1. Catalogs
  2. Fratelli Giacomello
  3. ELECTROMAGNETIC LEVELS 2024

ELECTROMAGNETIC LEVELS 2024
1 /57Pages

ELECTROMAGNETIC LEVELS 2024

ELECTROMAGNETIC LEVELS 2024
1 /57Pages

Catalog excerpts

ELECTROMAGNETIC LEVELS 2024-1

ELECTROMAGNETIC LEVELS Precision and functionality, control points single or multiple, different materials to meet the various requirements of application.

 Open the catalog to page 1
ELECTROMAGNETIC LEVELS 2024-2

FITTING: The indicator must be fitted in the vertical position, and the float must be at least 35mm from ferrous surfaces (walls, tanks, etc.). The tight‘s flange is ensured by a flat synthetic rubber gasket. OPERATION: When the float of the indicator encounters the Reed switch incorporated in the tube at the pre-established distances, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or disconnecting any electrical equipment connected to it. THREADED PLUG THREADED PLUG USE: Made to ensure, with maximum...

 Open the catalog to page 2
ELECTROMAGNETIC LEVELS 2024-3

CONNECTOR THREADED PLUG THREADED PLUG USE: Made to ensure, with maximum safety, the minimum or maximum level of liquids in tanks and hydraulic power packs containing mineral oils with viscosity not higher than 220 cSt; also suitable for gas oil and other non-corrosive and inflammable liquids. OPERATION: When the float of the indicator encounters the Reed switch at the pre-established point, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or activating or disconnecting any electrical equipment connected...

 Open the catalog to page 3
ELECTROMAGNETIC LEVELS 2024-4

IEG-TQ101 18x1,5 IEG-TQ102 18x1,5 ELECTROMAGNETIC LEVEL INDICATORS WITH SPST OR SPDT CONTACTS M18x1,5 CONNECTION FLOAT IN NYLON (SPANSIL OR POLYPROPYLENE ON REQUEST) OPERATION: When the float of the indicator encounters the Reed switch incorporated in the tube at the preestablished distances, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or disconnecting any electrical equipment connected to it. FITTING: The indicator must be fitted in the vertical position, and the float must be at least 35mm from...

 Open the catalog to page 4
ELECTROMAGNETIC LEVELS 2024-5

BRASS TUBE Ø10 MIN. FLOAT USE: Made to ensure, with maximum safety, the minimum or and empty levels of liquids in tanks, and hydraulic power packs containing mineral oils with viscosity not higher than 220 cSt. and for all non-corrosive and inflammable liquids. OPERATION: IEG-TQ10MM: when the float of the indicator encounters the Reed switch incorporated in the tube at the pre-established distances, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or disconnecting any electrical equipment connected...

 Open the catalog to page 5
ELECTROMAGNETIC LEVELS 2024-6

IEG-TQ071 18x1,5 IEG-TQ072 18x1,5 ELECTROMAGNETIC LEVEL INDICATORS WITH SPST OR SPDT CONTACTS M18x1,5 CONNECTION OPERATION: When the float of the indicator encounters the Reed switch incorporated in the tube at the pre-established distances, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or disconnecting any electrical equipment connected to it. USE: Made to ensure, with maximum safety, the minimum or and empty levels of liquids in tanks, and hydraulic power packs containing mineral oils with viscosity...

 Open the catalog to page 6
ELECTROMAGNETIC LEVELS 2024-7

IEG-TQ07MM 18x1,5 ELECTROMAGNETIC LEVEL INDICATORS WITH TWO CONTACTS AND M18x1,5 CONNECTION USE: Made to ensure, with maximum safety, the minimum levels of liquids in tanks, and hydraulic power packs containing mineral oils with viscosity not higher than 220 cSt. and for all non-corrosive and inflammable liquids. OPERATION: When the float of the indicator encounters the Reed switch incorporated in the tube at the pre-established distances, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or disconnecting...

 Open the catalog to page 7
ELECTROMAGNETIC LEVELS 2024-8

IEG-BT1 3/8 IEG-BT2 3/8 ELECTROMAGNETIC LEVEL INDICATORS WITH SPST OR SPDT CONTACTS AND 3/8” GAS CONNECTION USE: Made to ensure, with maximum safety, the minimum or and empty levels of liquids in tanks, and hydraulic power packs containing mineral oils with viscosity not higher than 220 cSt. and for all non-corrosive and inflammable liquids. FLOAT IN NYLON (SPANSIL OR POLYPROPYLENE ON REQUEST) OPERATION: When the float of the indicator encounters the Reed switch incorporated in the tube at the pre-established distances, the contact activated by the magnet housed in the float opens or closes,...

 Open the catalog to page 8
ELECTROMAGNETIC LEVELS 2024-9

USE: Made to ensure, with maximum safety, the minimum or and empty levels of liquids in tanks, and hydraulic power packs containing mineral oils with viscosity not higher than 220 cSt. and for all non-corrosive and inflammable liquids. OPERATION: IEG-BTMM: when the float of the indicator encounters the Reed switch incorporated in the tube at the pre-established distances, the contact activated by the magnet housed in the float opens or closes, thus obtaining the possibility of sending a luminous or acoustic signal or disconnecting any electrical equipment connected to it. The levels IEG-BTMV...

 Open the catalog to page 9
ELECTROMAGNETIC LEVELS 2024-10

IEG-TC1 IEG-TC2 ELECTROMAGNETIC LEVEL INDICATOR WITH ONE CONTACT AND 1” GAS CONNECTION USE: Built to ensure the minimum or maximum level of liquids in tanks with maximum safety. Suitable for tanks containing liquids compatible with the brass tube, such as hydraulic or lubricating oils (provided their density does not exceed 220 cSt), petroleum, etc. OPERATION: When the float of the indicator in its travel encounters the built-in Reed switch at the pre-established point, the contact, actived by the magnet housed in the float, opens or closes, thus obtaning the possibility of sending a luminous...

 Open the catalog to page 10
ELECTROMAGNETIC LEVELS 2024-11

DATA AND TECHNICAL ORDER FLOATS ELECTRICAL CONNECTIONS ELECTRICAL DATA

 Open the catalog to page 11
ELECTROMAGNETIC LEVELS 2024-12

ELECTRICAL CONNECTIONS

 Open the catalog to page 12
ELECTROMAGNETIC LEVELS 2024-13

ELECTRICAL CONNECTION TABLE - TC1 & TC2 Connector CE EN 175301-803-A IP65 PG9/11 (electrical connection 0) Circular Connector 5P M12 EN 60529 IP67 (electrical connection 5) Aluminum Head IP68 (electrical connection 1) LIGHT BLUE (N.C. IN PRES.) 3 POLES + T SPST (TC1) SPDT (TC2) B N.B.: the nature of the contact is considered in the presence of liquid 6 POLES SPST (TC1) SPDT (TC2) B WHITE-N.O. LIGHT BLUE-N.C.

 Open the catalog to page 13

Archived catalogs

  1. Rapid level

    18  Pages

  2. IEG ATEX

    5  Pages

  3. LVC

    4  Pages

  4. RAPID LEVEL

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.