Catalog excerpts

VISUAL LEVEL The visual level gauges allow the liquid level to be checked in a clear and precise way at any time, in addition to the possibility of having electric signals.
Open the catalog to page 1
TL VISUAL LEVEL C/C DISTANCE 76-127-254 MM The visual level gauges TL series allow the liquid level to be checked in a clear and precise way at any time. PRINCIPLE OF OPERATION: The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. OPTIONS: - C/C distance 76, 127, 254 mm interchangeable with almost every level visual marketing - Body Transparent polyamide based TR 55 LX (Grilamid TM) or polycarbonate. TECHNICAL ADVANTAGES: - Constant and continuous indication of the level of...
Open the catalog to page 2
REAR TAB CONTRAST ON WHITE BACKGROUND BIMETALLIC THERMOMETER “TS“ DOUBLE SCALA °C (0-120) AND °F (30-250)
Open the catalog to page 3
TL/E LEVEL ELECTRICAL CHARACTERISTICS The visual level gauges TL series allow the liquid level to be checked in a clear and precise way at any time. PRINCIPLE OF OPERATION: The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. OPTIONS: - C/C distance 76, 127, 254 mm interchangeable with almost every level visual marketing - Body Transparent polyamide based TR 55 LX (Grilamid TM) or polycarbonate. CHEMICAL RESISTANCE: The polymer used is a compound based on polyamide 12. The...
Open the catalog to page 4
CHARACTERISTICS OF LEVEL GAUGE WITH THERMOSTAT / PT 100 CHARACTERISTICS OF ELECTRIC LEVEL GAUGE WITH THERMOSTAT / PT 100 In addition to the electric level gauge, the Top Level can provide temperature signalling by means of a PT 100 (-50°C +150°C) or the insertion of a preset thermostat. In addition to the already mentioned qualities of the TOP LEVEL, there is also the possibility of having a minimum electric signal together with the temperature signal of a thermostat or a PT 100, all in a single level gauge, and on a single connector. To facilitate the passage of heat, from the tank through...
Open the catalog to page 5
BIMETALLIC THERMOMETER “TS“ DOUBLE SCALE °C (0-120) AND °F (30-250) Maximum pressure: see page 33 Maximum tightening torque: 10 Nm
Open the catalog to page 6
LV MULTICONTROL RANGE VISUAL LEVEL GAUGES 28 M10 OR M12 SCREWS RECESSED IN THE BODY 13 “U“ PROTECTION SCREEN WITH GRADUATED SCALE SCALE STAMPED ON ALUMINIUM FOR PERFECT CONTRAST WITH LIQUID The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The level gauges can be...
Open the catalog to page 7
VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L = 15mm MAX SERIGRAPHY ON REQUEST ON CUSTOMUR DRAWING Maximum pressure: see page 33 Maximum tightening torque: 10 Nm
Open the catalog to page 8
LV-T VISUAL LEVEL GAUGES WITH INTERNAL THERMOMETER 28 M10 OR M12 SCREWS RECESSED IN THE BODY 13 “U“ PROTECTION SCREEN WITH GRADUATED SCALE SCALE STAMPED ON ALUMINIUM FOR PERFECT CONTRAST WITH LIQUID The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The LV/T has a...
Open the catalog to page 9
VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L 15mm MAX SERIGRAPHY ON REQUEST ON CUSTOMER DRAWING Maximum pressure: see page 33 Maximum tightening torque: 10 Nm
Open the catalog to page 10
LV/Ts VISUAL LEVEL GAUGES WITH EXTHERNAL BIMETALLIC THERMOMETER 28 M12 SCREWS RECESSED IN THE TUBE HEAD SCALE STAMPED ON ALLUMINIUM FOR PERFECT CONTRAST WITH LIQUID “U“ PROTECTION SCREEN WITH GRADUATED SCALE The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The LV/Ts...
Open the catalog to page 11
VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L 15mm SERIGRAPHY ON REQUEST ON CUSTOMER DRAWIN Maximum pressure: see page 33 Maximum tightening torque: 10 Nm
Open the catalog to page 12
LV/E1 VISUAL LEVEL GAUGES WITH MINIMUM LEVEL SIGNAL The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The level gauges can be equipped with tap that stop the flow of liquid from the tank to the gauge. The C/C distances of 127 ÷ 4000 mm supplied meet the needs of all...
Open the catalog to page 13
MAX SERIGRAPHY ON REQUEST ON CUSTOMUR DRAWING VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L = 15mm 50 BIMETAL THERMOMETER “TS“ WITH DOUBLE SCALE °C (0-120) AND °F (30-250) Maximum pressure: see page 33 Maximum tightening torque: 10 Nm
Open the catalog to page 14
LV/E2 VISUAL LEVEL GAUGES WITH MINIMUN AND MAXIMUN SIGNAL The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The level gauges can be equipped with tap that stop the flow of liquid from the tank to the gauge. The C/C distances of 127 ÷ 4000 mm supplied meet the needs of...
Open the catalog to page 15All Fratelli Giacomello catalogs and technical brochures
-
RAPID LEVEL 2024
22 Pages
-
IEG ATEX 2024
3 Pages
-
ELECTROMAGNETIC LEVELS 2024
57 Pages
-
LVC 2024
4 Pages
-
LV/E1+S1..S2..S3..
3 Pages
-
LV-T
3 Pages
-
SMALL LEVELS
12 Pages
-
FLOWSWITCH
7 Pages
-
PLUGS
17 Pages
-
LUN/LMU
3 Pages
-
LV/M
2 Pages
-
TL VISUAL LEVEL
3 Pages
-
ATEX
5 Pages
-
LMA-PC
2 Pages
-
IEG-U1F
2 Pages
-
IEG-N1F
2 Pages
-
TCSL
2 Pages
-
TCSL/P
2 Pages
-
temperature probe T+T
3 Pages
-
IEG-FCH1
2 Pages
-
IEG?S/STEEL-1M-SF 3/8
2 Pages
-
Visual level gauges
3 Pages
-
Flow switch
2 Pages
-
Propeller Control
3 Pages
-
Plastic Plug
2 Pages
Archived catalogs
-
IEG ATEX
5 Pages
-
ELECTROMAGNETIC LEVELS
32 Pages
-
LVC
4 Pages
-
Rapid level
18 Pages
-
RAPID LEVEL
4 Pages