damage and/or instability. The Fredericks Company l 2400 Philmont Ave ● HuntingdonValley, PA 19006-0067 Tel: 215.947.2500 l Fax: 215.947.7464 l Email: [email protected] l www.frederickscom.com 0737-0101-99data sheet Revision: A

 Open the catalog to page 1

All The Fredericks Company catalogs and technical brochures

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.