EX1250 STATIC ELIMINATOR BAR
2Pages

{{requestButtons}}

Catalog excerpts

EX1250 STATIC ELIMINATOR BAR - 1

EX1250 STATIC ELIMINATOR BAR The EX1250 Bar is a high performance static eliminator with ATEX certification for use in hazardous areas. Maximum ionisation performance in a hazardous area. > The EX1250 is part the Fraser 1250 family of static eliminators, which offer market-leading reliability and performance. > Stay-sharp etched emitters for better long term performance. Life 5 years +. Non-infectious. > Emitters at 15 mm pitch provide more ionisation and so better neutralisation. > Robust construction, but compact and easy to install. > Operating distance up to 150 mm. Best distance for high speeds and high charges 25 - 50 mm. > Washable and suitable for food, medical and pharmaceutical applications. > All electronic components are fully encapsulated for maximum reliability. > Certified for Zones 1 & 2. Gas group IIB (ethylene). Specification Length: Mounting: Cable: Safety: Environment: Any size from 120 mm to 6000 mm. Active length is 70 mm less than overall length. M4 x 20 mm hexagon studs slide in slot for mounting. 3 m of cable in protective nylon conduit is standard, longer lengths can be specified at time of order. Please check that 3 m is sufficient - the Power Unit must be positioned outside the hazardous area. High resistance in emitters for shockless operation. Location should be dry and oil free. 50° maximum temperature. 70% rH non-condensing max. Power Unit: HP EX Power Unit, must be positioned outside of the hazardous area. Options: Airboost for extending the range up to 500 mm.- see 1250 AB. Optional remote function monitoring showing status of high voltage and whether Bars require cleaning. 90° cable exit. Monitoring and alarm function on Power Unit to show that bars are operating correctly. Scotts Business Park, Bampton, Devon, GB, EX16 9DN T + 44 (0) 1398 331114 F + 44 (0) 1398 331411 E sales@fraser-antistatic.co.uk W www.fraser-antistatic.com © Fraser Anti-Static Techniques Ltd 2015

Open the catalog to page 1
EX1250 STATIC ELIMINATOR BAR - 2

Fixings: M4 x 20 LG Screws placed in slot under Bar. Dimensions in mm. ATEX Certification The details of the ATEX certification for the EX1250 Bar are: EX-1250 Static Eliminator BarYYYY/NNNN II 2G IIBT6 (-20°<Ta<+50°C) C€ YJ FRASER Anti-Static Techniques Fraser Anti-Static Techniques Ltd, Scotts Business Park, Bampton EX16 9DN UK www.fraser-antistatic.co.uk sales@fraser-antistatic.co.uk Explanation II Industrial equipments. 2 Equipment category: high protection. Suitable for zones 1 and 2. G Equipment used in potentially explosive atmospheres caused by presence of explosive gas, vapour...

Open the catalog to page 2

All Fraser Anti-Static Techniques catalogs and technical brochures

  1. 4300

    1 Pages

  2. 4400

    2 Pages

  3. 5500

    4 Pages

  4. 4200

    2 Pages

  5. 4125

    2 Pages

  6. 6000 IONTUBE

    2 Pages