Catalog excerpts
Specification Electrical Supply: 24V DC (21-28 V), maximum current required 0.5 A. M8 connector. The M8 x 4 core cable must be ordered separately - see cable options on page two. Remote Monitor: Sends 24 V signal to the PLC or other destination. This voltage is taken from the power to the Bar - no additional power source is required. The ultimate static eliminator for machinery manufacturers: compact, with built-in electronics, 24 V DC supply and very powerful performance. Static neutralisation to meet the requirements of high performance machinery. Integrated high voltage power supply, requires only a low voltage 24 V DC input. > Shockless, resistively coupled emitters made in tungsten for unlimited life. > Tested at speeds up to 2000 m/min > LED status indication: Bar OK: (green), fault (red). > Remote monitoring of operational status. > 100% coverage. Effective length = Overall length. No dead zone. > Standard M8 4 pin connector. > Available in two versions: 1. 3024 F - for distances from 25 mm to 100 mm. 2. 3024 L - for distances from 100 mm to 600 mm High Voltage Supply: Up to 11 kV supply integrated into Bar. Construction: FR-ABS Industrial grade extrusion, epoxy resin. Protection Classification: IP66. Fully sealed. Environment: Options: Weight: Standards: -10 to 55°C, 70% RH non-condensing. 90-250 V AC, Power Supply. Code: E3024-PSU 1.1 kg/m. CE, UL, CB. Scotts Business Park, Bampton, Devon, GB, EX16 9DN T + 44 (0) 1398 331114 F + 44 (0) 1398 331411 E sales@fraser-antistatic.co.uk W www.fraser-antistatic.com © Fraser Anti-Static Techniques Ltd 2015
Open the catalog to page 1Two Versions Two Versions 3024 F (fast) 3024 F > Ideal for fast-moving materials.in excess of 1000m/min. > Designed to cope with speeds > > > > Minimum fast-movingmm, available in 50 mm steps to 5 m. Ideal for length 250 materials. Operating distance from 25 mm to 100 mm. steps to 4.5m. Minimum length 250mm, available in 50mm 3024 L (long range) 3024 L > Ideal for applications with changing geometry. to 500mm. > Designed to cope with distances from 100mm > > > > Minimum applications with changing geometry. Ideal for length 300 mm, available in 100 mm steps to 5 m. Operating distance 100 -...
Open the catalog to page 2All Fraser Anti-Static Techniques catalogs and technical brochures
-
4300
1 Pages
-
4400
2 Pages
-
5500
4 Pages
-
4200
2 Pages
-
4125
2 Pages
-
EX1250 STATIC ELIMINATOR BAR
2 Pages
-
3850-SC IONSTORM BARS
2 Pages
-
3014 24 V DC IONISING BAR
2 Pages
-
3850sc_Ionstorm Ionising Bar
2 Pages
-
3024L 24V DC Ionising Bar
2 Pages
-
NEOS 12L Barre Ionisation
2 Pages
-
2010 IONISED AIR BLOWERS
2 Pages
-
6000 IONTUBE
2 Pages
-
4510 IONISED AIR JETS
2 Pages
-
101 & 201 STATIC DISCHARGERS
2 Pages
-
715 STATIC METER
2 Pages