Visual level
26Pages

{{requestButtons}}

Catalog excerpts

Visual level - 1

VISUAL LEVEL The visual level gauges allow the liquid level to be checked in a clear and precise way at any time, in addition to the possibility of having electric signals.

Open the catalog to page 1
Visual level - 2

VISUAL LEVEL C/C DISTANCE 76-127-254 MM The visual level gauges TL series allow the liquid level to be checked in a clear and precise way at any time. PRINCIPLE OF OPERATION: The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. OPTIONS: - C/C distance 76, 127, 254 mm interchangeable with almost every level visual marketing - Body Transparent polyamide based TR 55 LX (Grilamid TM) or polycarbonate. TECHNICAL ADVANTAGES: - Constant and continuous indication of the level of the...

Open the catalog to page 2
Visual level - 3

BIMETALLIC THERMOMETER "TS" DOUBLE SCALA °C (0-120) AND °F (30-250) BODY MATERIAL SCREWS MATERIAL NICKEL PLATED BRASS M10 NICKEL PLATED BRASS Ml 2 WrTH LOWER BIMETALLIC THERMOMETER (WITH BRASS NICKEL SCREW Ml2) WITH TWO GALVANIZED STEEL LOCKNUTS WITH TWO STAINLESS STEEL LOCKNUTS F.lli Giacomello

Open the catalog to page 3
Visual level - 4

LEVEL ELECTRICAL CHARACTERISTICS The visual level gauges TL series allow the liquid level to be checked in a clear and precise way at any time. PRINCIPLE OF OPERATION: The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. OPTIONS: - C/C distance 76, 127, 254 mm interchangeable with almost every level visual marketing - Body Transparent polyamide based TR 55 LX (Grilamid TM) or polycarbonate. CHEMICAL RESISTANCE: The polymer used is a compound based on polyamide 12. The Top...

Open the catalog to page 4
Visual level - 5

In addition to the electric level gauge, the Top Level can provide temperature signalling by means of a PT 100 (-50°C +150°C) or the insertion of a preset thermostat. To facilitate the passage of heat, from the tank through the hollow screw to the thermostat / PT 100, a metal plate is inserted inside the level gauge to conduct the heat of the liquid faster and with less dissipation. In conjunction with the thermostat / PT 100, a cap is fitted standard on the bottom screw to prevent heat loss to the outside. Complete resin coating in the cavity containing the thermostat provides better heat...

Open the catalog to page 5
Visual level - 6

SCHEME OF ORDER BIMETALLIC THERMOMETER "TS" DOUBLE SCALE °C (0-120) AND °F (30-250) Maximum pressure: see page 33 Maximum tightening torque: 10 Nm 27 LEVEL CHARACTERISTICS C/C DISTANCE SCREWS MATERIAL ELECTRICAL CONTACT IN ABSENCE OF LIQUID THERMOSTAT CHARACTERISTICS BODY MATERIAL THERMOMETER LOCKNUT ELECTRICAL NICKEL PLATED BRASS Ml0 (ONLY FOR E) WrTHOJT CONTACT (ONLYP-T) WITHOUT THERMOSTAT (ONLY E-P-PE) BIMETALLIC THERMOMETER NICKEL PLATED BRASS Ml2 WrTH LOWER BIMETALLIC THERMOMETER (WrTH BRASS NICKEL SCREW Ml2) WITH TWO GALVANIZED STEEL LOCKNUTS WITH TWO STAINLESS STEEL LOCKNUTS

Open the catalog to page 6
Visual level - 7

LV MULTICONTROL RANGE VISUAL LEVEL GAUGES 28 M10 OR M12 SCREWS RECESSED IN THE BODY 13 “U“ PROTECTION SCREEN WITH GRADUATED SCALE SCALE STAMPED ON ALUMINIUM FOR PERFECT CONTRAST WITH LIQUID The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The level gauges can be...

Open the catalog to page 7
Visual level - 8

VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L = 15mm MAX SERIGRAPHY ON REQUEST ON CUSTOMUR DRAWING Maximum pressure: see page 33 Maximum tightening torque: 10 Nm

Open the catalog to page 8
Visual level - 9

LV-T VISUAL LEVEL GAUGES WITH INTERNAL THERMOMETER 28 M10 OR M12 SCREWS RECESSED IN THE BODY 13 “U“ PROTECTION SCREEN WITH GRADUATED SCALE SCALE STAMPED ON ALUMINIUM FOR PERFECT CONTRAST WITH LIQUID The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The LV/T has a...

Open the catalog to page 9
Visual level - 10

Maximum pressure: see page 33 Maximum tightening torque: 10 Nm SCREWS MATERIAL GALVANISED STEEL NICKEL PLATED BRASS NICKEL PLATED BRASS GALVANISED STEEL NICKEL PLATED TUBE MATERIAL WITH LOWER TAP NICKEL PLATED BRASS L= 50 mm WITH TWO TAPS NICKEL PLATED BRASS L= 50 wrrH Ml 2 S/STEEL LOWER L= 50 mm

Open the catalog to page 10
Visual level - 11

LV/Ts VISUAL LEVEL GAUGES WITH EXTHERNAL BIMETALLIC THERMOMETER 28 M12 SCREWS RECESSED IN THE TUBE HEAD SCALE STAMPED ON ALLUMINIUM FOR PERFECT CONTRAST WITH LIQUID “U“ PROTECTION SCREEN WITH GRADUATED SCALE The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The LV/Ts...

Open the catalog to page 11
Visual level - 12

VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L 15mm SERIGRAPHY ON REQUEST ON CUSTOMER DRAWIN Maximum pressure: see page 33 Maximum tightening torque: 10 Nm

Open the catalog to page 12
Visual level - 13

LV/E1 VISUAL LEVEL GAUGES WITH MINIMUM LEVEL SIGNAL The visual level gauges allow the liquid level to be checked in a clear and precise way at any time. The principle used is that of communicating vessels: the liquid goes through the level gauge by means of hollow screws, showing the user the exact point inside the tank. Through a full range of components our level gauges can meet the most particular needs, at a limited cost. The level gauges can be equipped with tap that stop the flow of liquid from the tank to the gauge. The C/C distances of 127 ÷ 4000 mm supplied meet the needs of all...

Open the catalog to page 13
Visual level - 14

SERIGRAPHY ON REQUEST ON CUSTOMUR DRAWING VISIBLE TUBE IN LATERAL POSITION WITH LOW PROFILE L = 15mm SCREWS MATERIAL NICKEL PLATED NICKEL PLATED NICKEL PLATED NICKEL PLATED ELECTRICAL CONTACT POSITION ELECTRICAL CONTACT TUBE MATERIAL HEAD MATERIAL rq CLOSED IN ABSENCE OF LIQUID OPEN IN ABSENCE OF LIQUID NBRWm-l S/STEEL SPIRAL (BACK) F.lli Ciacomello Maximum pressure: see page 33 Maximum tightening torque: 10 Nm LV/E1 WITH LOWER TAP NICKEL PA7ED BRASS L= 50 mm WITH TWO TAPS NICKEL PATED WITH LOWER THERMOMETER external bimetallic (Includes Ml 2-B) (Excludes R1-R2-R3-R4) WITH SERIGRAPHY ON...

Open the catalog to page 14

All Fratelli Giacomello catalogs and technical brochures

  1. LV-T

    3 Pages

  2. SMALL LEVELS

    12 Pages

  3. FLOWSWITCH

    7 Pages

  4. PLUGS

    17 Pages

  5. IEG ATEX

    5 Pages

  6. LUN/LMU

    3 Pages

  7. LV/M

    2 Pages

  8. ATEX

    5 Pages

  9. LVC

    4 Pages

  10. Rapid level

    18 Pages

  11. LMA-PC

    2 Pages

  12. IEG-U1F

    2 Pages

  13. IEG-N1F

    2 Pages

  14. TCSL

    2 Pages

  15. TCSL/P

    2 Pages

  16. IEG-FCH1

    2 Pages

  17. Flow switch

    2 Pages

  18. Plastic Plug

    2 Pages

Archived catalogs

  1. RAPID LEVEL

    4 Pages